K9/1<br />

Chapter contents<br />

Pumps � Waste water lifting plants<br />

Waste water lifting plant<br />

for waste water free of<br />

faeces<br />

Waste water lifting plant<br />

for waste water containing<br />

faeces<br />

Information<br />

Basics . . . . . . . . . . . . . . . . . . . . . .594<br />

Installation . . . . . . . . . . . . . . . . . . .596<br />

■ Available as single or double lifting plant<br />

■ For the most diverse applications<br />

■ With a polyethylene or stainless steel collector tank<br />

■ With various pump types<br />

■ Upgradable with diverse accessories<br />

■ Available as single or double lifting plant<br />

■ For the most diverse applications<br />

■ With a polyethylene or stainless steel collector tank<br />

■ With various pump types<br />

■ Upgradable with diverse accessories<br />

Waste water lifting plants<br />

593<br />

<strong>14</strong>


<strong>14</strong><br />

Lifting plants<br />

Planning references<br />

Basics<br />

Image 1: Protection against backflow at drops to the sewer<br />

through a waste water lifting plant in multi-family buildings, retail<br />

properties and single family dwellings with in-law units .<br />

General information<br />

According to the building regulations of<br />

the states, structures may only be erected,<br />

if the waste water disposal is properly<br />

and permanently secured . Property areas,<br />

on which waste water accumulates, must<br />

be connected to the public sewer system,<br />

if it is operational . Only by this connection<br />

enforcement, meaning through the<br />

direct connection of the property drainage<br />

with the public sewage system, does<br />

the backflow problem also develop in<br />

this area . Depending on the sewer type,<br />

separate or combined sewage system, a<br />

variance in the frequency of the backflow<br />

can be anticipated . Grey and rain water<br />

is discharged in separate pipe systems<br />

in a separate sewage system . Backflow<br />

thereby occurs less frequently in grey<br />

water drains due to a prohibited discharge<br />

of waste material, pipe clogging as well as<br />

through operation based measures in the<br />

sewer system, however, basically cannot<br />

be excluded .<br />

The physical effect of a sewer backflow is<br />

based on the principle of the communicating<br />

pipes . Since the pipe systems of the<br />

property drainage are directly connected<br />

with the public sewer, the waste water<br />

enters the area of the property drainage<br />

via these pipes in the event of a backflow .<br />

The same water level develops here as<br />

in the public sewer . This means that the<br />

waste water leaks from all unsecured<br />

594<br />

openings, such as floor drains, toilets,<br />

etc . until the water levels are balanced .<br />

This results in a certain height for the<br />

backflow risk in property areas, for which<br />

special measures must be made against<br />

backflow within the property drainage .<br />

This height is called backflow level . The<br />

decisive backflow level is defined by the<br />

local authorities (local statutes) . If such<br />

a definition is missing, the height of the<br />

edge of the road above the connecting<br />

point of the property drainage pipe to the<br />

public sewage system applies as backflow<br />

level according to EN 12056-4 and<br />

DIN 1986-100 . Despite this, a backflow<br />

cannot be ruled out above this level, for<br />

example, due to a pipe obstruction .<br />

If a waste water backflow can penetrate<br />

into unprotected rooms within buildings,<br />

masonry and foundations are soaked .<br />

Water damages occur on furnishings .<br />

Health impairments via infectious diseases<br />

cannot be ruled out . Damages and the risk<br />

connected with a waste water backflow<br />

must therefore be kept as low as possible<br />

by a protection against backflow . The<br />

responsibility for this is generally that<br />

of the property owner according to the<br />

community waste water regulations . He<br />

can contract the proper experts, such as<br />

planners and installers for the planning<br />

and proper completion .<br />

Pumps � Waste water lifting plants<br />

Image 2: Protection against backflow, if the sewer is located<br />

higher than<br />

the sanitary drainage objects<br />

The maximum protection against backflow<br />

can be achieved by a waste water lifting<br />

plant by guiding its pressure line via the<br />

backflow level (image 1 and 2).<br />

The planning and dimensioning of waste<br />

water lifting plants is accomplished<br />

according to EN 12056-4 (valid from<br />

01 .01 .2001) and the residual standard<br />

DIN 1986-100 (introduced in March 2002) .<br />

Since EN 12056 with residual standard<br />

DIN 1986-100 covers all waste water<br />

systems in the area including the building's<br />

outer cover and DIN 1986-100also<br />

the area of the property up to the property<br />

boundary (EN 752 applies here from<br />

the building's outer cover to the sewer<br />

connection in Europe), when granting the<br />

contract, the standard according to which<br />

the waste water system must be planned<br />

and laid out must be defined .<br />

K9/1


K9/1<br />

Pumps � Waste water lifting plants<br />

Protection against backflow<br />

DIN 1986-100 'drainage systems for buildings<br />

and property" and EN 12056 "Gravity<br />

drainage systems inside buildings",<br />

stipulate that grey water that accumulates<br />

below the backflow level and rain water<br />

of surfaces below the backflow level must<br />

be returned to the public sewer system<br />

via an automatic lifting plant . The principle<br />

"accumulating surface water must be<br />

channelled away from the building and<br />

not penetrate the building" applies when<br />

Medium<br />

Waste water<br />

Any type of polluted waste water arising<br />

in the domestic and commercial sector<br />

is considered to be waste water . This<br />

includes rainwater, contaminated water<br />

through use, commercially used water,<br />

etc .<br />

Domestic sewage<br />

Domestic waste water is a mixture of<br />

drinking water, organic and inorganic<br />

substances in solid and dissolved form .<br />

The substances occurring in waste water<br />

from households according to experience<br />

is are mainly human faeces, hair, food<br />

waste, cleaning and washing agents,<br />

as well as various chemicals, paper,<br />

rags and sand (for example, in combined<br />

systems from rain water erosion .<br />

However, experience shows that all waste<br />

is initiated by ignorance or disregard,<br />

planning a drainage system . Accordingly,<br />

rain areas must be drained by separate<br />

pumping stations outside of the building .<br />

All drainage facilities located above the<br />

backflow level must be drained by natural<br />

drops (gravity principle); the waste water<br />

of these drainage facilities may not be<br />

drained via backflow stops and only via<br />

waste water lifting plants in exceptional<br />

cases (e .g . reconstruction) . If the respon-<br />

and must then be discharged by sanitary<br />

drainage objects . The pH value generally<br />

is between pH 6 .5 and pH 7 .5<br />

(pH 7 = neutral) .<br />

Grey water<br />

Waste water free of faeces .<br />

Black water<br />

Waste water containing faeces .<br />

Surface water<br />

Untapped rainwater, which is only contaminated<br />

by dirt on the drain surface by<br />

air pollution, contamination . The degree<br />

of contamination depends primarily on<br />

geography, urban proximity (air and land<br />

pollution) and frequency of rain . Impurities<br />

frequently contain oil, salt, or sand .<br />

Lifting plants<br />

Planning references<br />

sible authorities have not defined the<br />

backflow level, at least the height of the<br />

street to the connecting point applies as<br />

backflow level .<br />

Industrial waste water<br />

(= water for industrial use)<br />

Industrial waste water requires a detailed<br />

analysis of the medium, since the chemical<br />

constituents may vary greatly, becoming<br />

a threat to the installation . Corrosion<br />

damage can be observed here most<br />

frequently . Particular attention should<br />

be given to waste water from the textile<br />

and food industries . Impeller type (e .g .,<br />

blockage), shaft dimensions (due to highly<br />

different outflows) and a combination of<br />

materials (e .g . corrosion) of the installation<br />

are the key critical points here .<br />

595<br />

<strong>14</strong>


<strong>14</strong><br />

Lifting plants<br />

Planning references<br />

Installation<br />

Buoyancy safeguard<br />

A buoyancy safeguard is an attachment<br />

of a system/ pump at the bottom (or at<br />

the pump shaft in the ground), in order<br />

to prevent floating during flooding (or an<br />

increased groundwater level) of the area ,<br />

since damages may develop on connec-<br />

Ventilation<br />

Main ventilation<br />

Extension of a vertical sewage downpipe<br />

whose end is open towards the atmosphere<br />

above the last connecting line or<br />

the last connection .<br />

Secondary ventilation line<br />

Vertical vent pipe, which is connected<br />

to a waste water downpipe, to limit the<br />

pressure fluctuations within the waste<br />

Inlet<br />

The inlet pipe into the waste water lifting<br />

plant may not be reduced in the flow direction<br />

. A stop valve must be arranged on<br />

the inlet side (based on the replacement<br />

Pressure line<br />

Backflow level<br />

Highest point in an installation to which<br />

the contaminated water can rise . The<br />

backflow level is located in the area of<br />

greatest cross-sectional expansion . Installations<br />

should be designed so that the<br />

water from the drains cannot return to the<br />

pumping station . This could occur during<br />

storms, floods and heavy rainfall, if the<br />

municipal sewage system is not designed<br />

for such volumes . Damages that result<br />

hereby, are not covered by insurance<br />

Sound insulation<br />

Suitable measures (wall openings,<br />

low-noise valves, flow velocity) must be<br />

implemented in installations from the<br />

beginning, in order to minimize the noise<br />

Pressure line connection<br />

The connection of the pressure pipe is<br />

made on the base and collection line . Suitable<br />

pressure pipes, which can withstand<br />

the pressure of 1 .5 times of the maximum<br />

pump pressure of the system, must be<br />

used .<br />

596<br />

tions/pipes that could result in a leakage<br />

of the medium . The buoyancy safeguard<br />

is located directly on containers, or is<br />

subsequently installed or is already cast .<br />

Attention should be paid that the system/<br />

pump is located solid and stationary on<br />

water downpipe . Venting the lifting plants<br />

must be completed in accordance with EN<br />

12056-1 over the roof . The vent pipe may<br />

be introduced into both the main and the<br />

secondary ventilation .<br />

The ventilation of lifting plants may not be<br />

combined with the ventilation of a grease<br />

separator on the inflow side . A minimum<br />

cross-section of DN 70, or better DN<br />

100, must be provided for faeces lifting<br />

options of the system or for repair or<br />

maintenance work)<br />

and are only successfully enforceable in<br />

rare cases . A coverage is the choice of<br />

the operator / owner . Information on the<br />

height of the backflow level is defined in<br />

the local statutes .<br />

burden . This is also based on the fact that<br />

a subsequent modification is associated<br />

with high costs and designates a value<br />

The dimensioning of the basic line after<br />

being discharged into the discharge<br />

pipe is regulated in EN 12056-2 and EN<br />

12056-3 . In general, it appears that the<br />

basic line before reaching the pressure<br />

Pumps � Waste water lifting plants<br />

the underground and cannot begin to shift<br />

or turn .<br />

plants according to EN 12056-1 . Pressure<br />

relief valves are not permitted for<br />

lifting plants according to DIN 1986-100 .<br />

The drainage pipes must be connected to<br />

the lifting plant . The weight of the pipes<br />

or fittings must be handled accordingly<br />

on-site .<br />

Backflow loop<br />

A backflow loop represents an artificially<br />

elevated pipe run above the backflow<br />

level, so that backflow water can first<br />

distribute over all low lying open spaces .<br />

Since it can be assumed that a sufficient<br />

volume is available in the entire pipeline,<br />

the backflow loop presents the safest<br />

alternative against backflow.<br />

The liability is with the processor or<br />

planner when the backflow safety valve is<br />

missing .<br />

reduction of the entire area . DIN 4109 is<br />

a guideline for this .<br />

line must be selected one nominal diameter<br />

larger .<br />

Sanitary drainage objects may not be<br />

connected to the pressure line . It may<br />

also not be connected to grey water<br />

downpipes .<br />

K9/1


K9/1<br />

Pumps � Waste water lifting plants<br />

Installation premises<br />

A pump sump must be arranged for draining<br />

the set-up area . This can be drained<br />

by means of an automatic drainage pump<br />

in the pressure line of the lifting plant,<br />

behind the backflow loop .<br />

Container<br />

Collector tanks of faeces lifting plants<br />

must have an effective volume of 20 l<br />

, be waterproof and odour-sealed . They<br />

are considered as explosion endangered<br />

areas, as on-site shafts . The explosion<br />

protection regulations according to DIN<br />

Usable volume<br />

The volume between the power on and<br />

power off point of the pump is generally<br />

described as usable volume - also called<br />

required storage volume . In special cases,<br />

where the intake to the pumping station is<br />

located below the power on point of the<br />

pump and is therefore stored, the intake<br />

volume can be used to cover the required<br />

storage volume . It must be replaced<br />

at every pumping process, i .e . usable<br />

Electric installation<br />

The electrical installation must be performed<br />

by a professional . Switching and<br />

signalling devices must be installed in a<br />

Dimensioning<br />

The layout and dimensioning of the pumps<br />

is carried out in accordance with EN<br />

12056-4 . Here, the total delivery height<br />

and total inflow are determined .<br />

A pump must be selected for the values<br />

that reaches at least the delivery height<br />

and the delivery capacity determined in its<br />

operating point (taking into account the<br />

minimum flow velocity of 0 .7 m / s, max .<br />

2 .3 m / s) .<br />

In tank systems, it is important to guarantee<br />

that the useful tank volume (volume<br />

between the power on and off point) is<br />

greater than the volume in the pressure<br />

line<br />

The set-up area of the waste water lifting<br />

plant must be sufficiently ventilated to<br />

prevent condensation; it must also be<br />

sufficiently large so that a work area<br />

of at least 60 cm in width and height is<br />

/ EC Directive 94/9/EC ATEX must be<br />

observed .<br />

Collecting tanks of faecal lifting plants<br />

may not be structurally connected to the<br />

building .<br />

Surface water which accumulates outside<br />

volume > pressure line volume .<br />

Systems that prevent the penetration of<br />

materials and liquids into the waste water<br />

lifting plant, which extend hazardous or<br />

nuisance vapours or odours, which affect<br />

the materials in the waste water systems<br />

or interfere with the operation, must be<br />

arranged in beforehand . Such systems<br />

include: Oil and gasoline according to EN<br />

858 /DIN 1999-100, light liquids closures<br />

dry, accessible location . The signalling<br />

system must also be attached at an easily<br />

noticeable location .<br />

(above the backflow prevention up to the<br />

backflow loop) . This will ensure that the<br />

content of the pressure line is completely<br />

exchanged per pumping process to prevent<br />

anaerobic digestion processes .<br />

When calculating the useful volume, the<br />

following instructions should be followed:<br />

Pumps or lifting plants are usually designed<br />

for the S3 (intermittent operation),<br />

i .e . a sufficient downtime of the pump (to<br />

cool the motor) must be available after<br />

completing the pumping process after<br />

switching on the pump . This results in the<br />

following guidelines:<br />

Lifting plants<br />

Planning references<br />

available, next to and above all parts to<br />

be maintained . Adequate lighting must be<br />

available<br />

the building below the backflow level,<br />

must be delivered by a waste water lifting<br />

plant/pump separately from domestic<br />

waste water and outside the building .<br />

under DIN 4043, emulsion splitting plants,<br />

grease separators in accordance with EN<br />

1825/DIN 4040-100, starch separators<br />

according to factory standards, sand and<br />

sludge traps as well as neutralization<br />

plants .<br />

Motor<br />

capacity<br />

[kW]<br />

Air-cooled<br />

1500<br />

[rpm]<br />

Air-cooled<br />

2900<br />

[rpm]<br />

Up to 1 .5 80 40<br />

Up to 3 .0 45 23<br />

Up to 7 .5 30 15<br />

Up to 11 15 8<br />

More than<br />

11<br />

10 5<br />

Minimum run time for submerged<br />

pumps<br />

Motor<br />

capacity<br />

[kW]<br />

Submerged pump,<br />

half submerged minimum<br />

run time in sec<br />

Up to 4 120<br />

Up to 7 .5 <strong>14</strong>5<br />

From 7 .5 180<br />

597<br />

<strong>14</strong>


<strong>14</strong><br />

Lifting plants<br />

Planning references<br />

Types of impellers<br />

When selecting the impeller, verify which design is best for the particular use .<br />

