18.01.2013 Views

Sensor systems 2 AS-Interface

Sensor systems 2 AS-Interface

Sensor systems 2 AS-Interface

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

VBA-2E-KE2-I/U<br />

Masters and<br />

Gateways<br />

Power Supplies,<br />

Extender, Repeaters<br />

Safety at work<br />

I/O Modules<br />

Control cabinet<br />

I/O Modules<br />

Field application<br />

Analogue modules<br />

Other modules<br />

Inductive sensors<br />

Photoelectric<br />

sensors<br />

Rotary encoders<br />

Accessories<br />

<strong>AS</strong>-<strong>Interface</strong> analogue module<br />

Order code<br />

VBA-2E-KE2-I/U<br />

KE control cabinet module<br />

2 analogue inputs<br />

Features<br />

Housing with removable terminals<br />

Communication monitoring<br />

Addressing jack<br />

Supply of inputs external or from the<br />

module, as required<br />

Function indication for bus, internal<br />

and external sensor power supply,<br />

inputs<br />

204<br />

A D<br />

Spec 2.1<br />

Dimensions<br />

Electrical connection<br />

<strong>AS</strong>-<strong>Interface</strong> -<br />

<strong>AS</strong>-<strong>Interface</strong> +<br />

ADDR<br />

U AUX +<br />

U AUX -<br />

22.5 7<br />

85<br />

U+<br />

U-<br />

Plug-in jumpers<br />

Indicating/operating means<br />

2<br />

ON OFF<br />

EXT<br />

INT<br />

. ..<br />

VBA-2E-KE2-I/U<br />

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany<br />

Pepperl+Fuchs Group Tel.: Germany +49 621 776-0 USA +1 330 4253555 Singapore +65 67799091 Internet http://www.pepperl-fuchs.com<br />

µP<br />

Vor dem Öffnen alle Anschlüsse<br />

spannungsfrei schalten /<br />

de-energize all connections<br />

before opening<br />

1<br />

Entriegeln / unlock<br />

Auf BEIDEN Seiten drücken /<br />

press on BOTH sides<br />

2 Öffnen / open<br />

Oberteil bis zum STOPP<br />

herausziehen /<br />

pull upper part until STOP<br />

3 Schalter einstellen / set switches<br />

INT= <strong>Sensor</strong>versorgung aus <strong>AS</strong>-<strong>Interface</strong> /<br />

sensor supply from <strong>AS</strong>-<strong>Interface</strong><br />

EXT= <strong>Sensor</strong>versorgung extern /<br />

external sensor supply<br />

2 ON= Kanal 2 an / Channel 2 on<br />

2 OFF= Kanal 2 aus / Channel 2 off<br />

3<br />

1<br />

2<br />

4<br />

7<br />

5<br />

6<br />

8<br />

24V ext.<br />

Sig +<br />

Sig -<br />

0V ext.<br />

+<br />

Sig +<br />

Sig -<br />

-<br />

I1<br />

Sig+<br />

I2<br />

Sig+<br />

I1<br />

Sig-<br />

I2<br />

Sig-<br />

99<br />

2-wire 3-wire 4-wire<br />

+<br />

U+ U+<br />

-<br />

I/U I/U+<br />

24V<br />

ext.<br />

24V<br />

ext.<br />

PWR AUX<br />

ADDR<br />

U-<br />

I/U-<br />

U-<br />

Connections<br />

Input<br />

1 I1 Sig. +<br />

2 I1 Sig. -<br />

3 24 V ext.<br />

4 0 V ext.<br />

5 I2 Sig. +<br />

6 I2 Sig. -<br />

7 24 V ext.<br />

8 0 V ext.<br />

9 U1 Sig. +<br />

10 U1 Sig. -<br />

11 U2 Sig. +<br />

12 U2 Sig. -<br />

13 <strong>AS</strong>-<strong>Interface</strong> +<br />

14 <strong>AS</strong>-<strong>Interface</strong> -<br />

15 AUX +<br />

16 AUX -<br />

0V<br />

ext.<br />

0V<br />

ext.<br />

INPUT<br />

1 2 1 2 U<br />

OK<br />

I<br />

FAULT INT<br />

U1<br />

Sig+ U1<br />

Sig-<br />

U2<br />

Sig+<br />

U2<br />

Sig-<br />

<strong>AS</strong>-i+ <strong>AS</strong>-i- AUX+ AUX-<br />

Beschriftungsfeld /<br />

label field<br />

Issue date 2004-11-19 - Catalogue <strong>AS</strong>-<strong>Interface</strong> 2004/2005

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!