You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Issue date 2004-11-19 - Catalogue <strong>AS</strong>-<strong>Interface</strong> 2004/2005<br />
Items Description<br />
<strong>AS</strong>-<strong>Interface</strong> - Training Kit<br />
11 <strong>AS</strong>-<strong>Interface</strong> Training Kit<br />
The <strong>AS</strong>-<strong>Interface</strong> training kit imparts the basics of topics relevant to the<br />
bus system, such as the master/slave principle, addressing topics, behavior<br />
of the system with failing nodes, and so on. Of course, more in-depth <strong>AS</strong>-<br />
<strong>Interface</strong> knowledge is also included.<br />
The core of the training kit is an <strong>AS</strong>-<strong>Interface</strong> master with enhanced control<br />
and PLC functionality (max. 16 kB command memory, with 8 kB registers,<br />
1024 timers, and 1024 counters), with which control programs can be processed<br />
over the <strong>AS</strong>-Intervace as a stand-alone.<br />
Along with the <strong>AS</strong>-<strong>Interface</strong> training kit, the trainee has a set of equipment<br />
available with which the functionality and possibilities of the <strong>AS</strong>-<strong>Interface</strong><br />
can be explored. The complete training kit includes a task collection comprising<br />
some 50 tasks, which increase in difficulty as the user progresses.<br />
It provides trainees with a step-by-step introduction to <strong>AS</strong>-<strong>Interface</strong>. For further<br />
support of the training, about 45 overhead slides are included, covering<br />
a range of topics. The commissioning software, along with the slides in<br />
PowerPoint ® format on CD, are included in the training kit.<br />
Order # with snap-in<br />
fasteners<br />
The <strong>AS</strong>-<strong>Interface</strong> training kit has been designed to be compatible with the<br />
SENSORIK training package. This means that either the kit or the breadboard<br />
can be used as work area. The sensors from the SENSORIK training<br />
package are compatible with the 2EA module.<br />
The training kit can be extended on request with gateways for connection<br />
to higher-level <strong>systems</strong>. This provides an opportunity to drive the <strong>AS</strong>-<strong>Interface</strong><br />
and the SENSORIK training kits directly from a bus system. Gateways<br />
for the PROFIBUS DP, InterBus, CANopen, DeviceNet, Modbus, and<br />
other bus <strong>systems</strong> are available on request. Included in the training kit is a<br />
professional commissioning software package including a converter. Using<br />
the commissioning software and the converter, any gateway can be addressed<br />
over the RS 232 interface of any PC. The gateways can also be<br />
driven as slaves from the corresponding field bus <strong>systems</strong>.<br />
For <strong>AS</strong>-<strong>Interface</strong> specification 2.1, there is a separate training kit. Using this<br />
training packages <strong>AS</strong>-<strong>Interface</strong> per specification 2.1, the particular features<br />
of the new <strong>AS</strong>-<strong>Interface</strong> geenration (for instance, A/B addressing, analogue<br />
value transmission) can be learned.<br />
Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany<br />
Pepperl+Fuchs Group Tel.: Germany +49 621 776-0 USA +1 330 4253555 Singapore +65 67799091 Internet http://www.pepperl-fuchs.com<br />
Order # with<br />
plugs<br />
<strong>AS</strong>-<strong>Interface</strong> training kit with standard master, without case 1 827 003 632 1 827 003 198<br />
1 <strong>AS</strong>-<strong>Interface</strong> Control Master with RS232 interface 1 827 003 672 1 827 003 972<br />
1 Power Extender (replaces the <strong>AS</strong>-<strong>Interface</strong> power supply 1 827 003 066 1 827 003 066<br />
2 Inductive <strong>AS</strong>-<strong>Interface</strong> <strong>Sensor</strong>s 1 827 003 071 1 827 003 971<br />
1 2EA module [for connection of two non-<strong>AS</strong>-<strong>Interface</strong>-ready sensors (E)<br />
and actuators (A)]<br />
1 827 003 644 1 827 003 644<br />
2 inductive two-wire sensors 1 827 003 532 1 827 003 932<br />
2 Test leads, yellow 1 827 003 523 1 827 003 523<br />
2 Test leads, black 1 827 003 143 1 827 003 143<br />
1 <strong>AS</strong>-<strong>Interface</strong> flat cable, yellow 1 827 003 068 1 827 003 068<br />
1 <strong>AS</strong>-<strong>Interface</strong> flat cable, black 1 827 003 069 1 827 003 069<br />
2<br />
Option<br />
Connector for connection of sensors/actuators to the 2EA module 1 827 003 070 1 827 003 070<br />
1 Bus monitor (hardware checker) including connector cables 1 827 003 658 1 827 003 658<br />
<strong>AS</strong>-<strong>Interface</strong> training kit with<br />
PROFIBUS DP gateway and<br />
PROFIBUS simulator<br />
<strong>AS</strong>-<strong>Interface</strong> training kit<br />
per specification 2.1<br />
with PROFIBUS DP gateway<br />
and PROFIBUS simulator<br />
345