Channel impeller<br />

The channel impeller is suitable for delivering<br />

grey water containing faeces, as well<br />

as delivering waste water with<br />

Free flow impeller<br />

A large open chamber in the pump housing<br />

(free ball passage) makes it possible<br />

that the liquid flows easily over the suction<br />

opening into the pump chamber and solid<br />

and long-fibre viscous products flowing,<br />

such as long bandages, fabrics, etc ., can<br />

easily pass through without clogging the<br />

pump housing .<br />

Cutting mechanism<br />

Particularly suitable for long fibres with<br />

solids of a greater magnitude that can be<br />

disintegrated .<br />

For reliable transport of delivered material<br />

through small pressure lines on even long<br />

distances .<br />

598<br />

solid and short fibrous solid and viscous<br />

products, sludge and organic materials .<br />

Another advantage: since no throttle gap<br />

is present between the impeller and the<br />

pump housing of free flow pumps, this<br />

design allows a great operational reliability<br />

in applications with very extensive<br />

downtimes . Corroding the impeller and<br />

therefore a blockage of the pump is<br />

thereby excluded .<br />

For the waste water disposal in even<br />

unfavourable terrain with large height<br />

differences .<br />

Pumps � Waste water lifting plants<br />

K9/1


K9/1<br />

Pumps � Waste water lifting plants<br />

Planning - procedure<br />

Clarification of preliminary conditions<br />

Installation premises<br />

■ in the building<br />

■ outdoors underground<br />

■ (Load class A, B or D)<br />

■ Backflow level<br />

■ Conveyance media<br />

■ Intake conditions into the sewer<br />

■ Conveyance height and pipe routing<br />

(distance to the sewer)<br />

Dimensioning of the plant<br />

■ Waste water inflow (connection data)<br />

■ Overall conveying height<br />

■ Calculation of the pump operating point<br />

■ Selection of the nominal pressure line<br />

width<br />

■ Selection of the required valves and<br />

fittings<br />

Selecting the plant<br />

■ Selection of the pump or lifting plant<br />

■ Selection of control systems and accessories<br />

■ Single or twin system<br />

■ Explosion protected model<br />

■ Definition of the pressure pipe,<br />

■<br />

vent pipe<br />

Current / voltage supply<br />

■ 230/400 V<br />

■ Power frequency 50 Hz<br />

■ Checking the minimum flow velocity<br />

■ Calculating the usable tank volume<br />

■ Shaft designation<br />

Standard<br />

■ EN 12050<br />

■ DIN 1986-100<br />

■ EN 12056<br />

■ EN 752<br />

■ EN 1610<br />

■ ATV-DVWK<br />

■ Local Policy<br />

Standard<br />

■ EN 12056-4<br />

■ EN 752<br />

■ ATV<br />

Lifting plants<br />

Planning references<br />

599<br />

<strong>14</strong>


K9/1<br />

Section contents<br />

Pumps � Waste water lifting plants � Waste water free of faeces<br />

Waste water lifting plant –<br />

under-ground installation<br />

Waste water lifting plant<br />

for free-standing installation<br />

Waste water lifting plant for waste water free of faeces<br />

Sinkamat series<br />

Sinkamat series<br />

Muli-Series<br />

Page<br />

Sinkamat-S 602<br />

Sinkamat-Z 604<br />

Sinkamat-K 606<br />

Accessories 608<br />

Sinkamat-K 610<br />

Accessories 612<br />

Muli-Mini mono 6<strong>14</strong><br />

Muli-Mini duo 616<br />

Accessories 618<br />

601<br />

<strong>14</strong><br />

Waste water lifting plants<br />

Waste water free of faeces


<strong>14</strong><br />

Waste water lifting plants<br />

Waste water free of faeces<br />

Waste water lifting plant – under-ground installation<br />

Sinkamat series<br />

Sinkamat-S<br />

Product information<br />

602<br />

<strong>ACO</strong> product advantages<br />

■ With high-quality stainless steel manhole<br />

cover<br />

■ With integrated acoustic signaller<br />

■ With separate sediment collection<br />

chamber for increased lifespan<br />

■ No ventilation line required<br />

■ Area of application<br />

For underground installation in frostprotected<br />

rooms below the backflow<br />

level, e .g . basement, hobby rooms<br />

and laundry rooms<br />

For domestic grey water free of faeces<br />

from showers, wash stands etc .<br />

■ Stainless steel cabinet, material grade<br />

304<br />

Ordering information<br />

460<br />

angled safety plug with<br />

manual / auto selection<br />

and signal installation<br />

(intermittent)<br />

alarm contact<br />

removable<br />

inlet - guiding plate<br />

156<br />

75<br />

inlet<br />

sediment collection<br />

chamber<br />

ca.496<br />

341<br />

inlet middle<br />

inlet left<br />

inlet right<br />

387 x 296<br />

180 136<br />

432<br />

ca.587<br />

separable cable<br />

coupling<br />

tube angle<br />

R 1 ¼<br />

pressure pipe R 1 ¼<br />

and DN 50 / SML<br />

ON<br />

OFF<br />

■ Stainless steel cover with hole pattern<br />

■ Lateral inlet openings, choice of DN 50,<br />

DN 70 or DN 100<br />

■ Connection ports DN 50 (plastic) for<br />

conduit<br />

■ Pressure pipe connection<br />

R 1¼“<br />

for threaded pipe<br />

DN 50 for SML pipe<br />

■ Grey water immersion pump with heavyduty<br />

AC motor<br />

■ Stainless steel motor housing and shaft<br />

■ Plastic pump housing and impeller<br />

■ With 5 m connecting cable and angled<br />

safety plug<br />

■ With magnetic float switch for low<br />

activation heights<br />

■ With integrated check valve R 1¼“<br />

ON/ alarm signal + autostart<br />

OFF<br />

127<br />

ca.70<br />

120<br />

<strong>14</strong>5<br />

260<br />

connection DN 50 /<br />

platic empty cable conduit<br />

and air ventilation<br />

case with<br />

connection rim<br />

inlet socket of stainless steel<br />

for SML attachment<br />

DN 50 DN 70 DN 100<br />

Pumps � Waste water lifting plants � Waste water free of faeces<br />

Construction with connection rim Construction without connection rim<br />

460<br />

angled safety plug with<br />

manual / auto selection<br />

and signal installation<br />

(intermittent)<br />

alarm contact<br />

removable<br />

Inlet - guiding plate<br />

156<br />

inlet<br />

sediment collection<br />

chamber<br />

ca.376<br />

341<br />

inlet middle<br />

inlet left<br />

inlet right<br />

387 x 296<br />

180 136<br />

432<br />

ca.480<br />

separable cablecoupling<br />

tube angle<br />

R 1 ¼<br />

pressure pipe R 1 ¼<br />

and DN 50 / SML<br />

ON/ alarm signal + autostart<br />

OFF<br />

ON<br />

OFF<br />

127<br />

ca.70<br />

120<br />

<strong>14</strong>5<br />

260<br />

connection DN 50 /<br />

plastic empty cable conduit<br />

and air ventilation<br />

case with<br />

connection rim<br />

K9/1


K9/1<br />

Pumps � Waste water lifting plants � Waste water free of faeces<br />

Type Description Motor rating Current<br />

consumption<br />

50/1-S<br />

50/2-S<br />

50/1-S<br />

50/2-S<br />

■ With connecting<br />

rim<br />

■ With connecting<br />

rim<br />

■ Without connecting<br />

rim<br />

■ Without connecting<br />

rim<br />

Performance parameters<br />

Remark: Maximum temperature of wastewater is only<br />

allowed for a short time .<br />

Waste water lifting plant – under-ground installation<br />

Sinkamat series<br />

Voltage Revolutions<br />

Grain<br />

size<br />

P1 P2<br />

[kW] [kW] [A] [V] [U/min] [mm] [kg]<br />

Weight Article No.<br />

0,43 0,21 2,1 230 2800 10 26 0159.03.47<br />

0,65 0,38 3,1 230 2800 10 26 0159.03.51<br />

0,43 0,21 2,1 230 2800 10 21 0159.03.45<br />

0,65 0,38 3,1 230 2800 10 21 0159.03.49<br />

[m] 12<br />

Gesamtförderhöhe H<br />

11<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

0<br />

0<br />

Leistungsdiagramm<br />

Mindestförderstrom DN 32<br />

2<br />

Mindestförderstrom DN 40<br />

4<br />

Mindestförderstrom DN 50<br />

6<br />

8<br />

Toleranzen ISO 2548/C<br />

n = 2800 U/min<br />

0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5<br />

10<br />

Förderstrom Q<br />

SINKAMAT 50/2 S<br />

SINKAMAT 50/1 S<br />

12<br />

<strong>14</strong><br />

16<br />

18<br />

20 [m³/h]<br />

Type Delivery<br />

Delivery flow Q with total delivery head H Conveyance media<br />

head<br />

temperature<br />

2 m 3 m 4 m 5 m 6 m 7 m 8 m Normal Maximum<br />

[m] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [°C] [°C]<br />

[l/s]<br />

5,5<br />

50/1-S 2 – 6 3,38 2,91 2,36 1,72 0,97 40 90<br />

50/2-S 2 – 8 4,44 4,02 3,61 3,11 2,5 1,94 1,19 40 90<br />

Infobox<br />

603<br />

<strong>14</strong><br />

Waste water lifting plants<br />

Waste water free of faeces


<strong>14</strong><br />

Waste water lifting plants<br />

Waste water free of faeces<br />

Waste water lifting plant – under-ground installation<br />

Sinkamat series<br />

Sinkamat-Z<br />

Product information<br />

604<br />

<strong>ACO</strong> product advantages<br />

■ With high-quality stainless steel manhole<br />

cover<br />

■ With separate sediment collection<br />

chamber for increased lifespan<br />

■ No ventilation line required<br />

■ Area of application<br />

For underground installation in frostprotected<br />

rooms below the backflow<br />

level, e .g . basement, hobby rooms<br />

and laundry rooms<br />

For domestic grey water free of faeces<br />

from showers, wash stands etc .<br />

■ Stainless steel cabinet, material grade<br />

304<br />

460<br />

Ordering information<br />

removable<br />

inlet - guiding plate<br />

inlet<br />

sediment collection<br />

chamber<br />

inlet middle<br />

inlet left<br />

inlet right<br />

pressure pipe R 1 ¼<br />

and DN 50 / SML<br />

ON<br />

OFF<br />

Remark: Other version (for example: double system) on<br />

request .<br />

■ Stainless steel cover with hole pattern<br />

■ Lateral inlet openings, choice of DN 50,<br />

DN 70 or DN 100<br />

■ Connection ports DN 50 (plastic) for<br />

conduit<br />

■ Pressure pipe connection<br />

R 1¼“<br />

for threaded pipe<br />

DN 50 for SML pipe<br />

■ Grey water immersion pump with heavyduty<br />

AC motor<br />

■ Stainless steel motor housing and shaft<br />

■ Plastic pump housing and impeller<br />

■ Pump housing seal for the motor via a<br />

mechanical seal<br />

■ With 10 m safety plug<br />

■ With ball float switch<br />

■ With integrated check valve R 1¼“<br />

connection DN 50 /<br />

plastic empty cable conduit<br />

and air ventilation<br />

Pumps � Waste water lifting plants � Waste water free of faeces<br />

Construction with connection rim Construction without connection rim<br />

156<br />

ca.496<br />

75<br />

341<br />

10 m cable<br />

387 x 296<br />

180 136<br />

432<br />

ca.587<br />

safety plug 230 V / 50 Hz<br />

127<br />

ca.<br />

100<br />

120<br />

170<br />

case with<br />

connection rim<br />

inlet socket of stainless steel<br />

for SML-attachment<br />

DN 50 DN 70 DN 100<br />

460<br />

removable<br />

inlet - guiding plate<br />

156<br />

ca.376<br />

341<br />

inlet<br />

sediment collection<br />

chamber<br />

inlet middle<br />

10 m cable<br />

inlet left<br />

inlet right<br />

387 x 296<br />

180 136<br />

432<br />

safety plug 230 V / 50 Hz<br />

ca.480<br />

Infobox<br />

pressure pipe R 1 ¼<br />

and DN 50 / SML<br />

ON<br />

OFF<br />

127<br />

ca.<br />

100<br />

170<br />

connection DN 50 /<br />

plastic empty cable conduit<br />

and air ventilation<br />

120<br />

case with<br />

connection rim<br />

K9/1


K9/1<br />

Pumps � Waste water lifting plants � Waste water free of faeces<br />

Type Description Motor rating Current<br />

consumption<br />

50/1-Z<br />

50/2-Z<br />

50/1-Z<br />

50/2-Z<br />

■ Without connecting<br />

rim<br />

■ Without connecting<br />

rim<br />

■ With connecting<br />

rim<br />

■ With connecting<br />

rim<br />

Performance parameters<br />

Type Delivery<br />

head<br />

Remark: Maximum temperature of wastewater is only<br />

allowed for a short time .<br />

Waste water lifting plant – under-ground installation<br />

Sinkamat series<br />

Voltage Revolutions<br />

Grain<br />

size<br />

P1 P2<br />

[kW] [kW] [A] [V] [U/min] [mm] [kg]<br />

Weight Article No.<br />

0,35 0,2 1,8 230 2800 10 26 0175.07.97<br />

0,65 0,35 3,5 230 2800 10 26 0175.08.45<br />

0,35 0,2 1,8 230 2800 10 21 0175.07.98<br />

0,65 0,35 3,5 230 2800 10 21 0175.08.46<br />

[m] 12<br />

Gesamtförderhöhe H<br />

11<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

0<br />

0<br />

Leistungsdiagramm<br />

Mindestförderstrom DN 32<br />

2<br />

Mindestförderstrom DN 40<br />

4<br />

Mindestförderstrom DN 50<br />

