Sensor systems 2 AS-Interface

Sensor systems 2 AS-Interface Sensor systems 2 AS-Interface

18.01.2013 Views

U-G1FF Masters and Gateways Power Supplies, Extender, Repeaters Safety at work I/O Modules Control cabinet I/O Modules Field application Analogue modules Other modules Inductive sensors Photoelectric sensors Rotary encoders Accessories AS-Interface base Order code U-G1FF Base for connection to flat cable (EEMS; AS-Interface and external auxiliary power) Function The U-G1FF base allows to connect slaves with additional supply (EEMS) to AS-Interface. It has one connection type for AS-Interface and an other for the auxiliary power, which are not interconnected. For the mounting of an upper part (module or lid VAZ-DK- G1) the flat cable will be pressed in the contact prongs and so connected. Accessories VAZ-DK-G1 cover for bases -G1F- and -G1P- 316 Dimensions Electrical connection Technical data 18.5 18.5 + AS-Interface - External auxiliary power + - Ambient conditions Ambient temperature -25 ... 60 °C (248 ... 333 K) Storage temperature Mechanical specifications -40 ... 85 °C (233 ... 358 K) Protection degree IP67 according to EN 60529 (only in connection with module or cover) Connection Flat cable for AS-Interface and external power supply Dimensions about 80, 45, 20 mm (L, W, H) Mounting DIN rail or screw mounting U-G1FF Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany Pepperl+Fuchs Group Tel.: Germany +49 621 776-0 USA +1 330 4253555 Singapore +65 67799091 Internet http://www.pepperl-fuchs.com Ø 9.6 36 26 80 66 26 36 + - + - Contacts to module 31 45 Ø 5.3 Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

U-G1FFA Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005 AS-Interface base Order code U-G1FFA Base with addressing jack for connection to flat cable (EEMS; AS-Interface and external auxiliary power) Function The U-G1FFA base allows slaves to be connected to AS-Interface with additional supply (EEMS). It has one connection type to AS- Interface and an other one to auxiliary power, which are not interconnected. When mounting the upper part (module or cover VAZ-DK- G1) the flat cable will be pressed in the contact prongs and are thereby connected. Moreover, an integrated addressing jack can be used to configure the upper part in the wired AS-Interface network. In this case, the controller indicates "Alarm Config", since the slave is disconnected from the supply. After removing the addressing plug, the controller restarts independently. Accessories VAZ-DK-G1 cover for bases -G1F- and -G1P- Dimensions Electrical connection Technical data U-G1FFA General specifications Addressing Ambient conditions via addressing jack Ambient temperature -25 ... 60 °C (248 ... 333 K) Storage temperature Mechanical specifications -40 ... 85 °C (233 ... 358 K) Protection degree IP67 according to EN 60529 (only in connection with module or cover) Connection Flat cable for AS-Interface and external power supply Dimensions about 80, 45, 20 mm (L, W, H) Mounting DIN rail or screw mounting Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany Pepperl+Fuchs Group Tel.: Germany +49 621 776-0 USA +1 330 4253555 Singapore +65 67799091 Internet http://www.pepperl-fuchs.com 317 18.5 18.5 + AS-Interface - External auxiliary power + - Ø 9.6 ADDR 36 26 80 66 26 36 + - + - Contacts to module 31 Ø 5.3 45 Masters and Gateways Power Supplies, Extender, Repeaters Safety at work I/O Modules Control cabinet I/O Modules Field application Analogue modules Other modules Inductive sensors Photoelectric sensors Rotary encoders Accessories

U-G1FF<br />

Masters and<br />

Gateways<br />

Power Supplies,<br />

Extender, Repeaters<br />

Safety at work<br />

I/O Modules<br />

Control cabinet<br />

I/O Modules<br />

Field application<br />

Analogue modules<br />

Other modules<br />

Inductive sensors<br />

Photoelectric<br />

sensors<br />

Rotary encoders<br />

Accessories<br />

<strong>AS</strong>-<strong>Interface</strong> base<br />

Order code<br />

U-G1FF<br />

Base for connection to flat cable<br />

(EEMS; <strong>AS</strong>-<strong>Interface</strong> and external auxiliary<br />

power)<br />

Function<br />

The U-G1FF base allows to connect slaves<br />

with additional supply (EEMS) to <strong>AS</strong>-<strong>Interface</strong>.<br />

It has one connection type for <strong>AS</strong>-<strong>Interface</strong><br />

and an other for the auxiliary power,<br />

which are not interconnected. For the mounting<br />

of an upper part (module or lid VAZ-DK-<br />

G1) the flat cable will be pressed in the contact<br />

prongs and so connected.<br />

Accessories<br />

VAZ-DK-G1<br />

cover for bases -G1F- and -G1P-<br />

316<br />

Dimensions<br />

Electrical connection<br />

Technical data<br />

18.5 18.5<br />

+<br />

<strong>AS</strong>-<strong>Interface</strong><br />

-<br />

External<br />

auxiliary<br />

power<br />

+<br />

-<br />

Ambient conditions<br />

Ambient temperature -25 ... 60 °C (248 ... 333 K)<br />

Storage temperature<br />

Mechanical specifications<br />

-40 ... 85 °C (233 ... 358 K)<br />

Protection degree IP67 according to EN 60529<br />

(only in connection with module or cover)<br />

Connection Flat cable for <strong>AS</strong>-<strong>Interface</strong> and external power supply<br />

Dimensions about 80, 45, 20 mm (L, W, H)<br />

Mounting DIN rail or screw mounting<br />

U-G1FF<br />

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany<br />

Pepperl+Fuchs Group Tel.: Germany +49 621 776-0 USA +1 330 4253555 Singapore +65 67799091 Internet http://www.pepperl-fuchs.com<br />

Ø 9.6<br />

36<br />

26<br />

80<br />

66<br />

26<br />

36<br />

+ -<br />

+ -<br />

Contacts to module<br />

31<br />

45<br />

Ø 5.3<br />

Issue date 2004-11-19 - Catalogue <strong>AS</strong>-<strong>Interface</strong> 2004/2005