Sensor systems 2 AS-Interface
Sensor systems 2 AS-Interface Sensor systems 2 AS-Interface
VBA-4E3A-G2-ZA/EA2 Masters and Gateways Power Supplies, Extender, Repeaters Safety at work I/O Modules Control cabinet I/O Modules Field application Analogue modules Other modules Inductive sensors Photoelectric sensors Rotary encoders Accessories AS-Interface sensor-/actuator module Features AS-Interface certificate Protection degree IP67 A/B slave with extended addressing possibility for up to 62 slaves Addressing jack Flat cable connection with cable piercing technique, variable flat cable guide Communication monitoring Inputs for 2-, 3-, and 4-wire sensors Power supply of outputs from the external auxiliary voltage Supply for inputs from AS-Interface Ground connection (FE) possible Function display for bus, ext. auxiliary voltage, inputs and outputs Detection of overload on sensor supply Detection of output overload 152 U® 62 Spec 2.1 Order code VBA-4E3A-G2-ZA/EA2 G2 flat module 4 inputs (PNP) and 3 electronic outputs Dimensions 18,7 60 36 Electrical connection AS-Interface - AS-Interface + ADDR AUX AUX+ AUX- 4 73,5 34,5 PWR FAULT Sensor + Sensor - Sensor + Sensor - Indicating/operating means 1 3 4 5 5 2 2 1 IN1 IN2 4 3 1 3 4 5 5 2 2 1 IN3 IN4 4 VBA-4E3A-G2-ZA/EA2 Base is sold separately Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany Pepperl+Fuchs Group Tel.: Germany +49 621 776-0 USA +1 330 4253555 Singapore +65 67799091 Internet http://www.pepperl-fuchs.com 3 150 4 1 3 4 5 5 3 2 2 1 OUT1 OUT2 1 4 1 2 4 3 5 IN1 IN+ IN2 IN1 IN- FG IN3 IN+ IN4 IN3 IN- FG 1 2 4 3 5 IN2 IN+ (nc) IN2 IN- FG IN4 IN+ (nc) IN4 IN- FG 1 4 3 2 5 (nc) OUT1 OUT- OUT2 FG OUT1 1 4 3 2 5 (nc) OUT2 OUT- (nc) FG OUT2 1 4 3 2 5 5 (nc) OUT3 OUT- (nc) FG 3 2 OUT3 OUT3 for 3-wire sensors for 3-wire sensors Load Load Load Functional ground (FG) Ground connection via mounting base PWR FAULT ADDR AUX Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005
Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005 AS-Interface sensor-/actuator module Technical data General specifications Slave type Indicators/operating means A/B slave LED FAULT error display; LED red red: communication error or address is 0 red flashing: overload of sensor power supply or outputs LED PWR AS-Interface voltage; LED green LED AUX ext. auxiliary voltage UAUX; LED green LED IN switching state (input); 4 LED yellow LED OUT Electrical specifications switching state (output); 3 LED yellow Auxiliary voltage (output) UAUX 20 ... 30 V DC PELV (protection class 3 according to VDE 0106/IEC 364-4-41) Protection class III Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface Rated operational current Ie ≤ 40 mA (without sensors) / max. 240 mA Input Number/Type 4 inputs for 2- or 3-wire sensors (PNP), DC alternative 2 inputs for 4-wire sensors (PNP), DC Supply from AS-Interface Voltage 21 ... 31 V Current loading capacity ≤ 200 mA (T B ≤ 40 °C), ≤ 150 mA (T B ≤ 60 °C), overload-proof and short-circuit proof Input current ≤ 8 mA (limited internally) Switching point according to DIN EN 61131-2 (Type 2) 0 (unattenuated) ≤ 2 mA 1 (attenuated) ≥ 4 mA Output Number/Type 3 electronic outputs, PNP, overload and short-circuit proof Supply from external auxiliary voltage U AUX Current 4 A total, OUT 1, OUT 2: 2 A per output, OUT 3: 1.5 A Voltage ≥ (U AUX - 0,5 V) Programming instructions Profile S-7.A.2 IO code 7 ID code A ID1 code 7 ID2 code 2 Data bits (function via AS-Interface) input output D0 IN1 OUT1 D1 IN2 OUT2 D2 IN3 OUT3 D3 IN4 - Parameter bits (programmable via AS-i) function P0 not used P1 not used P2 not used P3 Ambient conditions not used Ambient temperature -25 ... 