6<br />

SINKAMAT 50/1 Z<br />

8<br />

Toleranzen ISO 2548/C<br />

SINKAMAT 50/2 Z<br />

n = 2800 U/min<br />

0 0,5 1 1,5 2 2,5 3 3,5 4 4,5 5<br />

10<br />

Förderstrom Q<br />

12<br />

<strong>14</strong><br />

16<br />

18<br />

20 [m³/h]<br />

[l/s]<br />

5,5<br />

Delivery flow Q with total delivery head H Conveyance<br />

media temperature<br />

2 m 3 m 4 m 5 m 6 m 7 m 8 m 9 m 10 m Normal Maximum<br />

[m] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [°C] [°C]<br />

50/1-Z 2 – 6 2,22 1,94 1,66 1,32 0,92 40 90<br />

50/2-Z 2 – 10 4,82 4,58 4,28 3,97 3,58 3,15 2,64 2,05 1,41 40 90<br />

Infobox<br />

605<br />

<strong>14</strong><br />

Waste water lifting plants<br />

Waste water free of faeces


<strong>14</strong><br />

Waste water lifting plants<br />

Waste water free of faeces<br />

Waste water lifting plant – under-ground installation<br />

Sinkamat series<br />

Sinkamat-K<br />

Product information<br />

606<br />

<strong>ACO</strong> product advantages<br />

■ Quick coupler for fitting/removal of<br />

the pump without tools<br />

■ Optional waterproof concrete sealing<br />

possible<br />

■ Multiple connection possibilities<br />

■ Top section with frame dimensions<br />

198 x 198 mm or 360 x 300 mm<br />

(telescopic height adjustability)<br />

■ Optional manhole cover for selectable<br />

surface and odour seal<br />

■ Areas of application<br />

For underground installation in frostprotected<br />

rooms below the backflow<br />

level, e .g . basement, hobby rooms<br />

and laundry rooms<br />

For domestic grey water free of faeces<br />

from showers, wash stands etc .<br />

Ordering information<br />

PVC-U pressure pipe<br />

with integrated<br />

check valve<br />

WU-concrete<br />

sealing ring<br />

(optional)<br />

H min. 604<br />

PVC-U<br />

replacement pump<br />

50/1 Z m.<br />

10 m cable/Z.<br />

Sinkamat<br />

cable gland<br />

335<br />

Sinkamat-K (Article No. 620441)<br />

inlet<br />

DN 100<br />

Ø430<br />

Ø520<br />

670<br />

360<br />

Ø75<br />

30<br />

ventilation<br />

DN 50<br />

158 37 37<br />

270<br />

443<br />

565<br />

H max. 675<br />

inlet<br />

DN 100<br />

300<br />

■ Certified in accordance with<br />

EN 12050-2<br />

■ Polyethylene cabinet<br />

■ Useable volume: 15 l<br />

■ With 3 inlet sockets DN 100<br />

■ With height-adjustable top sections<br />

■ Stainless steel motor housing and shaft<br />

■ Plastic pump housing and impeller<br />

■ Pump housing seal for the motor via a<br />

mechanical seal<br />

■ With 10 m connecting cable and safety<br />

plug<br />

■ With ball float switch<br />

■ With integrated check valve R 1¼“<br />

■ Pressure pipe connection in accordance<br />

with EN ISO 15493<br />

PVC-U; 50-40-R 1¼“<br />

PVC-U pressure pipe<br />

with integrated<br />

check valve<br />

WU-concrete<br />

sealing ring<br />

(optional)<br />

PVC-U<br />

replacement<br />

pump 50/1 Z m.<br />

10 m cable/Z.<br />

Sinkamat<br />

Sinkamat-K (Article No. 620387)<br />

335 cable gland<br />

inlet<br />

DN 100<br />

Ø430<br />

Ø520<br />

670<br />

Ø75<br />

Pumps � Waste water lifting plants � Waste water free of faeces<br />

Inlet DN 50<br />

158 37 37<br />

270<br />

443<br />

541<br />

585<br />

inlet<br />

DN 100<br />

□198<br />

PVC-U pressure pipe<br />

with integrated<br />

check valve<br />

WU-concrete<br />

sealing ring<br />

(optional)<br />

H min. 604<br />

PVC-U<br />

replacement<br />

pump 50/1 Z m.<br />

10 m cable/Z.<br />

Sinkamat<br />

cable gland<br />

335<br />

Sinkamat-K (Article No. 620442)<br />

inlet<br />

DN 100<br />

Ø430<br />

Ø520<br />

670<br />

360<br />

Ø75<br />

30<br />

50<br />

ventilation<br />

DN 50<br />

158 37 37<br />

270<br />

443<br />

565<br />

H max. 675<br />

inlet<br />

DN 100<br />

150<br />

300<br />

K9/1


K9/1<br />

Pumps � Waste water lifting plants � Waste water free of faeces<br />

Type Top section Motor rating Current<br />

consumption<br />

50/1-K<br />

50/1-K<br />

50/1-K<br />

■ Frame dimensions:<br />

360 x 300 mm<br />

■ Reversible cover<br />

plate, load class K3<br />

■ Frame dimensions:<br />

198 x 198 mm<br />

■ Slotted grating, load<br />

class K3<br />

■ Frame dimensions:<br />

360 x 300 mm<br />

■ Manhole cover for<br />

selectable surface<br />

■ With odour seal<br />

■ With slotted grating<br />

Frame dimensions:<br />

150 x 150 mm<br />

Load class: K3<br />

Performance parameters<br />

[m]<br />

Gesamtförderhöhe H<br />

Remark: Maximum temperature of wastewater is only<br />

allowed for a short time .<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

Waste water lifting plant – under-ground installation<br />

Sinkamat series<br />

Voltage Revolutions<br />

Grain<br />

size<br />

P1 P2<br />

[kW] [kW] [A] [V] [U/min] [mm] [kg]<br />

Weight Article No.<br />

0,35 0,2 1,8 220 2800 10 23 620441<br />

0,35 0,2 1,8 220 2800 10 23 620387<br />

0,35 0,2 1,8 220 2800 10 23 620442<br />

Mindestförderstrom DN 32<br />

Mindestförderstrom DN 40<br />

Toleranzen ISO 2548 / C<br />

n = 2800 1 / min<br />

0<br />

0 0,5 1 1,5 2 2,5 3<br />

0 1 2 3 4 5 6 7 8 9 10<br />

Mindestförderstrom DN 50<br />

Förderstrom Q<br />

Type Delivery<br />

Delivery flow Q with total delivery head H Conveyance media<br />

head<br />

temperature<br />

2 m 3 m 4 m 5 m 6 m Normal Maximum<br />

[m] [l/s] [l/s] [l/s] [l/s] [l/s] [°C] [°C]<br />

50/1-K 2 – 6 2,22 1,94 1,66 1,32 0,92 40 90<br />

[l/s]<br />

[m³/h]<br />

Infobox<br />

607<br />

<strong>14</strong><br />

Waste water lifting plants<br />

Waste water free of faeces


<strong>14</strong><br />

Waste water lifting plants<br />

Waste water free of faeces<br />

Waste water lifting plant – under-ground installation<br />

Sinkamat series<br />

Accessories<br />

608<br />

432 x 341<br />

387 x 296<br />

427 x 336<br />

460 x 369<br />

387 x 296<br />

427 x 336<br />

587 x 496<br />

432 x 341<br />

387 x 296<br />

427 x 336<br />

587 x 496<br />

460 x 369<br />

387 x 296<br />

427 x 336<br />

116 (60 T)<br />

Hupe<br />

„AUS“<br />

Störung<br />

Summer<br />

Test<br />

116 (60 T)<br />

Hupe<br />

„AUS“<br />

Störung<br />

Summer<br />

DN50<br />

52<br />

DN70<br />

52<br />

Test<br />

200<br />

200<br />

75<br />

75<br />

200<br />

200<br />

116<br />

116<br />

Pumps � Waste water lifting plants � Waste water free of faeces<br />

Designation compatible with Description Article No.<br />

Top section ■ Sinkamat-S/Z<br />

Top section ■ Sinkamat-S/Z<br />

Top section ■ Sinkamat-S/Z<br />

Top section ■ Sinkamat-S/Z<br />

Cover ■ Sinkamat-S/Z<br />

Pickup ■ Sinkamat-S/Z<br />

Signal device (network<br />

dependent)<br />

Signal device (network<br />

independent)<br />

Inlet socket ■ Sinkamat-S/Z<br />

Inlet socket ■ Sinkamat-S/Z<br />

■ Automatic faeces backflow<br />

systems Quatrix-K Type 3F<br />

■ Sinkamat-S/-Z<br />

■ Muli polyethylene duo<br />

■ Muli polyethylene S mono/duo<br />

■ All Multi-Pro waste water lifting<br />

plants<br />

■ Suspension plant mono/duo<br />

■ Automatic faeces backflow<br />

systems Quatrix-K Type 3F<br />

■ Sinkamat-S/-Z<br />

■ Muli polyethylene S mono/duo<br />

■ All Multi-Pro waste water lifting<br />

plants<br />

■ Suspension plant mono/duo<br />

■ Stainless steel, material grade<br />

304<br />

■ Without connecting rim<br />

■ Height: 200 mm<br />

■ For larger installation depths<br />

■ Stainless steel, material grade<br />

304<br />

■ Without connecting rim<br />

■ Height: 200 mm<br />

■ For gas and odour-tight design<br />

■ Stainless steel, material grade<br />

304<br />

■ With connecting rim<br />

■ Height: 200 mm<br />

■ For larger installation depths<br />

■ Stainless steel, material grade<br />

304<br />

■ With connecting rim<br />

■ Height: 200 mm<br />

■ For gas and odour-tight design<br />

■ Stainless steel, material grade<br />

304<br />

■ With profile packing<br />

■ Sealed to gas and odour<br />

■ Screwed in place<br />

■ Fitted with container aeration<br />

■ With 10 m cable<br />

■ For a separate signal device/<br />

dry contact for fault signal level<br />

■ Visual and acoustic<br />

■ Network dependent<br />

■ Without pickup<br />

■ With dry contact for fault signal<br />

level<br />

■ With 1 m connecting cable and<br />

angled three-wire plug<br />

■ Visual and acoustic<br />

■ Self-charging<br />

■ Without pickup<br />

■ With dry contact for fault signal<br />

level<br />

■ With acoustic deletion<br />

■ With 1 m connecting cable and<br />

angled three-wire plug<br />

■ Stainless steel, material grade<br />

304<br />

■ DN 50<br />

■ Stainless steel, material grade<br />

304<br />

■ DN 70<br />

0159.03.42<br />

0175.20.73<br />

0159.03.43<br />

0159.03.44<br />

0159.38.82<br />

0159.12.46<br />

0159.12.30<br />

0159.12.31<br />

0159.03.37<br />

0159.03.36<br />

K9/1


K9/1<br />

Pumps � Waste water lifting plants � Waste water free of faeces<br />

289 30<br />

DN100<br />

52<br />

Ø676<br />

349<br />

Waste water lifting plant for free-standing installation<br />

Sinkamat series<br />

Designation compatible with Description Article No.<br />

Inlet socket ■ Sinkamat-S/Z<br />

Sealing flange<br />

■ Stainless steel, material grade<br />

304<br />

■ DN 100<br />

■ Backflow stops and Cleaning ■ For installation in waterproof<br />

pipes for installation in the base concrete<br />

plate<br />

Maximum groundwater level:<br />

■ Sinkamat-K (underground)<br />

3 m<br />

Cover plate complete ■ Sinkamat-K (underground)<br />

■ Manhole cover for selectable<br />

surface<br />

■ With slotted grating<br />

Frame dimensions:<br />

150 x 150 mm<br />

Load class: K 3<br />

■ With odour seal<br />

Water trap: 50 mm<br />

0159.03.35<br />

620382<br />

620385<br />

609<br />

<strong>14</strong><br />

Waste water lifting plants<br />

Waste water free of faeces


<strong>14</strong><br />

Waste water lifting plants<br />

Waste water free of faeces<br />

Waste water lifting plant for free-standing installation<br />

Sinkamat series<br />

610<br />

Pumps � Waste water lifting plants � Waste water free of faeces<br />

Sinkamat-K – polyethylene small lifting plant for above-ground installation<br />

Product information<br />

<strong>ACO</strong> product advantages<br />

■ Quick coupler for fitting/removal of<br />

the pump without tools<br />

■ Minimal installation dimensions via<br />

innovative design<br />

■ Maintenance without dismantling the<br />

inlet-side siphon<br />

■ Area of application:<br />

For above-ground installation in frostprotected<br />

rooms below the backflow<br />

level, e .g . basement, hobby rooms<br />

and laundry rooms<br />

For domestic grey water free of<br />

faeces from showers or wash stands<br />

etc .<br />

■ Certified in accordance with<br />

EN 12050-2<br />

Ordering information<br />

332<br />

■ Polyethylene container<br />

■ With multiple connection possibilities up<br />

to DN 50<br />

■ With forward-facing inspection opening<br />

■ Container aeration via activated carbon<br />

filter<br />

■ Grey water immersion pump with heavyduty<br />

AC motor<br />

■ Stainless steel motor housing and shaft<br />

■ Plastic pump housing and impeller<br />

■ Pump housing seal for the motor via a<br />

mechanical seal<br />

■ With 10 m connecting cable and safety<br />

plug<br />

■ With ball float switch<br />

■ With integrated check valve R 1¼“<br />

■ Pressure pipe connection in accordance<br />

with EN ISO 15493<br />

PVC-U, 50-40-R 1¼“<br />

329<br />

416<br />

pump 50/1-Z<br />

without grip for<br />

Sinkamat ÜF<br />

made of plastic<br />

PVC-U connection<br />

pressure pipe with<br />

integrated check valve<br />

K9/1


K9/1<br />

Pumps � Waste water lifting plants � Waste water free of faeces<br />

Type Motor rating<br />

Current consumption<br />

Remark: Maximum temperature of wastewater is only<br />

allowed for a short time .<br />

Waste water lifting plant for free-standing installation<br />

Muli-Series<br />

Voltage Revolutions Grain size Article No.<br />

P1 P2<br />

[kW] [kW] [A] [V] [U/min] [mm]<br />

50/1-Z 0,35 0,2 1,8 220 2800 10 620386<br />

Performance parameters<br />

[m]<br />

Gesamtförderhöhe H<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

Mindestförderstrom DN 32<br />

Mindestförderstrom DN 40<br />

Toleranzen ISO 2548 / C<br />

n = 2800 1 / min<br />

0<br />

0 0,5 1 1,5 2 2,5 3<br />

0 1 2 3 4 5 6 7 8 9 10<br />

Mindestförderstrom DN 50<br />

Förderstrom Q<br />

Type Delivery head Delivery flow Q with total delivery head H Conveyance media temperature<br />

