VAA-4A-K3-R Masters and Gateways Power Supplies, Extender, Repeaters Safety at work I/O Modules Control cabinet I/O Modules Field application Analogue modules Other modules Inductive sensors Photoelectric sensors Rotary encoders Accessories AS-Interface actuator module Features AS-Interface certificate Addressing jack Function display for outputs 4 potential-free switch-contacts 148 U ® Order code VAA-4A-K3-R Junction box module 4 relay outputs Dimensions 63 ø4 71 63 Electrical connection AS-Interface - AS-Interface - AS-Interface + AS-Interface + 2 4 Indicating/operating means 1 3 ADDR VAA-4A-K3-R Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany Pepperl+Fuchs Group Tel.: Germany +49 621 776-0 USA +1 330 4253555 Singapore +65 67799091 Internet http://www.pepperl-fuchs.com PWR OUT1 OUT2 OUT3 OUT4 75 20.5 39 5 6 13 7 8 15 9 10 17 11 12 19 OUT1o OUT1c OUT1 OUT2o OUT2c OUT2 OUT3o OUT3c OUT3 OUT4o OUT4c OUT4 Addressing jack Pwr AE Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005 AS-Interface actuator module Technical data General specifications Slave type Indicators/operating means Standard slave LED PWR AS-Interface voltage; LED green LED OUT Electrical specifications switching state (output); 4 LED yellow Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface Rated operational current Ie ≤ 40 mA Output Number/Type 4 relay outputs Contact loading 24 V DC, 500 mA per output, PELV (protection class 3 according to VDE 0106/IEC 364-4-41) Lifetime 3 x 10 7 Programming instructions switching cycles Profile S-8.0 IO code 8 ID code 0 Data bits (function via AS-Interface) input output D0 IN4 O4 D1 - OUT2 D2 - OUT3 D3 - OUT4 Parameter bits (programmable via AS-i) function P0 not used P1 not used P2 not used P3 Ambient conditions not used Ambient temperature -25 ... 60 °C (248 ... 333 K) Storage temperature Mechanical specifications -25 ... 85 °C (248 ... 358 K) Protection degree IP20 according to EN 60529 Connection terminal connection ≤ 2.5 mm 2 Mass 110 g Mounting DIN rail or screw mounting Function VAA-4A-K3-R The VAA-4A-K3-R AS-Interface coupling module is a junction box module with 4 relay outputs. The design of this module makes it particularly suitable for operation within a junction box. Its housing, only 39 mm thick, occupies little space in an installation. The VAA-4A-K3-R is installed by snapping it onto the 35 mm DIN rail per EN 50022. Screw terminals are available for connecting the outputs and the AS-Interface cable. These permit the connection of conductors of up to 2.5 mm 2 . Each output is switched via a relay, which can be loaded to 24 V DC and 0.5 A. The actuators connected to the module are supplied externally (see connection diagram). The module itself is supplied through the AS-Interface cable. The AS-Interface supply voltage is indicated by a green LED. The current switching state of each output is indicated by a yellow LED, located on the unit's front panel. Should there be an interruption to bus communications (e. g. failure of the master), the outputs maintain their current switch status while power is supplied. For address configuration before or after installation, a programming jack is integrated into the unit. It permits a connection to the hand-held programming device. Accessories VBP-HH1 Hand-held programming device VAZ-PK-1,5M-V1-G Connection cable module/hand-held programming device Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany Pepperl+Fuchs Group Tel.: Germany +49 621 776-0 USA +1 330 4253555 Singapore +65 67799091 Internet http://www.pepperl-fuchs.com 149 Masters and Gateways Power Supplies, Extender, Repeaters Safety at work I/O Modules Control cabinet I/O Modules Field application Analogue modules Other modules Inductive sensors Photoelectric sensors Rotary encoders Accessories

Issue date 2004-11-19 - Catalogue <strong>AS</strong>-<strong>Interface</strong> 2004/2005<br />

