XIX Sympozjum Srodowiskowe PTZE - materialy.pdf
XIX Sympozjum Srodowiskowe PTZE - materialy.pdf XIX Sympozjum Srodowiskowe PTZE - materialy.pdf
XIX Sympozjum PTZE, Worliny 2009 The Pacemaker Patients Education – Initial Project Review Pacemaker wearers need to be educated not only in living with disease, but also in living with device (in awareness of threats). The number of people (cardiac implant wearers) whose work or live exposes them to artificial (man-made) electromagnetic fields is growing. The awareness of coexistence EMF sources within the healthcare and everyday environment is rising. That information can be available through specialized webpage. System (ePacemaker) described a problem of exposing pacemaker wearers (cardiac pacemaker) to EMF. The basic specification of education cardiac device implant wearers about electromagnetism and specially electromagnetic interferences are: (1) provide information about device malfunction and its consequences, (2) include family members in education. The initial version of ePacemaker system will allow medical staff to show patients educational materials featuring problem of exposing pacemaker wearers to electromagnetic field. This will provide patients with a better understanding of interaction pacemaker-EMF. Summary Trend in pacemakers malfunction rates due to EMI in real-life situation that is the problem. Patients are interested in estimation of risk and they want to know the relation between the level of risk and technical parameters of exposure is a prevalent aspect of the everyday life. Authors suggest future plans focusing on realization specialized system (as a part of specialized webpage). Project will be focused on popularization knowledge of EMF interference. This will provide patients with a better understanding of kind of interaction pacemaker-EMF. References [1] http://www.americanheart.org/presenter.jhtml?identifier=33, accessed: March 15th, 2009. [2] http://www.cardiologyassociatespc.com/handler.cfm?event=practice,template&cpid=5929, accessed: March 15 th , 2009. [3] http://www.nursingcenter.com/library/JournalArticle.asp?Article_ID=841499, accessed: March 15 th , 2009. [4] http://mkt.medselfed.com/asp/prodDisplay.asp?prodId=399&partnerId=mkt&id=&cachedate= &emailId=&affId=&campId=&hideNav= , accessed: March 15 th , 2009. [5] http://www.nlm.nih.gov/medlineplus/tutorials/pacemakers/htm/index.htm, accessed: March 15 th , 2009. [6] http://www.nlm.nih.gov/medlineplus/pacemakersandimplantabledefibrillators.html, accessed: March 15 th , 2009. [7] http://www.nlm.nih.gov/medlineplus/tutorials/pacemakers/htm/_no_50_no_0.htm, accessed: March 15 th , 2009. 138
XIX Sympozjum PTZE, Worliny 2009 JAKOŚĆ OBRAZOWANIA W TOMOGRAFII WIELOŚCIEŻKOWEJ Krzysztof Polakowski 1 , Stefan F. Filipowicz 2, 4 , Jan Sikora 3, 4 , Tomasz Rymarczyk 4 Wstęp 1 Politechnika Warszawska, Instytut Maszyn Elektrycznych, Pl. Politechniki 1, 00-661 Warszawa, e-mail: kp@zkue.ime.pw.edu.pl, 2 Politechnika Warszawska, Instytut Elektrotechniki Teoretycznej I Technik Informacyjnych, Pl. Politechniki 1, 00-661 Warszawa, e-mail: 2xf@nov.iem.pw.edu.pl, 3 Politechnika Lubelska, Wydział Elektroniki, Nadbystrzycka 38d, 20-618 Lublin, e-mail: j.sikora@iel.waw.pl, 4 Instytut Elektrotechniki, ul. Pożaryskiego 28, 04-703 Warszawa, e-mail: Tomasz@rymarczyk.com Praca jest kolejnym etapem tworzenia algorytmów konstrukcji obrazu w tomografii wielościeżkowej (ultradźwiękowej, optycznej itp.) wykorzystującej algorytmy z grupy metod algebraicznych, bazujących na aproksymacji funkcji przez szeregi o skończonej długości. Badany obszar dyskretyzowany jest w postaci kwadratowych komórek, które traktowane są, jako piksele w odtwarzanym obrazie [1, 2]. Wyniki symulacji komputerowej W pracy zamieszczono wyniki obrazowania obiektów obrazujących przepływ o skomplikowanym profilu. Odtworzenie profilu przepływu w badanej płaszczyźnie polegało na wyznaczeniu estymat skończonego zbioru nieznanych wartości, które można określić, jako f(x, y). W przypadku tomografii, na podstawie pomiarów impulsów penetrujących badany obszar sygnałów można uzyskać scałkowane wartości badanego parametru na drogach i-tych ścieżek pomiarowych (zwanych promieniami), które są określane rzutami (lub projekcjami).[3, 4]. Na rys. 1a przedstawiono modelowany profil a zarazem obraz uzyskany w wyniku symulacji, który dokładnie odzwierciedla założenia. Eksperyment numeryczny został przeprowadzony na niezaszumionych danych syntetycznych bez filtracji. Algorytm konstrukcji obrazu bazuje na nadokreślonym układzie równań, umożliwiającym uzyskanie precyzyjnego rozwiązania [5]. Do uzyskania prawidłowego wyniku najwygodniej jest skorzystać z wykresu ( k ) r = f ( k ) f , gdzie k są wartościami osobliwymi, który jest przedstawiony na rys. 2. { } 139
- Page 88 and 89: XIX Sympozjum PTZE, Worliny 2009 Th
- Page 90 and 91: XIX Sympozjum PTZE, Worliny 2009 sp
- Page 92 and 93: XIX Sympozjum PTZE, Worliny 2009 hu
- Page 94 and 95: XIX Sympozjum PTZE, Worliny 2009 Fi
- Page 96 and 97: Conclusions XIX Sympozjum PTZE, Wor
- Page 98 and 99: XIX Sympozjum PTZE, Worliny 2009 Th
- Page 100 and 101: XIX Sympozjum PTZE, Worliny 2009 an
- Page 102 and 103: XIX Sympozjum PTZE, Worliny 2009 [3
- Page 104 and 105: H_zob 2. TFM geometry optimization
- Page 107 and 108: XIX Sympozjum PTZE, Worliny 2009 RE
- Page 109 and 110: XIX Sympozjum PTZE, Worliny 2009 BR
- Page 111 and 112: XIX Sympozjum PTZE, Worliny 2009 DI
- Page 113 and 114: XIX Sympozjum PTZE, Worliny 2009 NO
- Page 115 and 116: XIX Sympozjum PTZE, Worliny 2009 DY
- Page 117 and 118: XIX Sympozjum PTZE, Worliny 2009 IN
- Page 119: References XIX Sympozjum PTZE, Worl
- Page 122 and 123: XIX Sympozjum PTZE, Worliny 2009 ty
- Page 125 and 126: XIX Sympozjum PTZE, Worliny 2009 WY
- Page 127: 1000 100 10 H-Field 3D [nT] E-Field
- Page 130 and 131: Rys. 1. Rozpatrywany model (rysunek
- Page 132 and 133: The usual stimulation is done by ma
- Page 134 and 135: Literatura XIX Sympozjum PTZE, Worl
- Page 136 and 137: XIX Sympozjum PTZE, Worliny 2009 80
- Page 140 and 141: a) b) 45 40 35 30 25 20 15 10 5 5 1
- Page 142 and 143: XIX Sympozjum PTZE, Worliny 2009 Th
- Page 144 and 145: u1 i1 N1 u2 i2 N2 um i m Nm XIX Sym
- Page 147 and 148: XIX Sympozjum PTZE, Worliny 2009 A
- Page 149 and 150: Introduction XIX Sympozjum PTZE, Wo
- Page 151 and 152: XIX Sympozjum PTZE, Worliny 2009 IM
- Page 153 and 154: Introduction XIX Sympozjum PTZE, Wo
- Page 155 and 156: XIX Sympozjum PTZE, Worliny 2009 PE
- Page 157 and 158: XIX Sympozjum PTZE, Worliny 2009 WP
- Page 159: Tmax(K) 24 20 16 12 8 4 0 0.0004 0.