2 m 4 m 6 m Normal Maximum<br />

[m] [l/s] [l/s] [l/s] [°C] [°C]<br />

50/1-Z 2 – 6 2,22 1,66 0,92 40 90<br />

[l/s]<br />

[m³/h]<br />

Infobox<br />

611<br />

<strong>14</strong><br />

Waste water lifting plants<br />

Waste water free of faeces


<strong>14</strong><br />

Waste water lifting plants<br />

Waste water free of faeces<br />

Waste water lifting plant for free-standing installation<br />

Muli-Series<br />

Accessories<br />

612<br />

Ø69<br />

Ø58<br />

Ø65<br />

Ø43<br />

66<br />

Pumps � Waste water lifting plants � Waste water free of faeces<br />

Designation compatible with Description Article No.<br />

Inlet socket DN 50<br />

Keyhole saw<br />

Adapter<br />

■ Cellar drain Junior with backflow<br />

stop<br />

■ Cellar drain DN 100<br />

■ Sinkamat-K (free-standing<br />

installation)<br />

■ Sinkamat-K (free-standing<br />

installation)<br />

■ Keyhole saw<br />

0150 .<strong>14</strong> .80<br />

■ Plastic<br />

■ For lateral inlet<br />

■ Customer-side fitting<br />

■ Weight: 0 .1 kg<br />

■ Bimetal hole saw suitable for<br />

Plastic<br />

Thin materials<br />

■ Intake with HSS drill for hole<br />

saw<br />

Diameter: 32 – 110 mm<br />

2410.00.04<br />

0150.<strong>14</strong>.80<br />

0150.<strong>14</strong>.81<br />

K9/1


K9/1<br />

Pumps � Waste water lifting plants � Waste water free of faeces<br />

Waste water lifting plant for free-standing installation<br />

Muli-Series<br />

613<br />

<strong>14</strong><br />

Waste water lifting plants<br />

Waste water free of faeces


<strong>14</strong><br />

Waste water lifting plants<br />

Waste water free of faeces<br />

Waste water lifting plant for free-standing installation<br />

Muli-Series<br />

Muli-Mini mono<br />

Product information<br />

6<strong>14</strong><br />

<strong>ACO</strong> product advantages<br />

■ Pneumatic level control with air bubble<br />

injection for increased operating<br />

security<br />

■ Minimal wear via a high useable<br />

volume<br />

■ Optimal access to the operating<br />

elements<br />

■ Quick and safe fitting of the pressure<br />

pipe via special mounting piece<br />

■ Areas of application<br />

Laundry rooms<br />

Warehouse<br />

Basements<br />

■ Polyethylene collector tank<br />

■ With drain plug<br />

■ With mounting set for buoyancy safety<br />

anchoring<br />

■ With 1 horizontal and 1 vertical inlet<br />

socket DN 100<br />

Ordering information<br />

450 (Z1)<br />

245<br />

180<br />

inlet<br />

DN100<br />

55<br />

drain plug<br />

flaps for<br />

buoyancy control<br />

inlet<br />

DN100<br />

pitot tube<br />

Ø640<br />

70<br />

<strong>ACO</strong><br />

■ With ventilation connection DN 70 for<br />

connection to the plastic pipe<br />

■ Pressure pipe connection<br />

1 ball check valve R 2“, with stainless<br />

steel pipe material grade 316<br />

1 ball valve R 2“ and special mounting<br />

piece DN 50 for elastic connection<br />

of the pressure pipe with an<br />

external diameter of 57 – 61 mm<br />

■ Grey water immersion pump<br />

With three-phase current immersion<br />

motor<br />

Protection category IP 68<br />

With lock ring/circular seal ring<br />

With blockage-free free flow impeller<br />

■ Switching and warning device<br />

Protection category IP 54<br />

With 1 .5 m cable and CEE plug<br />

With dry contact centralised fault<br />

signal and operating signal<br />

Inc . 4 m pneumatic control line between<br />

the lifting plant and control box<br />

Ø50<br />

min.250<br />

max.450<br />

625<br />

free flow pump<br />

grain size 38 mm<br />

ventilation DN70<br />

280<br />

ca. 1220<br />

70<br />

as option:<br />

additionally inlet socket DN50<br />

pneumatic control<br />

Pumps � Waste water lifting plants � Waste water free of faeces<br />

connection<br />

pneumatic<br />

control cable<br />

(4 m long)<br />

Ø57-61<br />

mini compressor<br />

for air bubble<br />

injection<br />

special fastening piece<br />

DN 50 (from Ø57 -Ø61 mm)<br />

ball valve R 2"<br />

ball retaining valve<br />

waste water collecting tank<br />

made of polyethylene<br />

switch box plug-in ready<br />

(250 x 195 x 100)<br />

connection<br />

centralised fault signal<br />

(4m long)<br />

cable<br />

1.5 m long with<br />

CEKON-connector 16 A<br />

electr. connection for<br />

mini compressor<br />

motor cable<br />

(4 m long)<br />

K9/1


K9/1<br />

Pumps � Waste water lifting plants � Waste water free of faeces<br />

Type Motor rating<br />

Muli-Mini V<br />

75-mono<br />

Muli-Mini V<br />

150-mono<br />

Current<br />

consumption<br />

Voltage Revolutions<br />

Remark: Maximum temperature of wastewater is only<br />

allowed for a short time .<br />

Waste water lifting plant for free-standing installation<br />

Muli-Series<br />

Grain<br />

size<br />

Total<br />

volume<br />

P1 P2 Inlet<br />

height<br />

Z1<br />

[kW] [kW] [A] [V] [U/<br />

min]<br />

Useable volume Weight Article No.<br />

Inlet<br />

from<br />

above<br />

[mm] [l] [l] [l] [kg]<br />

1,3 0,55 1,3 400 2900 35 150 75 90 65 0175.08.40<br />

2,5 1,1 2,5 400 2900 38 150 75 90 70 0175.08.41<br />

Performance parameters<br />

[m] 16<br />

Gesamtförderhöhe H<br />

<strong>14</strong><br />

12<br />

10<br />

8<br />

6<br />

4<br />

2<br />

0<br />

Mindestförderstrom DN 50<br />

Mindestförderstrom DN 65/70<br />

MULI-MINI-V 150<br />

MULI-MINI-V 75<br />

Toleranzen ISO 2548/C<br />

n = 2900 U/min<br />

1 2 3 4 5 6 7 8 9 10[l/s]<br />

[m³/h]<br />

3 6 9 12 15 18 21 24 27 30 33 36<br />

Förderstrom Q<br />

Type Delivery<br />

Delivery flow Q with total delivery head H Conveyance media<br />

head<br />

temperature<br />

2 m 4 m 6 m 8 m 10 m 12 m Normal Maximum<br />

[m] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [°C] [°C]<br />

Muli-Mini V<br />

75-mono<br />

Muli-Mini V<br />

150-mono<br />

2 – 7 6,2 4,0 2,0 40 60<br />

2 – 12 9,3 7,7 6,2 4,8 3,3 1,8 40 60<br />

Infobox<br />

615<br />

<strong>14</strong><br />

Waste water lifting plants<br />

Waste water free of faeces


<strong>14</strong><br />

Waste water lifting plants<br />

Waste water free of faeces<br />

Waste water lifting plant for free-standing installation<br />

Muli-Series<br />

Muli-Mini duo<br />

Product information<br />

616<br />

<strong>ACO</strong> product advantages<br />

■ Pneumatic level control with air bubble<br />

injection for increased operating<br />

security<br />

■ Minimal wear via a high useable<br />

volume<br />

■ Optimal access to the operating<br />

elements<br />

■ Fast and safe fitting via special mounting<br />

piece<br />

■ Areas of application<br />

Grease separator up to NS 4<br />

Laundry rooms<br />

Basements<br />

■ Polyethylene collector tank<br />

■ With drain plug<br />

■ With mounting set for buoyancy safety<br />

anchoring<br />

■ Each with 1 horizontal and 1 vertical<br />

inlet socket DN 100<br />

■ With ventilation connection DN 70 for<br />

connection to the plastic pipe<br />

Ordering information<br />

inlet<br />

DN100<br />

450 (Z1)<br />

245<br />

180<br />

55<br />

drain plug<br />

inlet<br />

DN100<br />

pitot tube<br />

■ Pressure pipe connection<br />

2 ball check valves R 2“<br />

Stainless steel Y-branch pipe, material<br />

grade 304<br />

1 ball valve R 2“ and special mounting<br />

piece DN 50 for elastic connection<br />

of the pressure pipe with an<br />

external diameter of 57 – 61 mm<br />

■ 2 grey water immersion pumps<br />

With three-phase current immersion<br />

motor - version D<br />

With AC immersion motor - version W<br />

Protection category IP 68<br />

With lock ring/circular seal ring<br />

With blockage-free free flow impeller<br />

■ Switching and warning device<br />

Protection category IP 54<br />

With 1 .5 m cable and CEE plug<br />

With dry contact centralised fault<br />

signal and operating signal<br />

Inc . 4 m pneumatic control line between<br />

the lifting plant and control box<br />

Ø640<br />

<strong>ACO</strong><br />

Ø50<br />

min.250<br />

max.450<br />

625<br />

free flow pump<br />

grain size 38 mm<br />

ventilation DN70<br />

280<br />

Pumps � Waste water lifting plants � Waste water free of faeces<br />

ca. 1360<br />

70<br />

Ø57-61<br />

special fastening piece<br />

DN 50 (from Ø57 -Ø61 mm)<br />

ball valve R 2"<br />

switch box plug-in ready<br />

(250 x 195 x 100)<br />

connection<br />

pneumatic<br />

control cable<br />

(4 m long)<br />

flaps for<br />

buoyancy control 70<br />

as option:<br />

additionally inlet socket DN50<br />

pneumatic control<br />

mini compressor<br />

for air bubble<br />

injection<br />

connection<br />

centralised fault signal<br />

(4m long)<br />

common pressure pipe R 2"<br />

ball retaining valve R 2"<br />

waste water collecting tank<br />

made of polyethylene<br />

cable<br />

1.5 m long with<br />

CEKON-connector 16 A<br />

electr. attachment for<br />

mini compressor<br />

motor cable<br />

(4m long)<br />

K9/1


K9/1<br />

Pumps � Waste water lifting plants � Waste water free of faeces<br />

Type Motor rating<br />

Muli-Mini V<br />

75-duo – D<br />

Muli-Mini V<br />

150-duo – D<br />

Muli-Mini V<br />

75-duo – W<br />

Muli-Mini V<br />

150-duo – W<br />

Current<br />

consumption<br />

Voltage Revolutions<br />

Remark: Maximum temperature of wastewater is only<br />

allowed for a short time .<br />

Waste water lifting plant for free-standing installation<br />

Muli-Series<br />

Grain<br />

size<br />

Total<br />

volume<br />

P1 P2 Inlet<br />

height<br />

Z1<br />

[kW] [kW] [A] [V] [U/<br />

min]<br />

Useable volume Weight Article No.<br />

Inlet<br />

from<br />

above<br />

[mm] [l] [l] [l] [kg]<br />

1,3 0,55 1,3 400 2900 35 150 75 90 88 0175.07.72<br />

2,5 1,1 2,5 400 2900 38 150 75 90 88 0175.08.33<br />

1,3 0,55 3,8 230 2900 35 150 75 90 88 0175.18.47<br />

2,5 1,1 8,2 230 2900 38 150 75 90 88 0175.24.84<br />

Performance parameters<br />

[m] 16<br />

Gesamtförderhöhe H<br />

<strong>14</strong><br />

12<br />

10<br />

8<br />

6<br />

4<br />

2<br />

0<br />

Mindestförderstrom DN 50<br />

Mindestförderstrom DN 65/70<br />

MULI-MINI-V 150<br />

MULI-MINI-V 75<br />

Toleranzen ISO 2548/C<br />

n = 2900 U/min<br />

1 2 3 4 5 6 7 8 9 10[l/s]<br />

[m³/h]<br />

3 6 9 12 15 18 21 24 27 30 33 36<br />

Förderstrom Q<br />

Type Delivery<br />

Delivery flow Q with total delivery head H Conveyance media<br />

head<br />

temperature<br />

2 m 4 m 6 m 8 m 10 m 12 m Normal Maximum<br />

[m] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [°C] [°C]<br />

Muli-Mini V<br />

75-duo – D<br />

Muli-Mini V<br />

150-duo – D<br />

Muli-Mini V<br />

75-duo – W<br />

Muli-Mini V<br />

150-duo – W<br />

2 – 7 6,2 4,0 2,0 40 60<br />

2 – 12 9,3 7,7 6,2 4,8 3,3 1,8 40 60<br />

2 – 7 6,2 4,0 2,0 40 60<br />

2 – 12 9,3 7,7 6,2 4,8 3,3 1,8 40 60<br />

Infobox<br />

617<br />

<strong>14</strong><br />

Waste water lifting plants<br />

Waste water free of faeces


<strong>14</strong><br />

Waste water lifting plants<br />

Waste water free of faeces<br />

Waste water lifting plant for free-standing installation<br />

Muli-Series<br />

Accessories<br />

Ø50<br />

10<br />

15<br />

Ø120<br />

Ø110<br />

618<br />

70<br />

91<br />

<strong>14</strong>0<br />

176<br />

Ø62<br />

Ø133<br />

80<br />

Pumps � Waste water lifting plants � Waste water free of faeces<br />

Designation compatible with Description Article No.<br />

Inlet valve DN 50<br />

Inlet valve DN 100<br />

■ Eco-Mobil<br />

■ Muli-Mini<br />

■ Waste water lifting plants<br />

■ Polyethylene grease separator<br />

■ Polyethylene starch separator<br />

Connection port ■ Muli-Mini mono/duo<br />

Special mounting<br />

piece<br />

■ Muli-Mini<br />

■ PVC<br />

■ DN 50<br />

■ With sealing ring in accordance<br />

with DIN 19538<br />

■ PVC<br />

■ Construction length: 176 mm<br />

■ Weight: 2 .75 kg<br />

■ DN 50<br />

■ Bushing type A<br />

40 x 50 x R 1¾“<br />

■ Minimum installation height:<br />

250 mm<br />

■ As additional components for<br />

the pressure pipe DN 80<br />

0175.18.33<br />

0175.13.84<br />

0175.09.27<br />

0175.07.79<br />

K9/1


K9/1<br />

Pumps � Waste water lifting plants � Waste water free of faeces<br />

Waste water lifting plant for free-standing installation<br />

Muli-Series<br />

619<br />

<strong>14</strong><br />

Waste water lifting plants<br />

Waste water free of faeces


Hinweis: @@ Dies ist eine Infobox-VORLAGE<br />

Zubehör AAAAA ➔ Seite xxx .<br />

Zubehör BBBBB ➔ Seite xxx .<br />

Infobox


K9/1<br />

Section contents<br />

Waste water lifting plant<br />

for pre-wall installation<br />

Waste water lifting plant<br />

for free-standing installation<br />

Waste water lifting plant for waste water containing faeces<br />

Pumps � Waste water lifting plants � Waste water containing faeces<br />

Fäkablock<br />

Muli-Series<br />

621<br />

Page<br />

Fäkablock II 622<br />

Accessories 625<br />

Muli-Star 626<br />

Muli-PE duo 628<br />

Muli-PE-S mono 630<br />

Muli-PE-S duo 632<br />

Muli Pro-PE K duo 634<br />

Muli Pro-PE V duo 636<br />

Muli Pro-PE K parallel 638<br />

Muli Pro-PE V parallel 640<br />

Muli Pro 1 .x VA duo 642<br />

Muli Pro 2 .x VA duo 644<br />

Accessories 646<br />

<strong>14</strong><br />

Waste water lifting plants<br />

Waste water containing faeces


<strong>14</strong><br />

Waste water lifting plants<br />

Waste water containing faeces<br />

Waste water lifting plant for pre-wall installation<br />

Fäkablock<br />

Fäkablock II<br />

Product information<br />

622<br />

<strong>ACO</strong> product advantages<br />

■ Easy maintenance due to easily accessible<br />

function elements<br />

■ Connection of up to 3 toilets<br />

■ High-grade waste water lifting plants in<br />

accordance with EN 12050-1<br />

■ Areas of application<br />

For the drainage of toilet facilities<br />

■ Wall mounted or pre-wall installation<br />

■ Channel impeller centrifugal pump in<br />

block assembly<br />

■ Steel panel collector tank<br />

Interior corrosion protection<br />

Coated exterior<br />

■ Switchgear<br />

Protection category IP 54, enclosed<br />

with insulating material<br />

With 1 strip terminal<br />

With 1 motor contactor<br />

With 1 motor overload switch<br />

Signal lamp „malfunction“<br />

Pneumatic level switching<br />

Signal device, visual and acoustic<br />

Network dependent<br />

With dry contact for fault signal „level<br />

high“<br />

■ WC wall connection<br />

2 opposite facing push-fit sockets for<br />

WC connectors, diameter: 90 mm<br />

Inlet height bottom edge of FÄKA-<br />

BLOCK II up to the middle of the WC<br />

drain: 340 mm<br />

Additional WC connection on the<br />

container-side with inlet sockets<br />

DN 100 (accessories)<br />

■ Shower connection<br />

On the container side with eccentric<br />

inlet socket: DN 50, DN 70 or<br />

DN 100 (accessories)<br />

■ Washbasin connection<br />

Container side DN 50, DN 70 or<br />

DN 100 (accessories) or on the motor<br />

compartment side DN 40 KA<br />

■ Pressure pipe connection<br />

Backflow valve with special mounting<br />

element for elastic connection of the<br />

pressure pipe: DN 100<br />

With drain spigot R ½“ for emptying<br />

the pressure pipe<br />

■ Connection ventilation line<br />

Pipe sockets for connection with CV<br />

connecting collar: DN 70/SML or KA<br />

pipe<br />

■ Aluminium screen for motor compartment<br />

Anodized matt surface<br />

With aeration slots<br />

Pumps � Waste water lifting plants � Waste water containing faeces<br />

K9/1


K9/1<br />

Pumps � Waste water lifting plants � Waste water containing faeces<br />

Ordering information<br />

pressure pipe DN 100 SML<br />

or DN 80 on request<br />

(optional)<br />

inlet<br />

washbasin<br />

backflow valve DN 80<br />

with integrated special<br />

fastening piece<br />

800<br />

580<br />

263<br />

10<br />

switch box<br />

including<br />

level switch<br />

Ø50<br />

Ø75<br />

Ø<strong>14</strong>0<br />

emptying R 1/2<br />

904<br />

ca. 964<br />

ca. 1004<br />

Type Motor rating Current<br />

consumption<br />

flushing cistern for building in<br />

GEBERIT-KOMBIFIX – on site<br />

double-sided possible<br />

ventilation DN 70 SML<br />

DN 40/KA<br />

OFF<br />

mounting supports for<br />

toilet with flushing valve<br />

ON<br />

Warn<br />

FFB<br />

Waste water lifting plant for pre-wall installation<br />

Fäkablock<br />

180<br />

120 130 88 75<br />

220<br />

plug-in sleeve DN 80 (Ø90)<br />

for toilet<br />

- double-sided-<br />

Voltage Revolutions<br />

connection for<br />

washbasin<br />

DN 40 / KA<br />

inlet is blind<br />

locked !<br />

optional<br />

inlet connection<br />

DN 50 / 70 / 100 SML<br />

- accessory-<br />

Grain<br />

size<br />

120<br />

Total<br />

volume<br />

605 x 365 x 3<br />

The maintenance opening in the engine compartment<br />

can be mounted left and / or right to the container<br />

1x front cover made of aluminum with frame-like spacer<br />

(visible side) 2 x 390 x 630<br />

