TP001<br />

Thor Anders Aarhaug<br />

SINTEF<br />

Materials Technology<br />

Sem Sæl<strong>and</strong>svei 12<br />

TrondheimNO-7465 Norway<br />

taarhaug@ntnu.no<br />

Sintalyzer – A Fully Automated Analytical System <strong>for</strong> Fluoride Analysis<br />

146<br />

Co-Author(s)<br />

Kalman Nagy<br />

In the aluminum industry, fluorine analyses are interfered by the presence of aluminum, silicon <strong>and</strong> iron. Per<strong>for</strong>ming<br />

st<strong>and</strong>ard fluorine analyses using TISAB buffers will result in a negative analytical error due to complexation of<br />

fluoride. The Sintalyzer analytical system is a customized system <strong>for</strong> fluoride analysis in the aluminum industry. It<br />

is used exclusively in the Sc<strong>and</strong>inavian countries, <strong>and</strong> has also been installed in Germany, India, <strong>and</strong> Slovakia. The<br />

system uses several buffers that, in addition to proper sample preparation, render the fluoride electrochemically<br />

measurable. For optimal analytical per<strong>for</strong>mance, a st<strong>and</strong>ard addition technique is used. To avoid a dilution of the<br />

original matrix, micro volumes of highly concentrated st<strong>and</strong>ard is used. Since the concentration-voltage relation is<br />

given by the Nernst equation, the addition volumes have to be calculated dynamically in order to ensure an equal<br />

distance between the responses from the fluoride electrode. Although there are alternatives to potentiometry <strong>for</strong><br />

fluoride analysis in the aluminum industry, the investment cost of, <strong>for</strong> example an XRF, are 10 times higher <strong>and</strong><br />

requires by far more maintenance. Also, the sensitivity of the ion-selective electrode yields a better analytical<br />

per<strong>for</strong>mance. The Sintalyzer analytical system utilizes a st<strong>and</strong>ard addition technique that, by changing the ionselective<br />

electrode, can be extended to several other ions. By applying a lead ion-selective electrode, sulphur<br />

dioxide can be determined by titration with lead nitrate. The system comes with complete procedures <strong>for</strong> the<br />

analysis of fluoride of all matrices that are common in aluminum industry. The system is accredited according to<br />

Norwegian St<strong>and</strong>ard quality assurance of GLP.<br />

TP002<br />

Monica Adams<br />

Amersham Biosciences<br />

Development Integration/Genomics<br />

800 Centennial Avenue<br />

Piscataway, New Jersey 08854<br />

monica.adams@amersham.com<br />

The Aut<strong>omation</strong> of TempliPhi <strong>and</strong> GenomiPhi on the Tecan Genesis Freedom<br />

The Genesis Freedom Aut<strong>omation</strong> Workstation from Tecan offers you a simple, effective way to gain all the<br />

advantages of liquid h<strong>and</strong>ling <strong>and</strong> laboratory aut<strong>omation</strong>, which was used to automate Amersham Bioscience’s<br />

TempliPhi <strong>and</strong> GenomiPhi kits. The Tecan Gemini software system allows easy protocol set-up <strong>and</strong> operation<br />

of the Freedom workstation. Amersham Bioscience’s TempliPhi Amplification kit is a novel process to efficiently<br />

prepare DNA sequencing templates in 4 – 6 hours. Templates are prepared by rolling circle amplification using<br />

bacteriophage Phi29 DNA polymerase.The GenomiPhi kit utilizes Phi29 DNA polymerase enzyme to exponentially<br />

amplify single <strong>and</strong> double str<strong>and</strong>ed DNA by str<strong>and</strong> displacement amplification. The Tecan Freedom, with an eightchannel<br />

liquid h<strong>and</strong>ling arm, is capable of generating multiple TempliPhi or GenomiPhi 96-well reaction plates in<br />

more than half the time of manual pipetting. TempliPhi <strong>and</strong> GenomiPhi can be easily automated to work with liquid<br />

h<strong>and</strong>ling systems.