60 °C (248 ... 333 K) Storage temperature Mechanical specifications -25 ... 85 °C (248 ... 358 K) Protection degree IP67 according to EN 60529 Connection cable piercing method flat cable yellow/flat cable black inputs/outputs: M12 round connector Mass 150 g Mounting Mounting base Notes For 4-wire sensors, it is only possible to use plug-in slot IN1 or IN3 for inputs 1+2 or 3+4 (jumpered internally). Function VBA-4E3A-G2-ZA/EA2 The VBA-4E3A-G2-ZA/EA2 is an AS-Interface module with 4 Inputs and 3 outputs. Mechanical contacts (e. g. push buttons) as well as 2-, 3- and 4-wire sensors can be connected to the inputs. The outputs are electronic outputs, which can be collectively loaded with 24 V DC and 2 A or 1.5 A per output. The IP67 flat module is ideal for applications in the field. An addressing jack is integrated in the module. The connection for the sensors/actuators is via M12 x 1 screw connections. An LED is provided on the top of the module, for each channel, to indicate the current switching status. Similarly, an LED is provided to monitor the AS-Interface communication and to indicate that the module has the address 0. LEDs are also provided to indicate AS-Interface voltage and external power supply. The mounting plate U-G2FF is used as standard for the connection to the AS-Interface flat cable and the external 24 V DC supply. The specially designed base enables the user to connect flat cable from both sides. The device incorporates communication monitoring, which switches off power to the outputs if no communication has taken place on the AS-Interface line for longer than 40 ms. An overloading of the internal input supply or of the outputs is signalled to the AS-interface master via the "Peripheral fault" function. Communication via the AS-Interface remains intact. Note: The mounting base for the module is sold separately. Accessories VBP-HH1 Hand-held programming device VAZ-PK-1,5M-V1-G Connection cable module/hand-held programming device VAZ-FK-ED-G2 AS-Interface end seal for G2 modules Matching system components U-G2FF Mounting plate for connection to flat cable (AS-Interface and external auxiliary power) Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany Pepperl+Fuchs Group Tel.: Germany +49 621 776-0 USA +1 330 4253555 Singapore +65 67799091 Internet http://www.pepperl-fuchs.com 153 Masters and Gateways Power Supplies, Extender, Repeaters Safety at work I/O Modules Control cabinet I/O Modules Field application Analogue modules Other modules Inductive sensors Photoelectric sensors Rotary encoders Accessories
- Page 97 and 98: Issue date 2004-11-19 - Catalogue A
- Page 99 and 100: Issue date 2004-11-19 - Catalogue A
- Page 101 and 102: Issue date 2004-11-19 - Catalogue A
- Page 103 and 104: Issue date 2004-11-19 - Catalogue A
- Page 105 and 106: Issue date 2004-11-19 - Catalogue A
- Page 107 and 108: Issue date 2004-11-19 - Catalogue A
- Page 109 and 110: Issue date 2004-11-19 - Catalogue A
- Page 111 and 112: Issue date 2004-11-19 - Catalogue A
- Page 113 and 114: Issue date 2004-11-19 - Catalogue A
- Page 115 and 116: Issue date 2004-11-19 - Catalogue A
- Page 117 and 118: Issue date 2004-11-19 - Catalogue A
- Page 119 and 120: Issue date 2004-11-19 - Catalogue A
- Page 121 and 122: Issue date 2004-11-19 - Catalogue A
- Page 123 and 124: Issue date 2004-11-19 - Catalogue A
- Page 125 and 126: Issue date 2004-11-19 - Catalogue A
- Page 127 and 128: Issue date 2004-11-19 - Catalogue A
- Page 129 and 130: Issue date 2004-11-19 - Catalogue A
- Page 131 and 132: Issue date 2004-11-19 - Catalogue A
- Page 133 and 134: Issue date 2004-11-19 - Catalogue A
- Page 135 and 136: Issue date 2004-11-19 - Catalogue A