1x cover plate made of steel<br />

(hidden side) 3 x 365 x 605<br />

91<br />

390<br />

Useable<br />

volume<br />

P1 P2 Inlet<br />

height<br />

Z1<br />

[kW] [kW] [A] [V] [U/min] [mm] [l] [l] [kg]<br />

20<br />

630 x 390 x 2<br />

ca. 1210<br />

display<br />

shows detail with<br />

cover plate made of<br />

aluminium<br />

Weight Article No.<br />

Fäkablock-II 1 0,75 2,15 400 <strong>14</strong>50 55 40 22 132 0175.00.90<br />

623<br />

<strong>14</strong><br />

Waste water lifting plants<br />

Waste water containing faeces


<strong>14</strong><br />

Waste water lifting plants<br />

Waste water containing faeces<br />

Waste water lifting plant for pre-wall installation<br />

Fäkablock<br />

Performance parameters<br />

624<br />

[m]<br />

Gesamtförderhöhe H<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

0<br />

0<br />

0<br />

1<br />

6<br />

2<br />

3<br />

Mindestförderstrom DN80<br />

12<br />

4<br />

18<br />

5<br />

Förderstrom Q<br />

Mindestförderstrom DN100<br />

6<br />

Pumps � Waste water lifting plants � Waste water containing faeces<br />

Toleranzen ISO 2548/C<br />

24<br />

7<br />

n = <strong>14</strong>50 U/min<br />

8<br />

30<br />

9<br />

36 [m³/h]<br />

[l/s]<br />

10<br />

Type Delivery head Delivery flow Q with<br />

total delivery head H<br />

Conveyance media temperature<br />

1 m Normal Maximum<br />

[m] [l/s] [°C] [°C]<br />

Fäkablock-II 1 – 3,5 9,2 45 80<br />

K9/1


K9/1<br />

Pumps � Waste water lifting plants � Waste water containing faeces<br />

Accessories<br />

175<br />

25<br />

135 60<br />

15<br />

60<br />

60<br />

Ø80<br />

Ø110<br />

Ø60<br />

Waste water lifting plant for pre-wall installation<br />

Fäkablock<br />

Designation compatible with Description Article No.<br />

Hand switch ■ Fäkablock II<br />

Inlet socket ■ Fäkablock II<br />

Inlet socket ■ Fäkablock II<br />

Inlet socket ■ Fäkablock II<br />

O-ring<br />

■ Fäkablock II<br />

■ Muli series<br />

■ 3 pole<br />

■ With padlock stop<br />

■ DN 50/SML<br />

■ Eccentric<br />

■ In accordance with DIN 19522<br />

■ DN 70/SML<br />

■ Eccentric<br />

■ In accordance with DIN 19522<br />

■ DN 100/SML<br />

■ Eccentric<br />

■ In accordance with DIN 19522<br />

■ As additional components for<br />

the pressure pipe DN 80<br />

0159.12.37<br />

0159.04.33<br />

0159.04.34<br />

0159.30.05<br />

0159.37.97<br />

625<br />

<strong>14</strong><br />

Waste water lifting plants<br />

Waste water containing faeces


<strong>14</strong><br />

Waste water lifting plants<br />

Waste water containing faeces<br />

Waste water lifting plant for free-standing installation<br />

Muli-Series<br />

Muli-Star<br />

Product information<br />

626<br />

<strong>ACO</strong> product advantages<br />

■ Marginal weight 31 kg<br />

■ Smoothness via low revolutions<br />

■ Free passage: 57 mm<br />

■ Quick fitting<br />

■ Ready for connection<br />

■ Installation via manhole cover KM 600<br />

possible<br />

■ Blockage-free free flow impeller<br />

■ Area of application<br />

Detached houses<br />

Basement flats<br />

■ Polyethylene collector tank<br />

■ With scour plug<br />

■ With revision opening for easy maintenance,<br />

diameter: 133 mm<br />

■ With mounting set for buoyancy safety<br />

anchoring<br />

■ Connection for the manual membrane<br />

pump R 1½“<br />

■ With 3 horizontal inlet sockets DN 100<br />

■ With 1 vertical inlet socket DN 50/<br />

DN 100<br />

■ With ventilation connection DN 50 for<br />

connection to the plastic pipe<br />

Ordering information<br />

ventilation DN 50<br />

700<br />

470<br />

400<br />

collecting tank<br />

attachment for<br />

buoyancy safeguard<br />

access screw<br />

cap DN 125<br />

cap / passage<br />

float switch<br />

free flow<br />

centrifugal pump<br />

Ø52<br />

Ø108 - 1<strong>14</strong>,3<br />

135<br />

520<br />

■ Pressure pipe connection<br />

Special backflow valve with integrated<br />

ball in cabinet and with emptying<br />

screw<br />

With integrated special mounting element<br />

DN 100 for elastic connection<br />

of the pressure pipe with an outside<br />

diameter of 108 – 1<strong>14</strong> .3 mm<br />

With connecting flange for stop valve<br />

DN 80 PN 10<br />

■ Pump unit<br />

3-phase motor (MDS1): 400 V, 50 Hz<br />

AC motor (MWS1): 230 V, 50 Hz<br />

Protection category IP 68<br />

With blockage-free free flow impeller<br />

■ With float switch, settable to inlet height<br />

■ Switching and warning device<br />

Protection category IP 54<br />

With 1 .5 m cable and CEE plug (with<br />

MDS1) or with safety plug (MWS1)<br />

With dry contact centralised fault<br />

signal and operating signal<br />

Inc . 5 m pneumatic control line between<br />

the lifting plant and control box<br />

■ LGA test certificate: No . 7391278-01<br />

500<br />

175<br />

integrated special<br />

backflow valve<br />

with lifting device<br />

Ø110<br />

100<br />

special fixing part<br />

for elastic connection to<br />

the pressure pipeline DN 80/100<br />

(option: seal ring DN 80)<br />

127<br />

inlet DN 100<br />

250<br />

510<br />

575<br />

inlet DN 50<br />

Ø110<br />

180<br />

40<br />

connection Ø 48 for<br />

membrane pump<br />

Pumps � Waste water lifting plants � Waste water containing faeces<br />

Ø52<br />

230<br />

Ø110<br />

45<br />

outlet R 1<br />

250 (T100) cable (1.5 m long)<br />

with CEE-connector (MDS) or<br />

isolated ground connector (MWS)<br />

switch box<br />

(plug in)<br />

K9/1


K9/1<br />

Pumps � Waste water lifting plants � Waste water containing faeces<br />

Type Motor rating<br />

Muli-Star<br />

MDS1<br />

Muli-Star<br />

MWS1<br />

P1 P2 Currentconsumption<br />

Characteristics Grain<br />

size<br />

Voltage<br />

Frequency<br />

Revolutions<br />

[kW] [kW] [A] [V] [Hz] [U/<br />

min]<br />

Remark: Maximum temperature of wastewater is only<br />

allowed for a short time .<br />

Waste water lifting plant for free-standing installation<br />

Muli-Series<br />

Total<br />

volume<br />

Useable volume Weight Article No.<br />

Inlet<br />

height<br />

Z1<br />

Inlet<br />

height<br />

Z2<br />

Inlet<br />

from<br />

above<br />

[mm] [l] [l] [l] [l] [kg]<br />

1 0,75 1,93 400 50 1380 55 60 20 25 30 31 1200.00.00<br />

1,1 0,75 5,05 230 50 <strong>14</strong>10 55 60 20 25 30 31 1200.00.01<br />

Performance parameters<br />

[m] 8<br />

Gesamtförderhöhe H<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

0<br />

Leistungsdiagramm Toleranzen ISO 2548/C<br />

Mindestförderstrom DN 80<br />

Mindestförderstrom DN 100<br />

n = <strong>14</strong>00 U/min<br />

0 1 2 3 4 5 6 7 8 9 10 11 12<br />

0 5 10 15 20 25 30 35 40 45<br />

Förderstrom Q<br />

MDS (Drehstrom)<br />

MWS (Wechselstrom)<br />

Type Delivery<br />

head<br />

Delivery flow Q with total delivery head H Conveyance media temperature<br />

2 m 4 m 6 m Normal Maximum<br />

[m] [l/s] [l/s] [l/s] [°C] [°C]<br />

Muli-Star<br />

MDS1<br />

Muli-Star<br />

MWS1<br />

2 – 6,4 10,9 8,6 4,5 40 60<br />

2 – 6,4 9,7 4,4 40 60<br />

[l/s]<br />

[m³/h]<br />

Infobox<br />

627<br />

<strong>14</strong><br />

Waste water lifting plants<br />

Waste water containing faeces


<strong>14</strong><br />

Waste water lifting plants<br />

Waste water containing faeces<br />

Waste water lifting plant for free-standing installation<br />

Muli-Series<br />

Muli-PE duo<br />

Product information<br />

628<br />

<strong>ACO</strong> product advantages<br />

■ Quick fitting<br />

■ Ready for connection<br />

■ High useable volume - up to 100 l<br />

■ Areas of application<br />

Behind grease separator up to NS 7 -<br />

in conjunction with air bubble injection<br />

Apartment housing<br />

Office buildings<br />

■ Polyethylene collector tank<br />

■ With drain plug<br />

■ With connection for the manual membrane<br />

pump R 1½“<br />

■ With mounting set for buoyancy safety<br />

anchoring<br />

■ With 2 horizontal inlet sockets DN 100/<br />

DN 150<br />

■ With 1 horizontal inlet socket with<br />

gradation DN 100/DN 150<br />

■ With ventilation socket DN 100 for<br />

connection to the plastic pipe<br />

Ordering information<br />

3<br />

160<br />

ca. 950<br />

200 260<br />

55<br />

3<br />

270<br />

drain plug<br />

750<br />

pressure pipe<br />

single chanel impeller<br />

centrifugal pump<br />

DN100<br />

Ø108-1<strong>14</strong><br />

165<br />

■ Pressure pipe connection<br />

With 2 special backflow valves DN 80<br />

With drain spigot R ½“<br />

Inc . Y-branch pipe with cleaning opening<br />

and special mounting element<br />

DN 80/DN 100 for elastic connection<br />

of the pressure pipe with an outside<br />

diameter of: 108 – 1<strong>14</strong> .3 mm<br />

■ 2 pump units<br />

Motor 400 V, 50 Hz<br />

Protection category IP 68<br />

With channel impeller<br />

■ Pneumatic level switching with pilot tube<br />

and pneumatic control line<br />

■ Switching and warning device<br />

Protection category IP 54<br />

With 1 .5 m cable and CEE plug<br />

With dry contact centralised fault<br />

signal and operating signal<br />

Inc . 4 m pneumatic control line between<br />

the lifting plant and control box<br />

70<br />

flaps for<br />

buoyancy control<br />

810<br />

890<br />

975<br />

connection<br />

pneumatic control<br />

cable (4m long)<br />

connection<br />

centralised<br />

fault signal<br />

motor cable<br />

(4m long )<br />

160<br />

110<br />

105<br />

210<br />

165<br />

100 124<br />

70<br />

650<br />

485<br />

tube sockets Ø48 mm<br />

for connection to<br />

manual membrane pump R 1 ½“<br />

pneumatic control<br />

switch box plug-in ready<br />

(250 x 195 x 100)<br />

connection<br />

mini compressor<br />

58<br />

400 (Z2)<br />

250 (Z1)<br />

ventilation DN100<br />

Pumps � Waste water lifting plants � Waste water containing faeces<br />

cable 1.5 m long<br />

with CEKON-plug 16 A<br />

70 70<br />

waste water collecting tank made of polyethylene<br />

124<br />

55<br />

special fastening piece<br />

DN 80/100<br />

Y-branch pipe DN 80<br />

backflow valve DN 80<br />

upper inlet socket with<br />

selectable nominal diameter<br />

DN 100/150<br />

pitot tube<br />

lateral inlet socket with<br />

selectable nominal diameter<br />

DN100/150<br />

K9/1


K9/1<br />

Pumps � Waste water lifting plants � Waste water containing faeces<br />

Type Motor rating<br />

P1 P2 Currentconsumption<br />

Characteristics Grain<br />

size<br />

Voltage<br />

Frequency<br />

Revolutions<br />

[kW] [kW] [A] [V] [Hz] [U/<br />

min]<br />

Remark: Maximum temperature of wastewater is only<br />

allowed for a short time .<br />

Waste water lifting plant for free-standing installation<br />

Muli-Series<br />

Total<br />

volume<br />

Useable volume Weight Article No.<br />

Inlet<br />

height<br />

Z1<br />

Inlet<br />

height<br />

Z2<br />

Inlet<br />

from<br />

above<br />

[mm] [l] [l] [l] [l] [kg]<br />

Muli-PE duo 1 0,75 2,15 400 50 1500 55 <strong>14</strong>5 80 100 100 180 0159.04.17<br />

Muli-PE/1<br />

duo<br />

Muli-PE/2<br />

duo<br />

Muli-PE/3<br />

duo<br />

2,01 1,5 3,6 400 50 3000 55 <strong>14</strong>5 80 100 100 180 0159.04.19<br />

2,94 2,2 5,2 400 50 3000 55 <strong>14</strong>5 80 100 100 185 0159.04.21<br />

3,87 3 7,1 400 50 3000 55 <strong>14</strong>5 80 100 100 190 0159.04.23<br />

Performance parameters<br />

Type Delivery<br />

head<br />

Leistungsdiagramm<br />

[m] 24<br />

Gesamtförderhöhe H<br />

22<br />

20<br />

18<br />

16<br />

<strong>14</strong><br />

12<br />

10<br />

8<br />

6<br />

4<br />

2<br />

0<br />

0<br />

0<br />

Mindestförderstrom DN 80<br />

Mindestförderstrom DN 100<br />

MULI-PE / 1<br />

MULI-PE<br />

Toleranzen ISO 2548/C<br />

MULI-PE / 2<br />

MULI-PE / 3<br />

6 12 18 24 30 3642<br />

48 54 60 66 72 78 [m³/h]<br />

[l/s]<br />

2,5 5 7,5 10 12,5 15 17,5 20<br />

Förderstrom Q<br />

Delivery flow Q with total delivery head H Conveyance<br />

media temperature<br />

2 m 4 m 6 m 8 m 10 m 12 m <strong>14</strong> m 16 m 18 m Normal<br />

Infobox<br />

Maximum<br />

[m] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [°C] [°C]<br />

Muli-PE duo 2 – 6 12,7 10,0 5,8 40 60<br />

Muli-PE/1<br />

duo<br />

Muli-PE/2<br />

duo<br />

Muli-PE/3<br />

duo<br />

8 – 12 11,5 8,66 5,67 40 60<br />

8 – 16 15,6 12,7 9,97 7,08 4,25 40 60<br />

8 – 18 19,1 16,4 13,6 10,6 7,58 4,66 40 60<br />

629<br />

<strong>14</strong><br />

Waste water lifting plants<br />

Waste water containing faeces


<strong>14</strong><br />

Waste water lifting plants<br />

Waste water containing faeces<br />

Waste water lifting plant for free-standing installation<br />

Muli-Series<br />

Muli-PE-S mono<br />

Product information<br />

630<br />

<strong>ACO</strong> product advantages<br />

■ High-grade waste water lifting plant<br />

with submerged motor pump and<br />

cutting mechanism<br />

■ Various inlet heights<br />

■ Low costs via small pressure pipe<br />

profile<br />

■ Areas of application<br />

Renovation of an old building<br />

With longer pressure pipe to channel<br />

■ Polyethylene collector tank<br />

■ With drain plug<br />

■ With connection for the manual membrane<br />

pump R 1½“<br />

■ With mounting set for buoyancy safety<br />

anchoring<br />

■ With 3 horizontal inlet sockets DN 100<br />

Ordering information<br />

ca. 760<br />

flaps for<br />

buoyancy control<br />

stop valve R 2<br />

200<br />

55<br />

drain plug<br />

pump with<br />

cutting mechanism<br />

600<br />

mounting brackets<br />

for mini compressor<br />

mini compressor<br />

R 2<br />

pneumatic control<br />

660<br />

765<br />

■ With 1 horizontal inlet socket with<br />

gradation DN 100/DN 150<br />

■ With ventilation socket DN 100 for<br />

connection to the plastic pipe<br />

■ Pressure pipe connection<br />

With 1 ball backflow stop R 2“<br />

With stop valve R 2“<br />

■ Pump unit<br />

Motor 400 V, 50 Hz<br />

Protection category IP 68<br />

With outside cutting mechanism<br />

■ Pneumatic level switching with pilot tube<br />

and pneumatic control line<br />

■ Switching and warning device<br />

Protection category IP 54<br />

With 1 .5 m cable and CEE plug<br />

With dry contact centralised fault<br />

signal and operating signal<br />

Inc . 4 m pneumatic control line between<br />

the lifting plant and control box<br />

tube sockets Ø48 mm<br />

for connection to<br />

manual-diaphragm pump R 1 ½“<br />

105<br />

210<br />

70<br />

100 120<br />

ventilation<br />

DN 100<br />

switch box plug-in ready<br />

(250x195x100)<br />

connection<br />

pneumatic control<br />

cable (4 m long)<br />

connectionr<br />

centralised<br />

fault signal<br />

motor cable<br />

(4m long)<br />

650<br />

485<br />

400 (Z3) 165<br />

250 (Z2) 58 70<br />

180 (Z1)<br />

Pumps � Waste water lifting plants � Waste water containing faeces<br />

waste water collecting tank<br />

made of polyethylene<br />

í110<br />

cable 1.5 m long<br />

with CEKON-plug 16 A<br />

electr. connection for<br />

mini compressor<br />

í110<br />

í160<br />

300<br />

80<br />

110 100 55<br />

tube sockets Ø48 mm<br />

for connection to<br />

manual-diaphragm pump R 1 ½“<br />

upper inlet socket with<br />

selectable nominal diameter DN 100/DN150<br />

cut off at indents as required<br />

pitot tube<br />

lateral inlet socket DN 100<br />

K9/1


K9/1<br />

Pumps � Waste water lifting plants � Waste water containing faeces<br />

Type Motor rating<br />

Muli-PE-<br />

S-100<br />

mono<br />

Muli-PE-<br />

S-200<br />

mono<br />

P1 P2 Currentconsumption<br />

Characteristics Total<br />

volume<br />

Voltage<br />

Frequency<br />

Revolutions<br />

[kW] [kW] [A] [V] [Hz] [U/<br />

min]<br />

Remark: Maximum temperature of wastewater is only<br />

allowed for a short time .<br />

Waste water lifting plant for free-standing installation<br />

Muli-Series<br />

Inlet<br />

height<br />

Z1<br />

Useable volume Weight Article No.<br />

Inlet<br />

height<br />

Z2<br />

Inlet<br />

height<br />

Z3<br />

Inlet<br />

from<br />

above<br />

[l] [l] [l] [l] [l] [kg]<br />

1,2 0,9 2,3 400 50 2900 80 10 35 50 50 80 0159.03.91<br />

2,5 1,7 4,1 400 50 2900 80 10 35 50 50 85 0175.19.00<br />

Performance parameters<br />

Type Delivery<br />

head<br />

Muli-PE-<br />

S-100 mono<br />

Muli-PE-<br />

S-200 mono<br />

[m] 28<br />

Gesamtförderhöhe H<br />

26<br />

24<br />

22<br />

20<br />

18<br />

16<br />

<strong>14</strong><br />

12<br />

10<br />

8<br />

6<br />

4<br />

2<br />

0<br />

0<br />

0<br />

Leistungsdiagramm Toleranzen ISO 2548/C<br />

Mindestförderstrom DN 50<br />

MULI - PE - S 100<br />

1,8 3,6 5,4 7,2 9 10,8 12,6 <strong>14</strong>,4 16,2 18 19,8 21,6 [m³/h]<br />

0,5 1 1,5 2 2,5 3<br />

Förderstrom Q<br />

MULI - PE - S 200<br />

[l/s]<br />

3,5 4 4,5 5 5,5 6<br />

Delivery flow Q with total delivery head H Conveyance<br />

media temperature<br />

2 m 4 m 6 m 8 m 10 m 12 m <strong>14</strong> m 16 m 18 m 20 m 22 m 24 m Normal<br />

