9.9 WATER SPILLING OUT OF THE CONTACT TANK VENT<br />

This almost certainly is caused by failure of the Discharge pump, its controls, or by<br />

discharge valves being closed.<br />

1. Check valve positions, also in connecting pipe to overboard discharge.<br />

2. Make sure the pump switch is set to Auto and that power is present.<br />

3. Make sure the suction valve from the Disinfection Tank „V3“ is open<br />

4. Check out the starter, motor, (especially thermal protection switch) and pump.<br />

Controls should be set per "Set-Up for Operation" of this manual. Check function by<br />

manual start of pump, if this does not work, check level switch for proper function, if<br />

needed, clean out or replace.<br />

5. If the problem cannot be isolated and repaired quickly, bypass the sewage overboard<br />

to provide the crew with sanitary facilities.<br />

9.10 AERATION BLOWER CIRCUIT<br />

1. Press the reset button on the overload protection inside the control panel and turn the<br />

blower on to determine if the blower motor overloaded and dropped out of the circuit.<br />

2. Make sure that all the overload protection on the blower starter is the size specified on<br />

the electric scheme and set for current as indicated on the motor typeplate.<br />

3. If the blower motor will not start and the blower starter is energised, the problem is in<br />

the motor itself, the motor wiring, or the main contacts of the blower starter.<br />

4. If the blower motor will only operate when the blower button is manually held on, the<br />

blower starter auxiliary contacts are not closing in parallel with the blower button<br />

contacts. Replace auxiliary relay and start again.<br />

5. For mechanical malfunctions check the specific manufacturers documentation<br />

enclosed in this manual.<br />