- Page 162 and 163: XIX Sympozjum PTZE, Worliny 2009 Ws
- Page 164 and 165: XIX Sympozjum PTZE, Worliny 2009 ce
- Page 166 and 167: XIX Sympozjum PTZE, Worliny 2009 Za
- Page 168 and 169: XIX Sympozjum PTZE, Worliny 2009
- Page 170 and 171: XIX Sympozjum PTZE, Worliny 2009 ch
- Page 173 and 174: XIX Sympozjum PTZE, Worliny 2009 KO
- Page 175: XIX Sympozjum PTZE, Worliny 2009 PO
- Page 178 and 179: XIX Sympozjum PTZE, Worliny 2009 an
<strong>XIX</strong> <strong>Sympozjum</strong> <strong>PTZE</strong>, Worliny 2009<br />
JAKOŚĆ OBRAZOWANIA<br />
W TOMOGRAFII WIELOŚCIEŻKOWEJ<br />
Krzysztof Polakowski 1 , Stefan F. Filipowicz 2, 4 , Jan Sikora 3, 4 , Tomasz Rymarczyk 4<br />
Wstęp<br />
1 Politechnika Warszawska, Instytut Maszyn Elektrycznych,<br />
Pl. Politechniki 1, 00-661 Warszawa, e-mail: kp@zkue.ime.pw.edu.pl,<br />
2 Politechnika Warszawska, Instytut Elektrotechniki Teoretycznej I Technik Informacyjnych,<br />
Pl. Politechniki 1, 00-661 Warszawa, e-mail: 2xf@nov.iem.pw.edu.pl,<br />
3 Politechnika Lubelska, Wydział Elektroniki,<br />
Nadbystrzycka 38d, 20-618 Lublin, e-mail: j.sikora@iel.waw.pl,<br />
4 Instytut Elektrotechniki,<br />
ul. Pożaryskiego 28, 04-703 Warszawa, e-mail: Tomasz@rymarczyk.com<br />
Praca jest kolejnym etapem tworzenia algorytmów konstrukcji obrazu w tomografii wielościeżkowej<br />
(ultradźwiękowej, optycznej itp.) wykorzystującej algorytmy z grupy metod algebraicznych,<br />
bazujących na aproksymacji funkcji przez szeregi o skończonej długości. Badany<br />
obszar dyskretyzowany jest w postaci kwadratowych komórek, które traktowane są, jako piksele<br />
w odtwarzanym obrazie [1, 2].<br />
Wyniki symulacji komputerowej<br />
W pracy zamieszczono wyniki obrazowania obiektów obrazujących przepływ o skomplikowanym<br />
profilu. Odtworzenie profilu przepływu w badanej płaszczyźnie polegało na wyznaczeniu<br />
estymat skończonego zbioru nieznanych wartości, które można określić, jako f(x, y).<br />
W przypadku tomografii, na podstawie pomiarów impulsów penetrujących badany obszar<br />
sygnałów można uzyskać scałkowane wartości badanego parametru na drogach i-tych ścieżek<br />
pomiarowych (zwanych promieniami), które są określane rzutami (lub projekcjami).[3, 4].<br />
Na rys. 1a przedstawiono modelowany profil a zarazem obraz uzyskany w wyniku symulacji,<br />
który dokładnie odzwierciedla założenia. Eksperyment numeryczny został przeprowadzony na<br />
niezaszumionych danych syntetycznych bez filtracji. Algorytm konstrukcji obrazu bazuje na nadokreślonym<br />
układzie równań, umożliwiającym uzyskanie precyzyjnego rozwiązania [5].<br />
Do uzyskania prawidłowego wyniku najwygodniej jest skorzystać z wykresu<br />
( k )<br />
r = f<br />
( k )<br />
f , gdzie k są wartościami osobliwymi, który jest przedstawiony na rys. 2.<br />
{ }<br />
139