Sensor systems 2 AS-Interface

Sensor systems 2 AS-Interface Sensor systems 2 AS-Interface

18.01.2013 Views

VAA-2E-F85-V1 Masters and Gateways Power Supplies, Extender, Repeaters Safety at work I/O Modules Control cabinet I/O Modules Field application Analogue modules Other modules Inductive sensors Photoelectric sensors Rotary encoders Accessories AS-Interface emergency off button Features Protection degree IP65 and IP69k Outwit-proof according to ISO 13850/EN 418 2-channel, compelled connected TÜV-approval for system components is available Function When used in accordance with conditions in combination with an AS-Interface safety monitor, this AS-Interface EMERGENCY OFF makes it possible to operate personal protection equipment. Accessories VAZ-F85-SH Actuating protection 104 SAFETY AT WORK Order code VAA-2E-F85-V1 AS-Interface emergency off button ü BG-Pr fZert 01097 Dimensions Electrical connection Technical data 58.6 72 VAA-2E-F85-V1 General specifications Slave type Electrical specifications Standard slave Protection class III Rated operational voltage Ue 26.5 ... 31.6 V from AS-Interface Rated operational current Ie Input ≤ 20 mA Number/Type 2 NC Safety function with positive opening operation in accordance with IEC/EN 60947-5-1 Reset on pulling Supply Programming instructions from AS-Interface Profile S-7.B.E IO code 7 ID code B ID1 code 0 ID2 code E Data bits (function via AS-Interface) input output D0 dyn. safety code S1 - D1 dyn. safety code S1 - D2 dyn. safety code S2 - D3 dyn. safety code S2 - Parameter bits (programmable via AS-i) function P0 not used P1 not used P2 not used P3 Ambient conditions not used Ambient temperature -25 ... 55 °C (248 ... 328 K) Storage temperature Mechanical specifications -25 ... 85 °C (248 ... 358 K) Protection degree IP65 according to EN 60529 and IP69k Connection M12 round connector Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany Pepperl+Fuchs Group Tel.: Germany +49 621 776-0 USA +1 330 4253555 Singapore +65 67799091 Internet http://www.pepperl-fuchs.com 66.5 2 80 ø4.5 AS-Interface + 1 3 AS-Interface - 4 56 20 Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005

Issue date 2004-11-19 - Catalogue AS-Interface 2004/2005 Notes Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany Pepperl+Fuchs Group Tel.: Germany +49 621 776-0 USA +1 330 4253555 Singapore +65 67799091 Internet http://www.pepperl-fuchs.com 105 Masters and Gateways Power Supplies, Extender, Repeaters Safety at work I/O Modules Control cabinet I/O Modules Field application Analogue modules Other modules Inductive sensors Photoelectric sensors Rotary encoders Accessories

VAA-2E-F85-V1<br />

Masters and<br />

Gateways<br />

Power Supplies,<br />

Extender, Repeaters<br />

Safety at work<br />

I/O Modules<br />

Control cabinet<br />

I/O Modules<br />

Field application<br />

Analogue modules<br />

Other modules<br />

Inductive sensors<br />

Photoelectric<br />

sensors<br />

Rotary encoders<br />

Accessories<br />

<strong>AS</strong>-<strong>Interface</strong> emergency off button<br />

Features<br />

Protection degree IP65 and IP69k<br />

Outwit-proof according to<br />

ISO 13850/EN 418<br />

2-channel, compelled connected<br />

TÜV-approval for system<br />

components is available<br />

Function<br />

When used in accordance with conditions in<br />

combination with an <strong>AS</strong>-<strong>Interface</strong> safety<br />

monitor, this <strong>AS</strong>-<strong>Interface</strong> EMERGENCY<br />

OFF makes it possible to operate personal<br />

protection equipment.<br />

Accessories<br />

VAZ-F85-SH<br />

Actuating protection<br />

104<br />

SAFETY AT WORK<br />

Order code<br />

VAA-2E-F85-V1<br />

<strong>AS</strong>-<strong>Interface</strong> emergency off button<br />

ü<br />

BG-Pr fZert<br />

01097<br />

Dimensions<br />

Electrical connection<br />

Technical data<br />

58.6<br />

72<br />

VAA-2E-F85-V1<br />

General specifications<br />

Slave type<br />

Electrical specifications<br />

Standard slave<br />

Protection class III<br />

Rated operational voltage Ue 26.5 ... 31.6 V from <strong>AS</strong>-<strong>Interface</strong><br />

Rated operational current Ie Input<br />

≤ 20 mA<br />

Number/Type 2 NC<br />

Safety function with positive opening operation in accordance<br />

with IEC/EN 60947-5-1 Reset on pulling<br />

Supply<br />

Programming instructions<br />

from <strong>AS</strong>-<strong>Interface</strong><br />

Profile S-7.B.E<br />

IO code 7<br />

ID code B<br />

ID1 code 0<br />

ID2 code E<br />

Data bits (function via <strong>AS</strong>-<strong>Interface</strong>) input output<br />

D0 dyn. safety code S1 -<br />

D1 dyn. safety code S1 -<br />

D2 dyn. safety code S2 -<br />

D3 dyn. safety code S2 -<br />

Parameter bits (programmable via <strong>AS</strong>-i) function<br />

P0 not used<br />

P1 not used<br />

P2 not used<br />

P3<br />

Ambient conditions<br />

not used<br />

Ambient temperature -25 ... 55 °C (248 ... 328 K)<br />

Storage temperature<br />

Mechanical specifications<br />

-25 ... 85 °C (248 ... 358 K)<br />

Protection degree IP65 according to EN 60529 and IP69k<br />

Connection M12 round connector<br />

Subject to reasonable modifications due to technical advances. Copyright Pepperl+Fuchs, Printed in Germany<br />

Pepperl+Fuchs Group Tel.: Germany +49 621 776-0 USA +1 330 4253555 Singapore +65 67799091 Internet http://www.pepperl-fuchs.com<br />

66.5<br />

2<br />

80<br />

ø4.5<br />

<strong>AS</strong>-<strong>Interface</strong> +<br />

1<br />

3<br />

<strong>AS</strong>-<strong>Interface</strong> -<br />

4<br />

56<br />

20<br />

Issue date 2004-11-19 - Catalogue <strong>AS</strong>-<strong>Interface</strong> 2004/2005

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!