18.01.2013 Views

Sensor systems 2 AS-Interface

Sensor systems 2 AS-Interface

Sensor systems 2 AS-Interface

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

VBA-8E-G2-ZA<br />

Masters and<br />

Gateways<br />

Power Supplies,<br />

Extender, Repeaters<br />

Safety at work<br />

I/O Modules<br />

Control cabinet<br />

I/O Modules<br />

Field application<br />

Analogue modules<br />

Other modules<br />

Inductive sensors<br />

Photoelectric<br />

sensors<br />

Rotary encoders<br />

Accessories<br />

<strong>AS</strong>-<strong>Interface</strong> sensor module<br />

Features<br />

<strong>AS</strong>-<strong>Interface</strong> certificate<br />

Protection degree IP67<br />

Does require two addresses<br />

Double A/B slave with extended<br />

addressing possibility for up to 62<br />

slaves<br />

Double addressing jack<br />

Flat cable connection with cable<br />

piercing technique, variable flat cable<br />

guide<br />

Communication monitoring<br />

Inputs for 2-, 3-, and 4-wire sensors<br />

Supply for inputs from <strong>AS</strong>-<strong>Interface</strong><br />

Ground connection (FE) possible<br />

Function display for bus and inputs<br />

Detection of overload on sensor<br />

supply<br />

156<br />

U ®<br />

LISTED 57M3<br />

IND. CONT. EQ.<br />

CL<strong>AS</strong>S 2 CIRCUIT ONLY<br />

Order code<br />

VBA-8E-G2-ZA<br />

G2 flat module<br />

8 inputs (PNP)<br />

Dimensions<br />

18.7<br />

60<br />

36<br />

Electrical connection<br />

1<br />

2<br />

ADDR<br />

ADDR<br />

4 73.5 34.5<br />

PWR/<br />

FAULT<br />

PWR/<br />

FAULT<br />

Indicating/operating means<br />

1<br />

4<br />

1<br />

<strong>AS</strong>-<strong>Interface</strong> +<br />

<strong>AS</strong>-<strong>Interface</strong> -<br />

<strong>AS</strong>-<strong>Interface</strong> +<br />

<strong>AS</strong>-<strong>Interface</strong> -<br />

5<br />

2<br />

VBA-8E-G2-ZA<br />

Base is sold separately<br />

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany<br />

Pepperl+Fuchs Group Tel.: Germany +49 621 776-0 USA +1 330 4253555 Singapore +65 67799091 Internet http://www.pepperl-fuchs.com<br />

sensor +<br />

sensor -<br />

sensor +<br />

sensor -<br />

sensor +<br />

sensor -<br />

sensor +<br />

sensor -<br />

3 4<br />

5<br />

2 1<br />

IN1.2<br />

3 4<br />

5<br />

2 1<br />

IN1.4<br />

150<br />

3 4<br />

5<br />

2 1<br />

IN2.2<br />

1<br />

2<br />

4<br />

3<br />

5<br />

1<br />

2<br />

4<br />

3<br />

5<br />

1<br />

2<br />

4<br />

3<br />

5<br />

1<br />

2<br />

4<br />

3<br />

5<br />

3 4<br />

5<br />

2 1<br />

IN2.4<br />

3 2<br />

IN1.1<br />

4 1<br />

5<br />

3 2<br />

IN1.3<br />

4 1<br />

5<br />

3 2<br />

IN2.1<br />

4 1<br />

5<br />

3 2<br />

IN2.3<br />

IN1.1 IN1.3<br />

IN+ IN+<br />

IN2 IN4<br />

IN1 IN3<br />

IN- IN-<br />

FG FG<br />

IN1.2 IN1.4<br />

IN+ IN+<br />

(nc) (nc)<br />

IN2 IN4<br />

IN- IN-<br />

FG FG<br />

for 3-wire<br />

sensors<br />

for 3-wire<br />

sensors<br />

IN2.1 IN2.3<br />

IN+ IN+<br />

IN2 IN4<br />

IN1 IN3<br />

IN- IN-<br />

FG FG<br />

for 3-wire<br />

sensors<br />

IN2.2 IN2.4<br />

IN+ IN+<br />

(nc) (nc)<br />

IN2 IN4<br />

IN- IN-<br />

FG FG<br />

for 3-wire<br />

sensors<br />

Functional ground (FG)<br />

Ground connection via mounting base<br />

PWR/<br />

FAULT<br />

PWR/<br />

FAULT<br />

1<br />

1<br />

2<br />

2<br />

ADDR<br />

U®<br />

LISTED 57M3<br />

IND. CONT. EQ.<br />

CL<strong>AS</strong>S 2 CIRCUIT ONLY<br />

Issue date 2004-11-19 - Catalogue <strong>AS</strong>-<strong>Interface</strong> 2004/2005

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!