VBA-4E3A-CB-E/E2-P Masters and Gateways Power Supplies, Extender, Repeaters Safety at work I/O Modules Control cabinet I/O Modules Field application Analogue modules Other modules Inductive sensors Photoelectric sensors Rotary encoders Accessories AS-Interface printed circuit board Features A/B slave with extended addressing possibility for up to 62 slaves Integrated communication monitoring function Inputs and outputs short-circuit and overload proof No external power supply required Connection via pins 228 62 Spec 2.1 Order code VBA-4E3A-CB-E/E2-P Printed circuit board module 4 inputs / 3 outputs Dimensions 7 3.5 R2 3.2 Electrical connection AS-Interface + AS-Interface - 1 2 Indicating/operating means VBA-4E3A-CB-E/E2-P Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany Pepperl+Fuchs Group Tel.: Germany +49 621 776-0 USA +1 330 4253555 Singapore +65 67799091 Internet http://www.pepperl-fuchs.com 66 4 + 17 + 16 E1 13 E2 10 E3 7 E4 15 A1 12 A2 9 A3 6 A4 5 8 11 14 0 0 0 0 3 18 (free) (free) 18 NC 17 + 16 E1 15 A1 14 0 13 E2 12 A2 11 0 10 E3 9 A3 8 0 7 E4 6 A4 5 0 4 + 3 PROG 2 AS-i - 1 AS-i + Load 37.5 for 3-wire sensors Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005 AS-Interface printed circuit board Technical data General specifications Slave type Electrical specifications A/B slave Protection class III Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface Rated operational current Ie ≤ 20 mA (without sensors) Input Number/Type 4 inputs for mechanical contacts Supply from AS-Interface Voltage 21 ... 31 V Input current ≤ 8 mA (limited internally) Switching point 0 (unattenuated) ≤ 1 mA 1 (attenuated) ≥ 5 mA Output Number/Type 3 electronic outputs, PNP Supply from AS-Interface Current ≤ 80 mA per output, ≤ 80 mA total Voltage Programming instructions 21 ... 31 V Profile S-7.A.E IO code 7 ID code A ID2 code E Data bits (function via AS-Interface) input output D0 IN1 OUT1 D1 IN2 OUT2 D2 IN3 OUT3 D3 IN4 - Parameter bits (programmable via AS-i) function P0 not used P1 not used P2 not used P3 Ambient conditions not used Ambient temperature -25 ... 70 °C (248 ... 343 K) Storage temperature Mechanical specifications Length of housing Housing width Height of housing Diameter of housing -40 ... 70 °C (233 ... 343 K) Protection degree IP20 (completely fitted) according to EN 60529 Connection plug connector (pins) Function VBA-4E3A-CB-E/E2-P The VBA-4E3A-CB-E/E2-P AS-Interface coupling module is the circuit board solution for an AS-Interface slave. The module is ideal for integration into customer-specific electronics, e. g. keypads, actuators, etc. The circuit board is supplied by the AS-Interface. The inputs and outputs are short-circuit and overload-proof. Note: In the case of communication errors on the bus, the outputs are de-energised via an integrated watchdog. Pepperl+Fuchs can customise connectors and circuit board sizes e. g. for 2EA, 2E1A, ... models to meet your specific applications. Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany Pepperl+Fuchs Group Tel.: Germany +49 621 776-0 USA +1 330 4253555 Singapore +65 67799091 Internet http://www.pepperl-fuchs.com 229 Masters and Gateways Power Supplies, Extender, Repeaters Safety at work I/O Modules Control cabinet I/O Modules Field application Analogue modules Other modules Inductive sensors Photoelectric sensors Rotary encoders Accessories

Issue date 2004-11-19 - Catalogue <strong>AS</strong>-<strong>Interface</strong> 2004/2005<br />

<strong>AS</strong>-<strong>Interface</strong> printed circuit board<br />

Technical data<br />

General specifications<br />

Slave type<br />

Electrical specifications<br />

A/B slave<br />

Protection class III<br />

Rated operational voltage Ue 26.5 ... 31.6 V from <strong>AS</strong>-<strong>Interface</strong><br />

Rated operational current Ie ≤ 20 mA (without sensors)<br />

Input<br />

Number/Type 4 inputs for mechanical contacts<br />

Supply from <strong>AS</strong>-<strong>Interface</strong><br />

Voltage 21 ... 31 V<br />

Input current ≤ 8 mA (limited internally)<br />

Switching point<br />

0 (unattenuated) ≤ 1 mA<br />

1 (attenuated) ≥ 5 mA<br />

Output<br />

Number/Type 3 electronic outputs, PNP<br />

Supply from <strong>AS</strong>-<strong>Interface</strong><br />

Current ≤ 80 mA per output, ≤ 80 mA total<br />

Voltage<br />

Programming instructions<br />

21 ... 31 V<br />

Profile S-7.A.E<br />

IO code 7<br />

ID code A<br />

ID2 code E<br />

Data bits (function via <strong>AS</strong>-<strong>Interface</strong>) input output<br />

D0 IN1 OUT1<br />

D1 IN2 OUT2<br />

D2 IN3 OUT3<br />

D3 IN4 -<br />

Parameter bits (programmable via <strong>AS</strong>-i) function<br />

P0 not used<br />

P1 not used<br />

P2 not used<br />

P3<br />

Ambient conditions<br />

not used<br />

Ambient temperature -25 ... 70 °C (248 ... 343 K)<br />

Storage temperature<br />

Mechanical specifications<br />

Length of housing<br />

Housing width<br />

Height of housing<br />

Diameter of housing<br />

-40 ... 70 °C (233 ... 343 K)<br />

Protection degree IP20 (completely fitted) according to EN 60529<br />

Connection plug connector (pins)<br />

Function<br />

VBA-4E3A-CB-E/E2-P<br />

The VBA-4E3A-CB-E/E2-P <strong>AS</strong>-<strong>Interface</strong><br />

coupling module is the circuit board solution<br />

for an <strong>AS</strong>-<strong>Interface</strong> slave. The module is<br />

ideal for integration into customer-specific<br />

electronics, e. g. keypads, actuators, etc.<br />

The circuit board is supplied by the <strong>AS</strong>-<strong>Interface</strong>.<br />

The inputs and outputs are short-circuit<br />

and overload-proof.<br />

Note:<br />

In the case of communication errors on the<br />

bus, the outputs are de-energised via an<br />

integrated watchdog.<br />

Pepperl+Fuchs can customise connectors<br />

and circuit board sizes e. g. for 2EA, 2E1A,<br />

... models to meet your specific applications.<br />

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany<br />

Pepperl+Fuchs Group Tel.: Germany +49 621 776-0 USA +1 330 4253555 Singapore +65 67799091 Internet http://www.pepperl-fuchs.com 229<br />

Masters and<br />

Gateways<br />

Power Supplies,<br />

Extender, Repeaters<br />

Safety at work<br />

I/O Modules<br />

Control cabinet<br />

I/O Modules<br />

Field application<br />

Analogue modules<br />

Other modules<br />

Inductive sensors<br />

Photoelectric<br />

sensors<br />

Rotary encoders<br />

Accessories

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!