18.01.2013 Views

Sensor systems 2 AS-Interface

Sensor systems 2 AS-Interface

Sensor systems 2 AS-Interface

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Issue date 2004-11-19 - Catalogue <strong>AS</strong>-<strong>Interface</strong> 2004/2005<br />

RL28-55-V-B3B/73c<br />

Characteristic response curve<br />

Offset Y [mm]<br />

180<br />

160<br />

140<br />

120<br />

100<br />

80<br />

60<br />

40<br />

20<br />

y<br />

RL28-55-V<br />

0<br />

0 2 4 6 8 10<br />

H85<br />

Distance X [m]<br />

x<br />

C110-2<br />

H60<br />

H160<br />

F2000<br />

Relative received light strength<br />

Stability control > 3<br />

Stability control < 3<br />

x<br />

Reflector type:<br />

H85 (80 mm x 80 mm)<br />

C110_2 (ø = 84 mm)<br />

H60 (60 mm x 40 mm)<br />

F2000 (Foil, 100 mm x 100 mm)<br />

H160 (60 mm x 18 mm)<br />

100<br />

10<br />

3<br />

500 mm<br />

500 mm<br />

600 mm<br />

900 mm<br />

500 mm<br />

Stability control<br />

4,5 m<br />

Diagrams/notes<br />

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany<br />

Pepperl+Fuchs Group Tel.: Germany +49 621 776-0 USA +1 330 4253555 Singapore +65 67799091 Internet http://www.pepperl-fuchs.com 259<br />

6,0 m<br />

9,0 m<br />

11,0 m<br />

12,0 m<br />

H85<br />

C110-2<br />

H60<br />

H160<br />

F2000<br />

RL28-55-V<br />

1<br />

0 5 10 15<br />

Distance X [m]<br />

<strong>AS</strong>-<strong>Interface</strong> programming<br />

Address preset to 00, can be changed via Busmaster or programming devices<br />

IO-Code 3<br />

ID-Code A<br />

ID2 1<br />

Data bit<br />

Bitfunction<br />

D0 Switch output (0=light beam free, 1=light beam interrupted) applies to P1=0<br />

D1 Pre-fault indicator (0=alarm, 1=no alarm)<br />

D2 Test function (0=emitter ON, 1=emitter OFF)<br />

D3 not used<br />

Parameter bit<br />

Bitfunction (1/0)<br />

P0 not used<br />

P1 Light/dark-changeover switch (0=DS, 1=HS)<br />

P2 Time function IAB, 50 ms (0=time ON, 1=time OFF)<br />

P3not used<br />

Masters and<br />

Gateways<br />

Power Supplies,<br />

Extender, Repeaters<br />

Safety at work<br />

I/O Modules<br />

Control cabinet<br />

I/O Modules<br />

Field application<br />

Analogue modules<br />

Other modules<br />

Inductive sensors<br />

Photoelectric<br />

sensors<br />

Rotary encoders<br />

Accessories

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!