- Page 137 and 138: Issue date 2004-11-19 - Catalogue A
- Page 139 and 140: Issue date 2004-11-19 - Catalogue A
- Page 141 and 142: Issue date 2004-11-19 - Catalogue A
- Page 143 and 144: Issue date 2004-11-19 - Catalogue A
- Page 145 and 146: Issue date 2004-11-19 - Catalogue A
- Page 147: Issue date 2004-11-19 - Catalogue A
- Page 151 and 152: Issue date 2004-11-19 - Catalogue A
- Page 153 and 154: Issue date 2004-11-19 - Catalogue A
- Page 155 and 156: Issue date 2004-11-19 - Catalogue A
- Page 157 and 158: Issue date 2004-11-19 - Catalogue A
- Page 159 and 160: Issue date 2004-11-19 - Catalogue A
- Page 161 and 162: Issue date 2004-11-19 - Catalogue A
- Page 163 and 164: Issue date 2004-11-19 - Catalogue A
- Page 165 and 166: Issue date 2004-11-19 - Catalogue A
- Page 167 and 168: Issue date 2004-11-19 - Catalogue A
- Page 169 and 170: Issue date 2004-11-19 - Catalogue A
- Page 171 and 172: Issue date 2004-11-19 - Catalogue A
- Page 173 and 174: Issue date 2004-11-19 - Catalogue A
- Page 175 and 176: Issue date 2004-11-19 - Catalogue A
- Page 177 and 178: Issue date 2004-11-19 - Catalogue A
- Page 179 and 180: Issue date 2004-11-19 - Catalogue A
- Page 181 and 182: Issue date 2004-11-19 - Catalogue A
- Page 183 and 184: Issue date 2004-11-19 - Catalogue A
- Page 185 and 186: Issue date 2004-11-19 - Catalogue A
- Page 187 and 188: Issue date 2004-11-19 - Catalogue A
- Page 189 and 190: Issue date 2004-11-19 - Catalogue A
- Page 191 and 192: Issue date 2004-11-19 - Catalogue A
- Page 193 and 194: Issue date 2004-11-19 - Catalogue A
- Page 195 and 196: Issue date 2004-11-19 - Catalogue A
- Page 197 and 198: Issue date 2004-11-19 - Catalogue A
Issue date 2004-11-19 - Catalogue <strong>AS</strong>-<strong>Interface</strong> 2004/2005<br />
<strong>AS</strong>-<strong>Interface</strong> sensor-/actuator module<br />
Technical data<br />
General specifications<br />
Slave type<br />
Indicators/operating means<br />
A/B slave<br />
LED FAULT error display; LED red<br />
red: communication error or address is 0<br />
red flashing: overload of sensor power supply or outputs<br />
LED PWR <strong>AS</strong>-<strong>Interface</strong> voltage; LED green<br />
LED AUX ext. auxiliary voltage UAUX; LED green<br />
LED IN switching state (input); 4 LED yellow<br />
LED OUT<br />
Electrical specifications<br />
switching state (output); 3 LED yellow<br />
Auxiliary voltage (output) UAUX 20 ... 30 V DC PELV<br />
(protection class 3 according to VDE 0106/IEC 364-4-41)<br />
Protection class III<br />
Rated operational voltage Ue 26.5 ... 31.6 V from <strong>AS</strong>-<strong>Interface</strong><br />
Rated operational current Ie ≤ 40 mA (without sensors) / max. 240 mA<br />
Input<br />
Number/Type 4 inputs for 2- or 3-wire sensors (PNP), DC<br />
alternative 2 inputs for 4-wire sensors (PNP), DC<br />
Supply from <strong>AS</strong>-<strong>Interface</strong><br />
Voltage 21 ... 31 V<br />
Current loading capacity ≤ 200 mA (T B ≤ 40 °C),<br />
≤ 150 mA (T B ≤ 60 °C), overload-proof and short-circuit proof<br />
Input current ≤ 8 mA (limited internally)<br />
Switching point according to DIN EN 61131-2 (Type 2)<br />
0 (unattenuated) ≤ 2 mA<br />
1 (attenuated) ≥ 4 mA<br />
Output<br />
Number/Type 3 electronic outputs, PNP, overload and short-circuit proof<br />
Supply from external auxiliary voltage U AUX<br />
Current 4 A total,<br />
OUT 1, OUT 2: 2 A per output,<br />
OUT 3: 1.5 A<br />
Voltage ≥ (U AUX - 0,5 V)<br />
Programming instructions<br />
Profile S-7.A.2<br />
IO code 7<br />
ID code A<br />
ID1 code 7<br />
ID2 code 2<br />
Data bits (function via <strong>AS</strong>-<strong>Interface</strong>) input output<br />