[m] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [°C] [°C]<br />

2 – 18 3,57 3,4 3,2 3,0 2,75 2,43 2,1 1,75 1,3 40 60<br />

2 – 24 5,93 5,65 5,36 5,05 4,72 4,34 3,94 3,47 2,96 2,38 1,73 1,2 40 60<br />

Infobox<br />

Maximum<br />

631<br />

<strong>14</strong><br />

Waste water lifting plants<br />

Waste water containing faeces


<strong>14</strong><br />

Waste water lifting plants<br />

Waste water containing faeces<br />

Waste water lifting plant for free-standing installation<br />

Muli-Series<br />

Muli-PE-S duo<br />

Product information<br />

632<br />

<strong>ACO</strong> product advantages<br />

■ High-grade waste water lifting plant<br />

with submerged motor pump and<br />

cutting mechanism<br />

■ Various inlet heights<br />

■ Low costs via small pressure pipe<br />

profile<br />

■ Areas of application<br />

Renovation of an old building<br />

With longer pressure pipe to channel<br />

Objects containing fluids with solid<br />

or fibrous contents e .g . laundries,<br />

abattoirs<br />

■ Polyethylene collector tank<br />

■ With drain plug<br />

■ With connection for the manual membrane<br />

pump R 1½“<br />

■ With mounting set for buoyancy safety<br />

anchoring<br />

Ordering information<br />

ball retaining<br />

valve R 2"<br />

ca. 910<br />

55<br />

200<br />

750<br />

300<br />

pressure pipe<br />

drain plug<br />

R2<br />

■ With 2 horizontal inlet sockets DN 100/<br />

DN 150<br />

■ With 1 horizontal inlet socket with<br />

gradation DN 100/DN 150<br />

■ With ventilation socket DN 100 for<br />

connection to the plastic pipe<br />

■ Pressure pipe connection<br />

With 2 ball backflow stops R 2“<br />

With 2 stop valves R 2“<br />

■ 2 pump units<br />

Motor 400 V, 50 Hz<br />

Protection category IP 68<br />

With outside cutting mechanism<br />

■ Pneumatic level switching with pilot tube<br />

and pneumatic control line<br />

■ Switching and warning device<br />

Protection category IP 54<br />

With 1 .5 m cable and CEE plug<br />

With dry contact centralised fault<br />

signal and operating signal<br />

Inc . 4 m pneumatic control line between<br />

the lifting plant and control box<br />

connection pneumatic<br />

control cable (4m long)<br />

165<br />

70<br />

pump with cutting mechanism<br />

flaps for<br />

buoyancy control<br />

810<br />

1005<br />

connection<br />

centralised fault signal<br />

Ø160<br />

Ø110<br />

105<br />

210<br />

switch box plug-in ready<br />

(250 x 195 x 100)<br />

motor cable<br />

(4m long)<br />

165<br />

70<br />

650<br />

connection<br />

mini compressor<br />

tube socket Ø48 mm<br />

for connecting to<br />

manual membrane pump R 1 ½“<br />

pneumatic control<br />

124<br />

100<br />

485<br />

58<br />

400 (Z2)<br />

250 (Z1)<br />

ventilation DN100<br />

Pumps � Waste water lifting plants � Waste water containing faeces<br />

cable 1.5 m long with<br />

CEKON-plug 16 A<br />

70 70 124<br />

waste water collecting tank made of polyethylene<br />

55<br />

upper inlet socket with<br />

selectable nominal diameter<br />

DN 100/150<br />

pitot tube<br />

lateral inlet socket with<br />

selectable nominal diameter<br />

DN100/150<br />

K9/1


K9/1<br />

Pumps � Waste water lifting plants � Waste water containing faeces<br />

Type Motor rating<br />

Muli-PE-S-100<br />

duo<br />

Muli-PE-S-200<br />

duo<br />

P1 P2 Currentconsumption<br />

Characteristics Total<br />

volume<br />

Voltage<br />

Frequency<br />

Remark: Maximum temperature of wastewater is only<br />

allowed for a short time .<br />

Revolutions<br />

[kW] [kW] [A] [V] [Hz] [U/<br />

min]<br />

Waste water lifting plant for free-standing installation<br />

Muli-Series<br />

Inlet<br />

height<br />

Z1<br />

Useable volume Weight Article No.<br />

Inlet<br />

height<br />

Z2<br />

Inlet<br />

from<br />

above<br />

[l] [l] [l] [l] [kg]<br />

1,2 0,9 2,3 400 50 2900 105 40 60 60 180 0159.04.24<br />

2,5 1,7 4,1 400 50 2900 105 40 60 60 185 0175.02.67<br />

Performance parameters<br />

Type Delivery<br />

head<br />

Muli-PE-<br />

S-100 duo<br />

Muli-PE-<br />

S-200 duo<br />

[m] 28<br />

Gesamtförderhöhe H<br />

26<br />

24<br />

22<br />

20<br />

18<br />

16<br />

<strong>14</strong><br />

12<br />

10<br />

8<br />

6<br />

4<br />

2<br />

0<br />

0<br />

0<br />

Leistungsdiagramm Toleranzen ISO 2548/C<br />

Mindestförderstrom DN 50<br />

MULI - PE - S 100<br />

1,8 3,6 5,4 7,2 9 10,8 12,6 <strong>14</strong>,4 16,2 18 19,8 21,6 [m³/h]<br />

0,5 1 1,5 2 2,5 3<br />

Förderstrom Q<br />

MULI - PE - S 200<br />

[l/s]<br />

3,5 4 4,5 5 5,5 6<br />

Delivery flow Q with total delivery head H Conveyance<br />

media temperature<br />

2 m 4 m 6 m 8 m 10 m 12 m <strong>14</strong> m 16 m 18 m 20 m 22 m 24 m Normal<br />

[m] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [°C] [°C]<br />

2 – 18 3,57 3,4 3,2 3,0 2,75 2,43 2,1 1,75 1,3 40 60<br />

2 – 24 5,93 5,65 5,36 5,05 4,72 4,34 3,94 3,47 2,96 2,38 1,73 1,2 40 60<br />

Infobox<br />

Maximum<br />

633<br />

<strong>14</strong><br />

Waste water lifting plants<br />

Waste water containing faeces


<strong>14</strong><br />

Waste water lifting plants<br />

Waste water containing faeces<br />

Waste water lifting plant for free-standing installation<br />

Muli-Series<br />

Muli Pro-PE K duo<br />

Product information<br />

634<br />

<strong>ACO</strong> product advantages<br />

■ Large container useable volume<br />

■ Various inlet heights<br />

■ Pilot tube and air bubble injection<br />

ensure high operating safety<br />

■ Suitable for fatty waste water<br />

■ Can be extended to a parallel plant<br />

■ Energy-saving channel impeller pump<br />

■ Adapted to door dimensions: 780 mm<br />

■ Areas of application<br />

Apartment housing<br />

Smaller commercial objects with a<br />

large waste water volume<br />

Behind the grease separator up to<br />

NS 20<br />

For long pressure pipes with large<br />

height differences<br />

■ Polyethylene collector tank<br />

■ With drain plug<br />

■ With connection for the manual membrane<br />

pump R 1½“<br />

■ With mounting set for buoyancy safety<br />

anchoring<br />

■ With 4 horizontal inlet sockets DN 150<br />

■ With 1 vertical inlet sockets DN 150<br />

■ With 1 revision opening, clear diameter:<br />

320 mm<br />

Ordering information<br />

ca. <strong>14</strong>10<br />

*ca. 1530<br />

430<br />

pressure pipe DN 100<br />

Ø108 bis 1<strong>14</strong>,3<br />

special fastening piece DN 100<br />

Y-branch pipe DN 80/80/100<br />

(x DN 100/100/100)<br />

Stop valve<br />

DN 80 (x DN 100)<br />

-accessories-<br />

258<br />

65<br />

drain plug<br />

285 130<br />

260 180<br />

*300 *190<br />

100<br />

Flaps for<br />

buoyancy control<br />

1300<br />

ca. 1500<br />

pneumatic<br />

control<br />

connection R 1 ½<br />

for manual membrane<br />

pump<br />

■ With ventilation socket DN 100 for<br />

connection to the plastic pipe<br />

■ Pressure pipe connection<br />

With 2 special backflow valves DN 80<br />

(DN 100 for MULI Pro-PE K-75 duo)<br />

with short-spell ventilation<br />

With Y-branch pipe<br />

With special mounting piece DN 100<br />

for connection of the pressure<br />

pipe with an external diameter of<br />

108 – 1<strong>14</strong> .3 mm<br />

■ 2 pump units<br />

Motor 400 V, 50 Hz<br />

Protection category IP 68<br />

With shaft and mechanical seal<br />

With channel impeller<br />

■ Pneumatic level switching with pilot tube<br />

and pneumatic control line<br />

■ Separate pilot tube for high alarm<br />

■ Mini compressor for air bubble injection<br />

■ Switching and warning device<br />

Protection category IP 54<br />

With 1 .5 m cable and CEE plug<br />

With dry contact centralised fault<br />

signal and operating signal<br />

Inc . 7 m cabling between the lifting<br />

plant and control box<br />

ventilation<br />

DN100<br />

95<br />

100 95<br />

250<br />

120<br />

maintenance opening<br />

LW 320<br />

215<br />

inlet socket<br />

DN 150<br />

600<br />

800<br />

940<br />

780<br />

special backflow valve<br />

DN80 (x DN 100)<br />

with draining screw<br />

Pumps � Waste water lifting plants � Waste water containing faeces<br />

switch box plug-in ready<br />

connection for ( 250 x 195 x 100 )<br />

potential-free<br />

centralised alarm signals<br />

and operation signals<br />

connection for<br />

emergency power<br />

supplies<br />

750<br />

channel impeller centrifugal pump<br />

grain size 70-90 mm<br />

motor cable<br />

(4m long)<br />

connection<br />

mini compressor<br />

cable 1.5 m long with<br />

CEKON-plug 16 A<br />

connection pneumatic control cable<br />

connection pneumatic control cable<br />

"ALARM 1"<br />

mini compressor<br />

for air bubble injection<br />

K9/1


K9/1<br />

Pumps � Waste water lifting plants � Waste water containing faeces<br />

Type Motor<br />

rating<br />

Muli Pro-PE<br />

K-15 duo<br />

Muli Pro-PE<br />

K-22 duo<br />

Muli Pro-PE<br />

K-30 duo<br />

Muli Pro-PE<br />

K-55 duo<br />

Muli Pro-PE<br />

K-75 duo<br />

P1 P2 Currentconsumption<br />

Characteristics Grain<br />

size<br />

Voltage<br />

Frequency<br />

Revolutions<br />

[kW] [kW] [A] [V] [Hz] [U/<br />

min]<br />

Remark: Maximum temperature of wastewater is only<br />

allowed for a short time .<br />

Waste water lifting plant for free-standing installation<br />

Muli-Series<br />

Total<br />

volume<br />

Inlet<br />

height<br />

Z1<br />

Useable volume Weight Article No.<br />

Inlet<br />

height<br />

Z2<br />

Inlet<br />

height<br />

Z3<br />

Inlet<br />

from<br />

above<br />

[mm] [l] [l] [l] [l] [l] [kg]<br />

2,01 1,5 3,6 400 50 <strong>14</strong>50 70 520 240 305 330 330 275 0175.13.17<br />

2,94 2,2 5,2 400 50 <strong>14</strong>50 70 520 240 305 330 330 285 0175.13.18<br />

3,87 3 6,6 400 50 <strong>14</strong>50 70 520 240 305 330 330 380 0175.13.19<br />

6,71 5,5 11,6 400 50 <strong>14</strong>50 70 520 240 305 330 330 425 0175.13.20<br />

8,97 7,5 15,5 400 50 <strong>14</strong>50 100 520 240 305 330 330 470 0175.13.21<br />

Performance parameters<br />

[m] 20<br />

18<br />

16<br />

<strong>14</strong><br />

12<br />

10<br />

8<br />

6<br />

4<br />

2<br />

0<br />

Leistungsdiagramm Toleranzen ISO 2548/C<br />

n=<strong>14</strong>50 U/min<br />

0 12 24 36 48 60 72 84 96 108 120 132 <strong>14</strong>4 156 168 180 192 [m³/h]<br />

[l/s]<br />

0 5 10 15 20 25 30 35 40 45 50<br />

Förderstrom Q<br />

Gesamtförderhöhe H<br />

Mindestförderstrom DN80<br />

Mindestförderstrom DN100<br />

K-22<br />

K-15<br />

K-30<br />

K-55<br />

K-75<br />

Type Delive-<br />

Delivery flow Q with total delivery head H Conveyance mery<br />

head<br />

dia temperature<br />

4 m 6 m 8 m 10 m 12 m <strong>14</strong> m 16 m 18 m Normal Maximum<br />

[m] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [°C] [°C]<br />

Muli Pro-PE<br />

K-15 duo<br />

Muli Pro-PE<br />

K-22 duo<br />

Muli Pro-PE<br />

K-30 duo<br />

Muli Pro-PE<br />

K-55 duo<br />

Muli Pro-PE<br />

K-75 duo<br />

3 – 8 18,3 11,7 5,8 40 60<br />

3 – 10 24,2 18,5 12,5 5,3 40 60<br />

4 – <strong>14</strong> 33,5 28,4 23,1 16,8 10,3 4,2 40 60<br />

4 – 17 37,3 32,7 28,1 23,1 18,8 <strong>14</strong>,1 9,4 40 60<br />

6 – 18 51,8 46,2 39,2 31,7 23,2 <strong>14</strong>,2 6,8 40 60<br />

Infobox<br />

635<br />

<strong>14</strong><br />

Waste water lifting plants<br />

Waste water containing faeces


<strong>14</strong><br />

Waste water lifting plants<br />

Waste water containing faeces<br />

Waste water lifting plant for free-standing installation<br />

Muli-Series<br />

Muli Pro-PE V duo<br />

Product information<br />

636<br />

<strong>ACO</strong> product advantages<br />

■ Large container useable volume<br />

■ Various inlet heights<br />

■ Pilot tube and air bubble injection<br />

ensure high operating safety<br />

■ Suitable for fatty waste water<br />

■ Can be extended to a parallel plant<br />

■ Blockage-free free flow impeller<br />

■ Adapted to door dimensions: 780 mm<br />

■ Areas of application<br />

Apartment housing<br />

Smaller commercial objects with a<br />

large waste water volume<br />

For waste water with long-fibre<br />

contents<br />

Behind the grease separator up to<br />

NS 15<br />

■ Polyethylene collector tank<br />

■ With drain plug<br />

■ With connection for the manual membrane<br />

pump R 1½“<br />

■ With mounting set for buoyancy safety<br />

anchoring<br />

■ With 4 horizontal inlet sockets DN 150<br />

■ With 1 vertical inlet sockets DN 150<br />

Ordering information<br />

ca. <strong>14</strong>80<br />

258<br />

65<br />

connection R 1 ½<br />

for manual<br />

membrane pump<br />

180 270 160<br />

260<br />

pressure pipe DN 100<br />

325<br />

■ With 1 revision opening, clear diameter:<br />

320 mm<br />

■ With ventilation socket DN 100 for<br />

connection to the plastic pipe<br />

■ Pressure pipe connection<br />

With 2 special backflow valves DN 80<br />

with short-spell ventilation<br />

With Y-branch pipe<br />

With special mounting piece DN 100<br />

for connection of the pressure<br />

pipe with an external diameter of<br />

108 – 1<strong>14</strong> .3 mm<br />

■ 2 pump units<br />

Motor 400 V, 50 Hz<br />

Protection category IP 68<br />

With shaft and mechanical seal<br />

With free flow impeller<br />

■ Pneumatic level switching with pilot tube<br />

and pneumatic control line<br />

■ Separate pilot tube for high alarm<br />

■ Mini compressor for air bubble injection<br />

■ Switching and warning device<br />

Protection category IP 54<br />

With 1 .5 m cable and CEE plug<br />

With dry contact centralised fault<br />

signal and operating signal<br />

Inc . 4 m cabling between the lifting<br />

plant and control box<br />

Ø108 bis 1<strong>14</strong>,3<br />

special fastening piece DN 80/100<br />

Y-branch pipe DN 80/80/100<br />

special backflow valve<br />

DN 80<br />

Stop valve<br />

with draining screw<br />

DN 80<br />

-accessories-<br />

Inlet socket<br />

DN 150<br />

1300<br />

pneumatic<br />

control<br />

flaps for<br />

buoyancy control<br />

ventilation<br />

DN100<br />

maintenance<br />

opening LW 320<br />

ca. <strong>14</strong>40<br />

250<br />

95<br />

100 95<br />

120<br />

600 (Z1)<br />

800 (Z3)<br />

940<br />

215<br />

780<br />

750 (Z2)<br />

Pumps � Waste water lifting plants � Waste water containing faeces<br />

free flow pump grain size 80 mm<br />

switch box plug-in ready<br />

connection for (250 x 195 x 100)<br />

potential-free<br />

centralised alarm signals<br />

and operation signalsl<br />

connection for<br />

emergency power supplies<br />

motor cable<br />

(4m long)<br />

connection<br />

mini compressor<br />

inlet socket<br />

DN 150<br />

cable 1.5 m long with<br />

CEKON-plug 16 A<br />

connection pneumatic control cable<br />

connection pneumatic control cable<br />

"ALARM 1"<br />

mini compressor<br />

for air bubble injection<br />

K9/1


K9/1<br />

Pumps � Waste water lifting plants � Waste water containing faeces<br />

Type Motor rating<br />

Muli Pro-<br />

PE V-15<br />

duo<br />

Muli Pro-<br />

PE V-22<br />

duo<br />

Muli Pro-<br />

PE V-30<br />

duo<br />

Muli Pro-<br />

PE V-40<br />

duo<br />

P1 P2 Currentconsumption<br />

Characteristics Grain<br />

size<br />

Voltage<br />

Frequency<br />

Revolutions<br />

[kW] [kW] [A] [V] [Hz] [U/<br />

min]<br />

Remark: Maximum temperature of wastewater is only<br />

allowed for a short time .<br />

Waste water lifting plant for free-standing installation<br />

Muli-Series<br />

Total<br />

volume<br />

Inlet<br />

height<br />

Z1<br />

Useable volume Weight Article No.<br />

Inlet<br />

height<br />

Z2<br />

Inlet<br />

height<br />

Z3<br />

Inlet<br />

from<br />

above<br />

[mm] [l] [l] [l] [l] [l] [kg]<br />

2,01 1,5 4,1 400 50 <strong>14</strong>50 80 520 240 305 330 330 210 0175.12.89<br />

