6 Probe 3 XL Probe 3 XL has all the properties of Probe 3. Furthermore, it is equipped with a wider drainage lumen for use with blood in the CSF. Intraparenchymal Probes Probe 3 PN Probe 3 PN measures intraparenchymal pressure. Probe 3 PN is placed in the parenchyma through a burr hole. Probe 3 PN can be tunneled with the aid of the tunneling tool ZBH 13.001.03. Probe 3 PN is fixed to the skin with a suturing flap. Probe 3 PS Probe 3 PS measures intraparenchymal pressure. Probe 3 PS is placed in the parenchyma through a bolt that is screwed into the cranial bone. A compressionscrew connection fixes the probe in the bolt and tightens it. Description REF Probe 3 XL SND 13.1.13XL/FV533 Technical Information Material Polyurethane Filling volume .05 - .1 cc Outside diameter 3 mm Inside diameter for 1.6 mm Drainage Dual lumen length 130 mm with radiopaque stripe Single lumen length 150 mm (Drainage) Single lumen length 1370 mm (Air-System) Depth marks 50 - 100 mm Duration of use Short term not more than 30 days Shelf life 3 years Double packed EO sterile For single use Latex free Description REF Probe 3 PN SND 13.1.53/FV534 Technical Information Material Polyurethane Filling volume .05 - .1 cc Diameter 1.3 mm Length 1500 mm Air Tube radiopaque Depth marks 30 mm 40 mm Duration of use Short term not more than 30 days Shelf life 3 years Double packed EO sterile For single use Latex free Description REF Probe 3 PS SND 13.1.63/FV535 Technical Information Material Polyurethane Filling volume .05 - .1 cc Diameter 1.3 mm Length 1500 mm Air Tube radiopaque Duration of use Short term not more than 30 days Shelf life 3 years Double packed EO sterile For single use Latex free
Probe 3 PN with Trocar The trocar is used to tunnel the distal end of the probe. It is equipped with a conic hole to take up the connector of the airtube . The probe has two depth marks. Probe 3 PN with trocar measures intraparenchymal pressure. The probe is placed in the parenchyma through a burr hole. Probe 3 PN with trocar is tunneled by means of the trocar in a surgically correct fashion away from the burr hole. To facilitate the tunneling, the air tube is equipped with a connector, that is taken up by the trocar. The extension is used to connect the probe with the ICP-Monitor. The slitted suturing wing is used for the fixation to the skin. After tunneling, the trocar is removed and the air tube is connected to the ICP-Monitor by means of the extension. Probe 3 PN is fixed to the skin with a suturing wing. The nut secures the connection of the probe to the extension. Description REF Probe 3 PN with Trocar SND 13.1.54 Technical Information Material Polyurethane Filling volume .05 - .1 cc Diameter 1.3 mm Length 1500 mm Air Tube radiopaque Depth marks 30 mm 40 mm Duration of use Short term not more than 30 days Shelf life 3 years Double packed EO sterile For single use Latex free 7
- Page 1 and 2: Spiegelberg: ICP-Products Technolog
- Page 3 and 4: ICP Monitoring With the Air-Pouch M
- Page 5: Epidural Probes Probe 1 Probe 1 is
- Page 9 and 10: Tunnelable Antimicrobial Intraventr
- Page 11 and 12: Scientific Information about Silver
- Page 13 and 14: Trial Version The software will wor
- Page 15 and 16: Connecting Cables and Accessories T
Probe 3 PN with Trocar<br />
The trocar is used to<br />
tunnel the distal end of<br />
the probe. It is<br />
equipped with a conic<br />
hole to take up the<br />
connector of the airtube<br />
.<br />
The probe has two<br />
depth marks.<br />
Probe 3 PN with trocar measures<br />
intraparenchymal pressure.<br />
The probe is placed in the parenchyma<br />
through a burr hole.<br />
Probe 3 PN with trocar is tunneled by<br />
means of the trocar in a surgically<br />
correct fashion away from the burr<br />
hole. To facilitate the tunneling, the<br />
air tube is equipped with a<br />
connector, that is taken up by the<br />
trocar.<br />
The extension is used to<br />
connect the probe with<br />
the <strong>ICP</strong>-Monitor.<br />
The slitted suturing wing<br />
is used for the fixation to<br />
the skin.<br />
After tunneling, the trocar is removed<br />
and the air tube is connected to the<br />
<strong>ICP</strong>-Monitor by means of the<br />
extension.<br />
Probe 3 PN is fixed to the skin with a<br />
suturing wing.<br />
The nut secures the<br />
connection of the probe<br />
to the extension.<br />
Description REF<br />
Probe 3 PN with Trocar SND 13.1.54<br />
Technical Information<br />
Material Polyurethane<br />
Filling volume .05 - .1 cc<br />
Diameter 1.3 mm<br />
Length 1500 mm<br />
Air Tube radiopaque<br />
Depth marks 30 mm<br />
40 mm<br />
Duration of use Short term<br />
not more than 30<br />
days<br />
Shelf life 3 years<br />
Double packed<br />
EO sterile<br />
For single use<br />
Latex free<br />
7