D0 IN1 OUT1<br />
D1 IN2 OUT2<br />
D2 IN3 OUT3<br />
D3 IN4 -<br />
Parameter bits (programmable via <strong>AS</strong>-i) function<br />
P0 not used<br />
P1 not used<br />
P2 not used<br />
P3<br />
Ambient conditions<br />
not used<br />
Ambient temperature -25 ... 60 °C (248 ... 333 K)<br />
Storage temperature<br />
Mechanical specifications<br />
-25 ... 85 °C (248 ... 358 K)<br />
Protection degree IP67 according to EN 60529<br />
Connection cable piercing method<br />
flat cable yellow/flat cable black<br />
inputs/outputs: M12 round connector<br />
Mass 150 g<br />
Mounting Mounting base<br />
Notes<br />
For 4-wire sensors, it is only possible to use plug-in slot IN1 or IN3 for inputs 1+2 or 3+4<br />
(jumpered internally).<br />
Function<br />
VBA-4E3A-G2-ZA/EA2<br />
The VBA-4E3A-G2-ZA/EA2 is an <strong>AS</strong>-<strong>Interface</strong><br />
module with 4 Inputs and 3 outputs.<br />
Mechanical contacts (e. g. push buttons) as<br />
well as 2-, 3- and 4-wire sensors can be connected<br />
to the inputs. The outputs are electronic<br />
outputs, which can be collectively<br />
loaded with 24 V DC and 2 A or 1.5 A per<br />
output.<br />
The IP67 flat module is ideal for applications<br />
in the field. An addressing jack is integrated<br />
in the module.<br />
The connection for the sensors/actuators is<br />
via M12 x 1 screw connections. An LED is<br />
provided on the top of the module, for each<br />
channel, to indicate the current switching status.<br />
Similarly, an LED is provided to monitor<br />
the <strong>AS</strong>-<strong>Interface</strong> communication and to indicate<br />
that the module has the address 0.<br />
LEDs are also provided to indicate <strong>AS</strong>-<strong>Interface</strong><br />
voltage and external power supply.<br />
The mounting plate U-G2FF is used as<br />
standard for the connection to the <strong>AS</strong>-<strong>Interface</strong><br />
flat cable and the external 24 V DC supply.<br />
The specially designed base enables the<br />
user to connect flat cable from both sides.<br />
The device incorporates communication<br />
monitoring, which switches off power to the<br />
outputs if no communication has taken place<br />
on the <strong>AS</strong>-<strong>Interface</strong> line for longer than<br />
40 ms.<br />
An overloading of the internal input supply or<br />
of the outputs is signalled to the <strong>AS</strong>-interface<br />
master via the "Peripheral fault" function.<br />
Communication via the <strong>AS</strong>-<strong>Interface</strong> remains<br />
intact.<br />
Note:<br />
The mounting base for the module is sold<br />
separately.<br />
Accessories<br />
VBP-HH1<br />
Hand-held programming device<br />
VAZ-PK-1,5M-V1-G<br />
Connection cable module/hand-held programming<br />
device<br />
VAZ-FK-ED-G2<br />
<strong>AS</strong>-<strong>Interface</strong> end seal for G2 modules<br />
Matching system components<br />
U-G2FF<br />
Mounting plate for connection to flat cable<br />
(<strong>AS</strong>-<strong>Interface</strong> and external auxiliary<br />
power)<br />
Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany<br />
Pepperl+Fuchs Group Tel.: Germany +49 621 776-0 USA +1 330 4253555 Singapore +65 67799091 Internet http://www.pepperl-fuchs.com 153<br />
Masters and<br />
Gateways<br />
Power Supplies,<br />
Extender, Repeaters<br />
Safety at work<br />
I/O Modules<br />
Control cabinet<br />
I/O Modules<br />
Field application<br />
Analogue modules<br />
Other modules<br />
Inductive sensors<br />
Photoelectric<br />
sensors<br />
Rotary encoders<br />
Accessories