18.01.2013 Views

Sensor systems 2 AS-Interface

Sensor systems 2 AS-Interface

Sensor systems 2 AS-Interface

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

VAA-4E4A-KE-ZE/R<br />

Masters and<br />

Gateways<br />

Power Supplies,<br />

Extender, Repeaters<br />

Safety at work<br />

I/O Modules<br />

Control cabinet<br />

I/O Modules<br />

Field application<br />

Analogue modules<br />

Other modules<br />

Inductive sensors<br />

Photoelectric<br />

sensors<br />

Rotary encoders<br />

Accessories<br />

<strong>AS</strong>-<strong>Interface</strong> sensor-/actuator module<br />

Features<br />

Housing with removable, mechanical<br />

and colour coded terminals<br />

Communication monitoring<br />

Inputs for 2- and 3-wire sensors<br />

Isolated relay output<br />

Addressing jack<br />

Selectable supply to the sensors:<br />

External or from the module<br />

Function display for bus, internal<br />

sensor supply, inputs and outputs<br />

138<br />

U®<br />

Order code<br />

VAA-4E4A-KE-ZE/R<br />

KE switch cabinet module<br />

4 inputs (PNP) and 4 relay outputs<br />

Dimensions<br />

Electrical connection<br />

<strong>AS</strong>-<strong>Interface</strong> -<br />

<strong>AS</strong>-<strong>Interface</strong> +<br />

ADDR<br />

22.5 7<br />

99<br />

PWR<br />

FAULT<br />

Indicating/operating means<br />

VAA-4E4A-KE-ZE/R<br />

4 Inputs IN1 ... IN4<br />

I+<br />

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany<br />

Pepperl+Fuchs Group Tel.: Germany +49 621 776-0 USA +1 330 4253555 Singapore +65 67799091 Internet http://www.pepperl-fuchs.com<br />

OUT<br />

EXT<br />

INT IN<br />

EXT<br />

INT<br />

The plug connectors with dangerous contact<br />

voltage must not be connected or disconnected<br />

under power<br />

A T T E N T I O N<br />

Do not connect the terminals I+, IN and I- with<br />

any external potential when switch set to "INT"<br />

<strong>Sensor</strong> supply:<br />

INT = internal sensor supply (from <strong>AS</strong>-i)<br />

EXT = external sensor supply<br />

INT<br />

EXT<br />

IN<br />

I-<br />

4 Outputs O1 ... O4<br />

O1.4 ... O4.4<br />

O1.1 ... O4.1<br />

I- 1<br />

IN1<br />

I+ 1<br />

I- 2<br />

IN2<br />

I+ 2<br />

102<br />

Switch position<br />

"INT" "EXT"<br />

for 3-wire<br />

sensors<br />

I- 3<br />

IN3<br />

I+ 3<br />

I- 4<br />

IN4<br />

I+ 4<br />

1 2 3 4<br />

IN<br />

FAULT INT<br />

PWR<br />

ADDR<br />

1<br />

OUT<br />

O1.1<br />

O3.1<br />

<strong>AS</strong>-i+<br />

2<br />

O1.4<br />

O3.4<br />

<strong>AS</strong>-i-<br />

3 4<br />

O2.1 O2.4<br />

O4.1 O4.4<br />

U EXT<br />

label field<br />

for 3-wire<br />

sensors<br />

Issue date 2004-11-19 - Catalogue <strong>AS</strong>-<strong>Interface</strong> 2004/2005

Hooray! Your file is uploaded and ready to be published.