2,94 2,2 5,2 400 50 3000 80 520 240 305 330 330 215 0175.12.90<br />

3,87 3 7,2 400 50 3000 80 520 240 305 330 330 225 0175.12.91<br />

5,1 4 10,3 400 50 3000 80 520 240 305 330 330 230 0175.12.92<br />

Performance parameters<br />

[m] 15<br />

<strong>14</strong><br />

13<br />

12<br />

11<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

0<br />

Leistungsdiagramm Toleranzen ISO 2548/C<br />

0 1 2 3 4 5 6 7 8 9 10 11 12 13 <strong>14</strong> 15 16 17 18 [l/s]<br />

[m³/h]<br />

0 5 10 15 20 25 30 35 40 45 50 55 60 65<br />

Gesamtförderhöhe H<br />

Mindestförderstrom DN80<br />

Mindestförderstrom DN100<br />

V-22<br />

Förderstrom Q<br />

Type Delive-<br />

Delivery flow Q with total delivery head H Conveyance media temry<br />

head<br />

perature<br />

4 m 6 m 8 m 10 m 12 m Normal Maximum<br />

[m] [l/s] [l/s] [l/s] [l/s] [l/s] [°C] [°C]<br />

Muli Pro-PE<br />

V-15 duo<br />

Muli Pro-PE<br />

V-22 duo<br />

Muli Pro-PE<br />

V-30 duo<br />

Muli Pro-PE<br />

V-40 duo<br />

3 – 6 11,0 3,1 40 60<br />

5 – 7 7,8 40 60<br />

6 – 10 13,15 9,4 4,35 40 60<br />

8 – 12 13,1 9,6 4,7 40 60<br />

V-40<br />

V-30<br />

V-15<br />

Infobox<br />

637<br />

<strong>14</strong><br />

Waste water lifting plants<br />

Waste water containing faeces


<strong>14</strong><br />

Waste water lifting plants<br />

Waste water containing faeces<br />

Waste water lifting plant for free-standing installation<br />

Muli-Series<br />

Muli Pro-PE K parallel<br />

Product information<br />

638<br />

<strong>ACO</strong> product advantages<br />

■ Large container useable volume<br />

■ 8 inlets, 4 inlet heights<br />

■ Pilot tube and air bubble injection<br />

ensure high operating safety<br />

■ Energy-saving channel impeller pump<br />

■ Adapted to door dimensions: 780 mm<br />

■ Areas of application<br />

Commercial or industrial objects with<br />

a large waste water volume<br />

For long pressure pipes with large<br />

height differences<br />

■ Polyethylene collector tank<br />

■ With drain plug<br />

■ With connection for the manual membrane<br />

pump R 1½“<br />

■ With mounting set for buoyancy safety<br />

anchoring<br />

■ With 6 horizontal inlet sockets DN 150<br />

■ With 2 vertical inlet sockets DN 150<br />

■ With 2 revision openings, clear diameter:<br />

320 mm<br />

■ With ventilation socket DN 100 for<br />

connection to the plastic pipe<br />

Ordering information<br />

ca. <strong>14</strong>10<br />

*ca. 1530<br />

260 180 285 130<br />

*300 *190<br />

430<br />

pressure pipe DN 100<br />

Ø108 bis 1<strong>14</strong>,3<br />

65<br />

258<br />

drain plug<br />

100<br />

special fastening piece DN 100<br />

stop valve<br />

DN 80 (x DN 100)<br />

-accessories-<br />

1300<br />

1500<br />

pneumatic control<br />

Flaps for<br />

buoyancy control<br />

connection R 1 ½<br />

for manual membrane pump<br />

■ Pressure pipe connection<br />

With 2 special backflow valves DN 80<br />

(DN 100 for MULI Pro-PE K-75 Parallel)<br />

with short-spell ventilation<br />

With Y-branch pipe<br />

With special mounting piece DN 100<br />

for connection of the pressure<br />

pipe with an external diameter of<br />

108 – 1<strong>14</strong> .3 mm<br />

■ 2 pump units<br />

Motor 400 V, 50 Hz<br />

Protection category IP 68<br />

With shaft and mechanical seal<br />

With channel impeller<br />

■ Pneumatic level switching with pilot tube<br />

and pneumatic control line<br />

■ Separate pilot tube for high alarm<br />

■ Mini compressor for air bubble injection<br />

■ Switching and warning device<br />

Protection category IP 54<br />

With 1 .5 m cable and CEE plug<br />

With dry contact centralised fault<br />

signal and operating signal<br />

Inc . 7 m cabling between the lifting<br />

plant and control box<br />

100<br />

250<br />

95<br />

maintenance opening<br />

LW 320<br />

special backflow valve<br />

DN80 (x DN 100)<br />

with draining screw<br />

inlet socket<br />

DN 150<br />

120<br />

600 (Z1)<br />

800 (Z3)<br />

940<br />

95<br />

ventilation DN100<br />

overflow<br />

DN 150<br />

215<br />

860<br />

inlet socket<br />

DN 150<br />

1640<br />

Pumps � Waste water lifting plants � Waste water containing faeces<br />

switch box plug-in ready<br />

connection for (250 x 195 x 100)<br />

potential-free<br />

centralised alarm signals<br />

and operation signals<br />

connection for<br />

emergency power<br />

supplies<br />

780 780<br />

channel impeller centrifugal pump<br />

grain size 70-90 mm<br />

motor cable<br />

(4m long )<br />

Y-branch pipe DN 80/80/100<br />

(x DN 100/100/100)<br />

connection<br />

mini compressor<br />

750 (Z2)<br />

cable 1.5 m long with<br />

CEKON-connector 16 A<br />

connection pneumatic control cable<br />

connection pneumatic control cable<br />

"ALARM 1"<br />

mini compressor<br />

for air bubble injection<br />

K9/1


K9/1<br />

Pumps � Waste water lifting plants � Waste water containing faeces<br />

Type Motor<br />

rating<br />

Muli Pro-<br />

PE K-15<br />

parallel<br />

Muli Pro-<br />

PE K-22<br />

parallel<br />

Muli Pro-<br />

PE K-30<br />

parallel<br />

Muli Pro-<br />

PE K-55<br />

parallel<br />

Muli Pro-<br />

PE K-75<br />

parallel<br />

P1 P2 Currentconsumption<br />

Characteristics Grain<br />

size<br />

Voltage<br />

Frequency<br />

Revolutions<br />

[kW] [kW] [A] [V] [Hz] [U/<br />

min]<br />

Remark: Maximum temperature of wastewater is only<br />

allowed for a short time .<br />

Waste water lifting plant for free-standing installation<br />

Muli-Series<br />

Total<br />

volume<br />

Inlet<br />

height<br />

Z1<br />

Useable volume Weight Article No.<br />

Inlet<br />

height<br />

Z2<br />

Inlet<br />

height<br />

Z3<br />

Inlet<br />

from<br />

above<br />

[mm] [l] [l] [l] [l] [l] [kg]<br />

2,01 1,5 3,6 400 50 <strong>14</strong>50 70 1040 480 610 660 660 315 0175.13.23<br />

2,94 2,2 5,2 400 50 <strong>14</strong>50 70 1040 480 610 660 660 325 0175.13.24<br />

3,87 3 6,6 400 50 <strong>14</strong>50 70 1040 480 610 660 660 420 0175.13.25<br />

6,71 5,5 11,6 400 50 <strong>14</strong>50 70 1040 480 610 660 660 465 0175.13.26<br />

8,97 7,5 15,5 400 50 <strong>14</strong>50 100 1040 480 610 660 660 510 0175.13.27<br />

Performance parameters<br />

[m] 20<br />

18<br />

16<br />

<strong>14</strong><br />

12<br />

10<br />

8<br />

6<br />

4<br />

2<br />

0<br />

Leistungsdiagramm Toleranzen ISO 2548/C<br />

n=<strong>14</strong>50 U/min<br />

0 12 24 36 48 60 72 84 96 108 120 132 <strong>14</strong>4 156 168 180 192 [m³/h]<br />

[l/s]<br />

0 5 10 15 20 25 30 35 40 45 50<br />

Förderstrom Q<br />

Gesamtförderhöhe H<br />

Mindestförderstrom DN80<br />

Mindestförderstrom DN100<br />

K-22<br />

K-15<br />

K-30<br />

K-55<br />

K-75<br />

Type Delive-<br />

Delivery flow Q with total delivery head H Conveyance mery<br />

head<br />

dia temperature<br />

4 m 6 m 8 m 10 m 12 m <strong>14</strong> m 16 m 18 m Normal Maximum<br />

[m] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [l/s] [°C] [°C]<br />

Muli Pro-PE<br />

K-15 parallel<br />

Muli Pro-PE<br />

K-22 parallel<br />

Muli Pro-PE<br />

K-30 parallel<br />

Muli Pro-PE<br />

K-55 parallel<br />

Muli Pro-PE<br />

K-75 parallel<br />

3 – 8 18,3 11,7 5,8 40 60<br />

3 – 10 24,2 18,5 12,5 5,3 40 60<br />

4 – <strong>14</strong> 33,5 28,4 23,1 16,8 10,3 4,2 40 60<br />

4 – 17 37,3 32,7 28,1 23,1 18,8 <strong>14</strong>,1 9,4 40 60<br />

6 – 18 51,8 46,2 39,2 31,7 23,2 <strong>14</strong>,2 6,8 40 60<br />

Infobox<br />

639<br />

<strong>14</strong><br />

Waste water lifting plants<br />

Waste water containing faeces


<strong>14</strong><br />

Waste water lifting plants<br />

Waste water containing faeces<br />

Waste water lifting plant for free-standing installation<br />

Muli-Series<br />

Muli Pro-PE V parallel<br />

Product information<br />

640<br />

<strong>ACO</strong> product advantages<br />

■ Large container useable volume<br />

■ 8 inlets, 4 inlet heights<br />

■ Pilot tube and air bubble injection<br />

ensure high operating safety<br />

■ Blockage-free free flow impeller<br />

■ Adapted to door dimensions: 780 mm<br />

■ Areas of application<br />

Commercial or industrial objects with<br />

a large waste water volume<br />

Apartment housing<br />

Behind the grease separator up to<br />

NS 20<br />

For waste water with long-fibre<br />

contents<br />

■ Polyethylene collector tank<br />

■ With drain plug<br />

■ With connection for the manual membrane<br />

pump R 1½“<br />

■ With mounting set for buoyancy safety<br />

anchoring<br />

■ With 6 horizontal inlet sockets DN 150<br />

■ With 2 vertical inlet sockets DN 150<br />

■ With 2 revision openings, clear diameter:<br />

320 mm<br />

Ordering information<br />

ca. <strong>14</strong>70<br />

65<br />

258<br />

260 180 285 130<br />

drain plug<br />

430<br />

Flaps for<br />

buoyancy control<br />

pressure pipe DN 100<br />

325<br />

connection R 1 ½<br />

for manual<br />

membrane pump<br />

Ø108 bis 1<strong>14</strong>,3<br />

special fastening piece<br />

DN 100<br />

stop valve DN 80<br />

-accessories-<br />

1300<br />

■ With ventilation socket DN 100 for<br />

connection to the plastic pipe<br />

■ Pressure pipe connection<br />

With 2 special backflow valves DN 80<br />

with short-spell ventilation<br />

With Y-branch pipe<br />

With special mounting piece DN 100<br />

for connection of the pressure<br />

pipe with an external diameter of<br />

108 – 1<strong>14</strong> .3 mm<br />

■ 2 pump units<br />

Motor 400 V, 50 Hz<br />

Protection category IP 68<br />

With shaft and mechanical seal<br />

With blockage-free free flow impeller<br />

■ Pneumatic level switching with pilot tube<br />

and pneumatic control line<br />

■ Separate pilot tube for high alarm<br />

■ Mini compressor for air bubble injection<br />

■ Switching and warning device<br />

Protection category IP 54<br />

With 1 .5 m cable and CEE plug<br />

With dry contact centralised fault<br />

signal and operating signal<br />

Inc . 4 m cabling between the lifting<br />

plant and control box<br />

100<br />

95<br />

120<br />

600 (Z1)<br />

800 (Z3)<br />

940<br />

95<br />

Inlet socket<br />

DN 150<br />

pneumatic<br />

control ventilation DN100<br />

250<br />

overflow<br />

DN 150<br />

215<br />

inlet socket<br />

DN 150<br />

maintenance opening<br />

LW 320<br />

860<br />

special backflow valve<br />

DN 80 (x DN 100)<br />

with draining screw<br />

1640<br />

Pumps � Waste water lifting plants � Waste water containing faeces<br />

switch box plug-in ready<br />

connection for (250 x 195 x 100)<br />

potential-free<br />

centralised alarm signals<br />

and operation signals<br />

connection for<br />

emergency power<br />

supplies<br />

780 780<br />

free flow pump<br />

grain size 80 mm<br />

motor cable<br />

(4m long)<br />

Y-branch pipe DN 80/80/100<br />

connection<br />

mini compressor<br />

750 (Z2)<br />

cable 1.5 m long with<br />

CEKON-plug 16 A<br />

connection pneumatic control cable<br />

connection pneumatic control cable<br />

"ALARM 1"<br />

mini compressor<br />

for air bubble injection<br />

K9/1


K9/1<br />

Pumps � Waste water lifting plants � Waste water containing faeces<br />

Type Motor<br />

rating<br />

Muli Pro-<br />

PE V-15<br />

parallel<br />

Muli Pro-<br />

PE V-22<br />

parallel<br />

Muli Pro-<br />

PE V-30<br />

parallel<br />

Muli Pro-<br />

PE V-40<br />

parallel<br />

P1 P2 Currentconsumption<br />

Characteristics Grain<br />

size<br />

Voltage<br />

Frequency<br />

Revolutions<br />

[kW] [kW] [A] [V] [Hz] [U/<br />

min]<br />

Remark: Maximum temperature of wastewater is only<br />

allowed for a short time .<br />

Waste water lifting plant for free-standing installation<br />

Muli-Series<br />

Total<br />

volume<br />

Inlet<br />

height<br />

Z1<br />

Useable volume Weight Article No.<br />

Inlet<br />

height<br />

Z2<br />

Inlet<br />

height<br />

Z3<br />

Inlet<br />

from<br />

above<br />

[mm] [l] [l] [l] [l] [l] [kg]<br />

2,01 1,5 4,1 400 50 <strong>14</strong>50 80 1040 480 610 660 660 210 0175.12.94<br />

2,94 2,2 5,2 400 50 3000 80 1040 480 610 660 660 215 0175.12.95<br />

3,87 3 7,2 400 50 3000 80 1040 480 610 660 660 225 0175.12.96<br />

5,1 4 10,3 400 50 3000 80 1040 480 610 660 660 230 0175.12.97<br />

Performance parameters<br />

[m] 20<br />

18<br />

16<br />

<strong>14</strong><br />

12<br />

10<br />

8<br />

6<br />

4<br />

2<br />

0<br />

Leistungsdiagramm Toleranzen ISO 2548/C<br />

n=<strong>14</strong>50 U/min<br />

0 12 24 36 48 60 72 84 96 108 120 132 <strong>14</strong>4 156 168 180 192 [m³/h]<br />

