Photo 25<br />

Concrete beam with rein<strong>for</strong>cement showing appears<br />

to be butted up to the original brickwork.<br />

At the 1/F there was spalling to ceiling and beam to external wall. The beam adjacent the<br />

Main hall wall was very damp, The beam to the courtyard side was spalled with badly corroded<br />

steelwork. The beams and columns had splits consistent with corroded internal rein<strong>for</strong>cement.<br />

There was spalling to the s<strong>of</strong>fit <strong>of</strong> the slab next to external wall.<br />

Photo 26<br />

Spalling is not confined to the beams and columns<br />

but was also present in the slabs.<br />

The covering <strong>of</strong> the fl<strong>at</strong> ro<strong>of</strong> had de-bonded from the substr<strong>at</strong>e and was probably defective.<br />

Photo 27<br />

Areas <strong>of</strong> the fl<strong>at</strong> ro<strong>of</strong> covering had de-bonded and<br />

were probably defective.<br />