<strong>DVZ</strong>-ALPB<br />

Maintenance<br />

WARNING<br />

Metering pumps and their peripheral equipment may only be<br />

serviced by trained and authorised personnel!<br />

Service intervals: every quarter of a year!<br />

Please note:<br />

Service internval: every quater of a year!<br />

Shorter intervals for heavy duty operation (e.g continuous<br />

operation)!<br />

The maintenance of the <strong>DVZ</strong> metering pumps is limited to<br />

checking<br />

The liquid end screws (fitting tightly, 4.5 - 5 Nm)<br />

The discharge lines (fitting tightly)<br />

The head and suction valves (fitting tightly)<br />

The bleed valve for the PP version (fitting tightly)<br />

The drain bore behind the liquid end side (dampness can indicate<br />

a<br />

diaphragm rupture)<br />

Fault Possible cause<br />

No metering pump intake (during initial<br />

operation)<br />

No metering although drive is running (after<br />

longer period of operation)<br />

Metered liquid emerges from leakage<br />

opening of delivery unit<br />

Loss of metering capacity (after longer<br />

period of operation)<br />

Troubleshooting<br />

Suction head too high<br />

Backpressure in metering line (delivery<br />

side)<br />

Stroke setting 0 %<br />

Intake tank empty<br />

Issue: 10.06.2009 Instruction Manual <strong>DVZ</strong>-<strong>SKA</strong>-“BIOMASTER“ Page 26 of 37<br />

EOI<strong>SKA</strong>-SD2n<br />

Corrective measures<br />

Install pump closer to intake tank<br />

Eliminate backpressure (e.g. via bypass<br />

line)<br />

Increase stroke length (100 %)<br />

Top up medium and restart<br />

Gas cushion in intake line and liquid end Bleed intake line, check for leaks and<br />

restart<br />

Diaphragm defective Replace diaphragm<br />

Wearing parts in valves defective<br />

Deposits in valves<br />

DOSIERPUMPE / metering pump<br />

Replace wearing parts<br />

Clean or replace valve parts