<strong>AS</strong>-<strong>Interface</strong> actuator module<br />

Technical data<br />

General specifications<br />

Slave type<br />

Indicators/operating means<br />

Standard slave<br />

LED PWR <strong>AS</strong>-<strong>Interface</strong> voltage; LED green<br />

LED OUT<br />

Electrical specifications<br />

switching state (output); 4 LED yellow<br />

Rated operational voltage Ue 26.5 ... 31.6 V from <strong>AS</strong>-<strong>Interface</strong><br />

Rated operational current Ie ≤ 40 mA<br />

Output<br />

Number/Type 4 relay outputs<br />

Contact loading 24 V DC, 500 mA per output, PELV<br />

(protection class 3 according to VDE 0106/IEC 364-4-41)<br />

Lifetime 3 x 10 7 Programming instructions<br />

switching cycles<br />

Profile S-8.0<br />

IO code 8<br />

ID code 0<br />

Data bits (function via <strong>AS</strong>-<strong>Interface</strong>) input output<br />

D0 IN4 O4<br />

D1 - OUT2<br />

D2 - OUT3<br />

D3 - OUT4<br />

Parameter bits (programmable via <strong>AS</strong>-i) function<br />

P0 not used<br />

P1 not used<br />

P2 not used<br />

P3<br />

Ambient conditions<br />

not used<br />

Ambient temperature -25 ... 60 °C (248 ... 333 K)<br />

Storage temperature<br />

Mechanical specifications<br />

-25 ... 85 °C (248 ... 358 K)<br />

Protection degree IP20 according to EN 60529<br />

Connection terminal connection ≤ 2.5 mm 2<br />

Mass 110 g<br />

Mounting DIN rail or screw mounting<br />

Function<br />

VAA-4A-K3-R<br />

The VAA-4A-K3-R <strong>AS</strong>-<strong>Interface</strong> coupling<br />

module is a junction box module with 4 relay<br />

outputs. The design of this module makes it<br />

particularly suitable for operation within a<br />

junction box. Its housing, only 39 mm thick,<br />

occupies little space in an installation. The<br />

VAA-4A-K3-R is installed by snapping it onto<br />

the 35 mm DIN rail per EN 50022.<br />

Screw terminals are available for connecting<br />

the outputs and the <strong>AS</strong>-<strong>Interface</strong> cable.<br />

These permit the connection of conductors<br />

of up to 2.5 mm 2 . Each output is switched via<br />

a relay, which can be loaded to 24 V DC and<br />

0.5 A.<br />

The actuators connected to the module are<br />

supplied externally (see connection diagram).<br />

The module itself is supplied through<br />

the <strong>AS</strong>-<strong>Interface</strong> cable. The <strong>AS</strong>-<strong>Interface</strong><br />

supply voltage is indicated by a green LED.<br />

The current switching state of each output is<br />

indicated by a yellow LED, located on the<br />

unit's front panel.<br />

Should there be an interruption to bus communications<br />

(e. g. failure of the master), the<br />

outputs maintain their current switch status<br />

while power is supplied.<br />

For address configuration before or after<br />

installation, a programming jack is integrated<br />

into the unit. It permits a connection to the<br />

hand-held programming device.<br />

Accessories<br />

VBP-HH1<br />

Hand-held programming device<br />

VAZ-PK-1,5M-V1-G<br />

Connection cable module/hand-held programming<br />

device<br />

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany<br />

Pepperl+Fuchs Group Tel.: Germany +49 621 776-0 USA +1 330 4253555 Singapore +65 67799091 Internet http://www.pepperl-fuchs.com 149<br />

Masters and<br />

Gateways<br />

Power Supplies,<br />

Extender, Repeaters<br />

Safety at work<br />

I/O Modules<br />

Control cabinet<br />

I/O Modules<br />

Field application<br />

Analogue modules<br />

Other modules<br />

Inductive sensors<br />

Photoelectric<br />

sensors<br />

Rotary encoders<br />

Accessories

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!