[l/s]<br />

0 5 10 15 20 25 30 35 40 45 50<br />

Förderstrom Q<br />

Gesamtförderhöhe H<br />

Mindestförderstrom DN80<br />

Mindestförderstrom DN100<br />

K-22<br />

K-15<br />

K-30<br />

K-55<br />

Type Delive-<br />

Delivery flow Q with total delivery head H Conveyance media temry<br />

head<br />

perature<br />

4 m 6 m 8 m 10 m 12 m Normal Maximum<br />

[m] [l/s] [l/s] [l/s] [l/s] [l/s] [°C] [°C]<br />

Muli Pro-PE<br />

V-15 parallel<br />

Muli Pro-PE<br />

V-22 parallel<br />

Muli Pro-PE<br />

V-30 parallel<br />

Muli Pro-PE<br />

V-40 parallel<br />

K-75<br />

3 – 6 11,0 3,1 40 60<br />

5 – 7 7,8 40 60<br />

6 – 10 13,15 9,4 4,35 40 60<br />

8 – 12 13,1 9,6 4,7 40 60<br />

Infobox<br />

641<br />

<strong>14</strong><br />

Waste water lifting plants<br />

Waste water containing faeces


<strong>14</strong><br />

Waste water lifting plants<br />

Waste water containing faeces<br />

Waste water lifting plant for free-standing installation<br />

Muli-Series<br />

Muli Pro 1.x VA duo<br />

Product information<br />

642<br />

<strong>ACO</strong> product advantages<br />

■ Forced activation upon „level high“<br />

ensures high operating security<br />

■ Suitable for fatty waste water<br />

■ Pilot tube and air bubble injection<br />

ensure high operating safety<br />

■ Blockage-free free flow impeller<br />

■ Areas of application<br />

Apartment housing<br />

Smaller commercial objects with a<br />

large waste water volume<br />

For waste water with long-fibre<br />

contents<br />

Behind the grease separator up to<br />

NS 10<br />

■ Stainless steel collector tank, material<br />

grade 316<br />

■ With drain plug<br />

■ With connection for the manual membrane<br />

pump R 1½“<br />

■ With mounting set for buoyancy safety<br />

anchoring<br />

■ Choice of revision opening or inlet<br />

socket<br />

Ordering information<br />

special fastening piece<br />

DN 80/100<br />

Y-branch duct<br />

DN 80/80/80<br />

stop valve DN 80<br />

-accessories-<br />

special backflow valve<br />

DN 80 with draining screw<br />

free flow pump<br />

grain size 80 mm<br />

638<br />

1000<br />

265<br />

10<br />

300<br />

125<br />

275<br />

10<br />

pressure pipe DN 100<br />

750<br />

With 2 revision openings diameter:<br />

285 mm or with horizontal inlet<br />

socket DN 100/DN 150<br />

■ Ventilation socket DN 100 for connection<br />

to the plastic pipe<br />

■ Pressure pipe connection<br />

Via 2 special backflow valves DN 80<br />

with short-spell ventilation<br />

With an integrated special mounting<br />

piece for connection of the pressure<br />

pipe with an external diameter of<br />

108 – 1<strong>14</strong> .3 mm<br />

■ 2 pump units<br />

Motor 400 V, 50 Hz<br />

Protection category IP 68<br />

With shaft and mechanical seal<br />

With free flow impeller<br />

■ Pneumatic level switching with pilot tube<br />

and pneumatic control line<br />

■ Separate pilot tube for high alarm<br />

■ Mini compressor for air bubble injection<br />

■ Switching and warning device<br />

Protection category IP 54<br />

With 1 .5 m cable and CEE plug<br />

With dry contact centralised fault<br />

signal and operating signal<br />

Inc . 4 m cabling between the lifting<br />

plant and control box<br />

Ø108 bis 1<strong>14</strong>,3<br />

160 160<br />

688<br />

333<br />

ca. <strong>14</strong>75<br />

mini compressor<br />

for air bubble injection<br />

inlet DN 100<br />

clamping flange<br />

125<br />

maintenance opening Rd 185<br />

one or more inlet DN 100<br />

or DN 150<br />

right, left or on both sides<br />

ventilation DN100<br />

Pumps � Waste water lifting plants � Waste water containing faeces<br />

260 180 270 160<br />

48<br />

1000<br />

drain plug R 1 ½<br />

and attachment for manual membrane pump<br />

switch box plug-in ready<br />

connection for (250 x 195 x 100)<br />

potential-free<br />

centralised alarm signals<br />

and operation signals<br />

connection for<br />

emergency power supplies<br />

motor cable<br />

(4m long)<br />

cable 1.5 m long with<br />

CEKON-plug 16 A<br />

connection<br />

pneumatic control cable<br />

connection<br />

pneumatic control cable<br />

"ALARM 1"<br />

connection<br />

mini compressor<br />

K9/1


K9/1<br />

Pumps � Waste water lifting plants � Waste water containing faeces<br />

Type Motor rating<br />

Muli Pro 1 .1<br />

VA duo<br />

Muli Pro 1 .2<br />

VA duo<br />

Muli Pro 1 .3<br />

VA duo<br />

Muli Pro 1 .4<br />

VA duo<br />

P1 P2 Current<br />

consumption<br />

Characteristics Grain<br />

size<br />

Voltage Frequency<br />

Remark: Maximum temperature of wastewater is only<br />

allowed for a short time .<br />

Waste water lifting plant for free-standing installation<br />

Muli-Series<br />

Total<br />

volume<br />

Useable<br />

volume<br />

Inlet<br />

from<br />

above<br />

[kW] [kW] [A] [V] [Hz] [mm] [l] [l] [kg]<br />

Weight Article No.<br />

2,01 1,5 4,1 400 50 80 270 155 210 0175.06.69<br />

2,94 2,2 5,2 400 50 80 270 155 215 0175.06.70<br />

3,87 3 7,2 400 50 80 270 155 225 0175.06.71<br />

5,1 4 10,3 400 50 80 270 155 230 0175.06.72<br />

Performance parameters<br />

[m] 17<br />

16<br />

15<br />

<strong>14</strong><br />

13<br />

12<br />

11<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

0<br />

Leistungsdiagramm Toleranzen ISO 2548/C<br />

0 1 2 3 4 5 6 7 8 9 10 11 12 13 <strong>14</strong> 15 16 17 18 [l/s]<br />

[m³/h]<br />

0 5 10 15 20 25 30 35 40 45 50 55 60 65<br />

Gesamtförderhöhe H<br />

Mindestförderstrom DN80<br />

Mindestförderstrom DN100<br />

MULI-PRO-1.4 VA-duo<br />

MULI-PRO-1.3 VA-duo<br />

MULI-PRO-1.2 VA-duo<br />

Förderstrom Q<br />

MULI-PRO-1.1 VA-duo<br />

Type Delive-<br />

Delivery flow Q with total delivery head H Conveyance media temry<br />

head<br />

perature<br />

4 m 6 m 8 m 10 m 12 m Normal Maximum<br />

[m] [l/s] [l/s] [l/s] [l/s] [l/s] [°C] [°C]<br />

Muli Pro 1 .1<br />

VA duo<br />

Muli Pro 1 .2<br />

VA duo<br />

Muli Pro 1 .3<br />

VA duo<br />

Muli Pro 1 .4<br />

VA duo<br />

3 – 6 11,0 3,1 40 60<br />

5 – 7 7,8 40 60<br />

6 – 10 13,15 9,4 4,35 40 60<br />

8 – 12 13,1 9,6 4,7 40 60<br />

Infobox<br />

643<br />

<strong>14</strong><br />

Waste water lifting plants<br />

Waste water containing faeces


<strong>14</strong><br />

Waste water lifting plants<br />

Waste water containing faeces<br />

Waste water lifting plant for free-standing installation<br />

Muli-Series<br />

Muli Pro 2.x VA duo<br />

Product information<br />

644<br />

<strong>ACO</strong> product advantages<br />

■ Forced activation upon „level high“<br />

ensures high operating security<br />

■ Suitable for fatty waste water<br />

■ Pilot tube and air bubble injection<br />

ensure high operating safety<br />

■ Blockage-free free flow impeller<br />

■ Areas of application<br />

Apartment housing<br />

Behind the grease separator up to<br />

NS 20<br />

For municipal and industrial waste<br />

water<br />

■ Stainless steel collector tank, material<br />

grade 316<br />

■ With drain plug<br />

■ With connection for the manual membrane<br />

pump R 1½“<br />

■ With mounting set for buoyancy safety<br />

anchoring<br />

■ Choice of revision opening or inlet<br />

socket<br />

Ordering information<br />

special fastening piece<br />

DN 80/100<br />

Y-branch duct<br />

DN 80/80/80<br />

special backflow valve<br />

DN 80 with draining screw<br />

on both sides - inlet<br />

clamping flange DN 150<br />

(blindly locked)<br />

free flow pump<br />

grain size 80 mm<br />

938<br />

830<br />

1000<br />

500<br />

300<br />

125<br />

275<br />

10<br />

10<br />

pressure pipe DN 100<br />

750<br />

160 160<br />

With 2 revision openings diameter:<br />

285 mm or with horizontal inlet<br />

socket DN 100/DN 150<br />

■ Ventilation socket DN 100 for connection<br />

to the plastic pipe<br />

■ Pressure pipe connection<br />

Via 2 special backflow valves DN 80<br />

with short-spell ventilation<br />

With an integrated special mounting<br />

piece for connection of the pressure<br />

pipe with an external diameter of<br />

108 – 1<strong>14</strong> .3 mm<br />

■ 2 pump units<br />

Motor 400 V, 50 Hz<br />

Protection category IP 68<br />

With shaft and mechanical seal<br />

With free flow impeller<br />

■ Pneumatic level switching with pilot tube<br />

and pneumatic control line<br />

■ Separate pilot tube for high alarm<br />

■ Mini compressor for air bubble injection<br />

■ Switching and warning device<br />

Protection category IP 54<br />

With 1 .5 m cable and CEE plug<br />

With dry contact centralised fault<br />

signal and operating signal<br />

Inc . 4 m cabling between the lifting<br />

plant and control box<br />

Ø108 up to 1<strong>14</strong>,3<br />

stop valve<br />

DN 80<br />

-accessories-<br />

265<br />

333<br />

988<br />

ca. 1600<br />

mini compressor<br />

for air bubble injection<br />

inlet DN 100<br />

clamping flange<br />

125<br />

maintenance opening Rd 185<br />

one or more<br />

inlet DN 100 or DN 150<br />

right, left or on both side<br />

ventilation DN100<br />

1000<br />

Pumps � Waste water lifting plants � Waste water containing faeces<br />

260 180 270 160<br />

48<br />

drain plug R 1 ½<br />

and attachment for manual membrane pump<br />

switch box plug-in ready<br />

connection for (250 x 195 x 100)<br />

potential-free<br />

centralised alarm signals<br />

and operation signals<br />

connection for<br />

emergency power supplies<br />

motor cable<br />

(4m long)<br />

connection<br />

mini compressor<br />

cable 1.5 m long with<br />

CEKON-plug 16 A<br />

connection<br />

pneumatic control cable<br />

connection<br />

pneumatic control cable<br />

"ALARM 1"<br />

K9/1


K9/1<br />

Pumps � Waste water lifting plants � Waste water containing faeces<br />

Type Motor rating<br />

Muli Pro 2 .1<br />

VA duo<br />

Muli Pro 2 .2<br />

VA duo<br />

Muli Pro 2 .3<br />

VA duo<br />

Muli Pro 2 .4<br />

VA duo<br />

P1 P2 Current<br />

consumption<br />

Characteristics Grain<br />

size<br />

Voltage Frequency<br />

Remark: Maximum temperature of wastewater is only<br />

allowed for a short time .<br />

Waste water lifting plant for free-standing installation<br />

Muli-Series<br />

Total<br />

volume<br />

Useable volume Weight Article No.<br />

Inlet<br />

height<br />

Z1<br />

Inlet<br />

from<br />

above<br />

[kW] [kW] [A] [V] [Hz] [mm] [l] [l] [l] [kg]<br />

2,01 1,5 4,1 400 50 80 365 185 245 290 0175.06.74<br />

2,94 2,2 5,2 400 50 80 365 185 245 295 0175.06.75<br />

3,87 3 7,2 400 50 80 365 185 245 305 0175.06.76<br />

5,1 4 10,3 400 50 80 365 185 245 310 0175.06.77<br />

Performance parameters<br />

[m] 17<br />

16<br />

15<br />

<strong>14</strong><br />

13<br />

12<br />

11<br />

10<br />

9<br />

8<br />

7<br />

6<br />

5<br />

4<br />

3<br />

2<br />

1<br />

0<br />

Leistungsdiagramm Toleranzen ISO 2548/C<br />

0 1 2 3 4 5 6 7 8 9 10 11 12 13 <strong>14</strong> 15 16 17 18 [l/s]<br />

[m³/h]<br />

0 5 10 15 20 25 30 35 40 45 50 55 60 65<br />

Gesamtförderhöhe H<br />

Mindestförderstrom DN80<br />

Mindestförderstrom DN100<br />

MULI-PRO-2.4 VA-duo<br />

MULI-PRO-2.3 VA-duo<br />

MULI-PRO-2.2 VA-duo<br />

Förderstrom Q<br />

MULI-PRO-2.1 VA-duo<br />

Type Delive-<br />

Delivery flow Q with total delivery head H Conveyance media temry<br />

head<br />

perature<br />

4 m 6 m 8 m 10 m 12 m Normal Maximum<br />

[m] [l/s] [l/s] [l/s] [l/s] [l/s] [°C] [°C]<br />

Muli Pro 2 .1<br />

VA duo<br />

Muli Pro 2 .2<br />

VA duo<br />

Muli Pro 2 .3<br />

VA duo<br />

Muli Pro 2 .4<br />

VA duo<br />

3 – 6 11,0 3,1 40 60<br />

5 – 7 7,8 40 60<br />

6 – 10 13,15 9,4 4,35 40 60<br />

8 – 12 13,1 9,6 4,7 40 60<br />

Infobox<br />

645<br />

<strong>14</strong><br />

Waste water lifting plants<br />

Waste water containing faeces


<strong>14</strong><br />

Waste water lifting plants<br />

Waste water containing faeces<br />

Waste water lifting plant for free-standing installation<br />

Muli-Series<br />

Accessories<br />

10<br />

15<br />

Ø120<br />

Ø110<br />

Ø174<br />

Ø160<br />

12<br />

15<br />

345<br />

646<br />

315<br />

123<br />

315<br />

<strong>14</strong>0<br />

176<br />

226<br />

Ø160<br />

180<br />

Ø200<br />

190<br />

Ø70<br />

55<br />

Ø160<br />

180<br />

Ø133<br />

80<br />

Ø186<br />

108<br />

R 1 ½“<br />

Pumps � Waste water lifting plants � Waste water containing faeces<br />

Designation compatible with Description Article No.<br />

Inlet valve DN 100<br />

Inlet valve DN 150<br />

■ Waste water lifting plants<br />

■ Polyethylene grease separator<br />

■ Polyethylene starch separator<br />

■ Waste water lifting plants<br />

■ Polyethylene grease separator<br />

■ Polyethylene starch separator<br />

Stop valve DN 80 ■ Waste water lifting plants<br />

Stop valve DN 100 ■ Waste water lifting plants<br />

Fastening parts kit<br />

Fastening parts kit<br />

■ Stop valve<br />

0159 .09 .89<br />

■ Stop valve<br />

0159 .09 .90<br />

Stop valve R 1½“ ■ Waste water lifting plants<br />

Stop valve DN 80 ■ Muli-Star MDS1/MWS1<br />

■ PVC<br />

■ Construction length: 176 mm<br />

■ Weight: 2 .75 kg<br />

■ PVC<br />

■ Construction length: 226 mm<br />

■ Weight: 6 .5 kg<br />

■ Cast iron<br />

■ For pressure pipe<br />

■ Construction length: 180 mm<br />

■ Weight: 21 kg<br />

■ Cast iron<br />

■ For pressure pipe<br />

■ Construction length: 190 mm<br />

■ Weight: 32 kg<br />

■ 8 screws and nuts<br />

■ 1 sealing<br />

■ 8 screws and nuts<br />

■ 1 sealing<br />

■ For the manual membrane<br />

pump<br />

■ Cast iron<br />

■ 8 screws and nuts<br />

■ 1 sealing DN 80<br />

■ Construction length: 180 mm<br />

■ Weight: 21 kg<br />

0175.13.84<br />

0175.13.85<br />

0159.09.89<br />

0159.09.90<br />

0159.00.19<br />

0159.00.20<br />

0159.10.12<br />

0154.51.93<br />

K9/1


K9/1<br />

Pumps � Waste water lifting plants � Waste water containing faeces<br />

430<br />

116 (60 T)<br />

Hupe<br />

„AUS“<br />

Hupe<br />

„AUS“<br />

Störung<br />

Summer<br />

Störung<br />

Summer<br />

Test<br />

116 (60 T)<br />

90<br />

Test<br />

240 225<br />

Rp 1 1/2<br />

170<br />

110<br />

139<br />

DN<br />

Ø265<br />

Ø285<br />

65<br />

45<br />

116<br />

116<br />

470<br />

Ø70<br />

Ø90<br />

Ø100<br />

(montiert)<br />

45<br />

Waste water lifting plant for free-standing installation<br />

Muli-Series<br />

Designation compatible with Description Article No.<br />

Signal device (network<br />

dependent)<br />

Signal device (network<br />

independent)<br />

Air bubble injection<br />

for level switching<br />

Manual membrane<br />

pump R 1½“<br />

Three-way stopcock<br />

R 1½“<br />

Horn<br />

Flashing light<br />

Inlet socket ■ Muli-Pro VA<br />

O-ring<br />

■ Automatic faeces backflow<br />

systems Quatrix-K Type 3F<br />

■ Sinkamat-S/-Z<br />

■ Muli polyethylene duo<br />

■ Muli polyethylene S mono/duo<br />

■ All Multi-Pro waste water lifting<br />

plants<br />

■ Suspension plant mono/duo<br />

■ Automatic faeces backflow<br />

systems Quatrix-K Type 3F<br />

■ Sinkamat-S/-Z<br />

■ Muli polyethylene S mono/duo<br />

■ All Multi-Pro waste water lifting<br />

plants<br />

■ Suspension plant mono/duo<br />

■ Muli polyethylene S mono/duo<br />

■ Muli polyethylene duo<br />

■ Waste water lifting plants<br />

■ Waste water lifting plants<br />

■ Alarm device with dry contact<br />

for fault signal<br />

■ Alarm device with dry contact<br />

for fault signal<br />

■ Fäkablock II<br />

■ Muli series<br />

■ Visual and acoustic<br />

■ Network dependent<br />

■ Without pickup<br />

■ With dry contact for fault signal<br />

level<br />

■ With 1 m connecting cable and<br />

angled three-wire plug<br />

■ Visual and acoustic<br />

■ Self-charging<br />

■ Without pickup<br />

■ With dry contact for fault signal<br />

level<br />

■ With acoustic deletion<br />

■ With 1 m connecting cable and<br />

angled three-wire plug<br />

■ For increased operation safety<br />

when using float cover development<br />

(e .g . grease separator)<br />

■ Pilot tube with mini compressor<br />

230 V<br />

■ For wall mounting<br />

■ Inc . hose<br />

Clear diameter: 48 x 80 mm<br />

■ Inc . hose clips<br />

Clear diameter: 50 x 70 mm<br />

Width: 12 mm<br />

2 pieces required<br />

■ For the manual membrane<br />

pump<br />

■ 230 V<br />

■ Height: 78 mm<br />

0159.12.30<br />

0159.12.31<br />

Mono plant 0159.00.47<br />

Duo plant 0159.00.48<br />

0175.23.73<br />

0159.10.<strong>14</strong><br />

0178.61.94<br />

■ 230 V<br />

0178.62.08<br />

■ For lateral inlet to waste water<br />

lifting plant<br />

■ As additional components for<br />

the pressure pipe DN 80<br />

DN 100 0175.07.58<br />

DN 150 0175.07.61<br />

0159.37.97<br />

647<br />

<strong>14</strong><br />

Waste water lifting plants<br />

Waste water containing faeces