UPR-05<br />

Issue date 2004-11-19 - Catalogue <strong>AS</strong>-<strong>Interface</strong> 2004/2005<br />

Universal Power Rail<br />

Order code<br />

UPR-05<br />

Universal Power Rail with DIN rail and<br />

cover, 5 leads<br />

Features<br />

Alternative power supply<br />

Nominal current 4 A<br />

Standard length 2 m, can be<br />

shortened to any length<br />

with 2 leads for power supply, 2 leads<br />

for bus connections and 1 lead for<br />

centralised error messages or HART<br />

signal transfer (with RPI-system)<br />

Accessories<br />

UPR-E<br />

End cap for UPR-03 und UPR-05<br />

Mechanischer Aufbau<br />

End cap UPR-E<br />

Technical data<br />

Electrical specifications<br />

Rated voltage 24 V DC<br />

Rated current 4 A<br />

Ambient conditions<br />

Ambient temperature -20 ... 60 °C (253 ... 333 K)<br />

Function<br />

Cover<br />

Slot mounted Power Rail<br />

2 leads for power supply<br />

1 lead for<br />

collective<br />

error message<br />

2 leads for bus<br />

connection<br />

Universal Power Rail<br />

Mount using M4<br />

screws with<br />

washers per<br />

DIN 125<br />

DIN rail<br />

35 mm x 15 mm<br />

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany<br />

Pepperl+Fuchs Group Tel.: Germany +49 621 776-0 USA +1 330 4253555 Singapore +65 67799091 Internet http://www.pepperl-fuchs.com<br />

UPR-05<br />

The universal Power Rail is a plastic insert that has been specifically designed to<br />

seat into the DIN rail. Devices that can be mounted on a standard rail in accordance<br />

with EN 50022, can easily be mounted on the DIN rail.<br />

The Power Rail has 2 leads for supplying the modules with power, 1 lead for centralised<br />

error messages and 2 leads for bus connection. These 2 leads are used on<br />

Remote Process <strong>Interface</strong>, for the internal bus system, for the transfer of digital information.<br />

The KF-series and Remote Process <strong>Interface</strong> devices are supplied with<br />

power via the 2 leads. Gold plated contacts are provided to ensure secure electrical<br />

contact. The UPR-05 do not feature "segmental" construction. Modules of any width<br />

can be mounted on these rails. This ensures that it will be possible to mount future<br />

component designs on the same rail. The TS35 type 12 end terminal is used as a<br />

termination when the devices are mounted vertically. The cover serves as a means<br />

of mechanical and electrical protection for exposed leads. It is possible to remove<br />

the installed Power Rail from the DIN rail using the UPR-E end cap.<br />

The universal Power Rail, the cover and the DIN rail are delivered in a standard<br />

length of 2 m and can be cut with a saw to any required length.<br />

Delivery package:<br />

Universal Power Rail, aluminium DIN rail, cover, 2 UPR-E end caps. The UPR-E<br />

end caps can be ordered separately (in packs of 10).<br />

Please use this standard type for new <strong>systems</strong>.<br />

335<br />

Masters and<br />

Gateways<br />

Power Supplies,<br />

Extender, Repeaters<br />

Safety at work<br />

I/O Modules<br />

Control cabinet<br />

I/O Modules<br />

Field application<br />

Analogue modules<br />

Other modules<br />

Inductive sensors<br />

Photoelectric<br />

sensors<br />

Rotary encoders<br />

Accessories