11.01.2013 Views

Subject: Model i1470C Ice Machine Specifications - Manitowoc Ice

Subject: Model i1470C Ice Machine Specifications - Manitowoc Ice

Subject: Model i1470C Ice Machine Specifications - Manitowoc Ice

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Manitowoc</strong><br />

Parts & Service Communicator<br />

<strong>Subject</strong>: <strong>Model</strong> <strong>i1470C</strong> <strong>Ice</strong> <strong>Machine</strong> <strong>Specifications</strong><br />

General <strong>Specifications</strong><br />

<strong>i1470C</strong> <strong>Ice</strong> <strong>Machine</strong> Head Section with a iCVD1495 Condensing Unit<br />

Refrigerant Charge (R-404A) 12.75 lbs (5.8 kg)<br />

Additional refrigerant required for ice machines with 51’ to 100’ (15m - 30m)<br />

Line Set - 2 lbs (907g)<br />

Total charge for ice machines with 51’ to 100’ (15m - 30m) Line Set 14.75 lbs. (6.7 kg)<br />

Heat of Rejection (Btu/Hr) Air Conditioning - 19,000 Peak - 22,000<br />

High Pressure Cut-Out Cut-In - 300 psig Cut-Out - 450 psig<br />

Low Pressure Control Cut-In - 35 psig Cut-Out - 12 psig<br />

Fan Cycle Control Cut-In - 250 psig Cut-Out - 200 psig<br />

<strong>Ice</strong> Making Water Inlet 3/8" FPT (Female Pipe Thread)<br />

<strong>Ice</strong> Making Water Drain<br />

Temperature - Minimum 35°F (2°C) Maximum 90°F (32.2°C)<br />

1/2" FPT (Female Pipe Thread)<br />

Potable Water 20.1 gallons (76 liters) per 100 lbs (45kgs) of ice<br />

Compressor: Nominal Rating 1.75 HP<br />

Line Set RC25 - RC35 - RC55 Suction Line 3/4” (19.1mm) Liquid Line 1/2” (12.7mm)<br />

Operating Temperatures -<br />

<strong>i1470C</strong><br />

Minimum 35°F (2°C) Maximum 110°F (43°C)<br />

iCVD1495 Minimum -20°F (-29°C) Maximum 130°F (54°C)<br />

Voltage -<br />

<strong>i1470C</strong><br />

iCVD1495<br />

Installation on a <strong>Manitowoc</strong> Bin<br />

115/60/1<br />

Max Fuse - 15 amp<br />

Total amps - 1.1<br />

208-230/60/1<br />

Max Fuse - 20 amp<br />

Total amps - 20.0<br />

208-230/60/1<br />

Max Fuse - 15 amp<br />

Total amps - 0.8<br />

208-230/60/3<br />

Max Fuse - 15 amp<br />

Total amps - 15.0<br />

<strong>Manitowoc</strong> <strong>Ice</strong>, 2110 S. 26th St., P.O. Box 1720, <strong>Manitowoc</strong>, WI 54221-1720, Tel: 920-682-0161, www.manitowocice.com<br />

230/50/1<br />

Max Fuse - 15 amp<br />

Total amps - 1.5<br />

230/50/1<br />

Max Fuse - 15 amp<br />

Total amps - 15.0<br />

Outside Cabinet Dimensions<br />

<strong>i1470C</strong><br />

Height - 29.5" (749 mm) Width - 30" (762 mm) Depth - 24.5" (622 mm)<br />

iCVD1495 Height - 25.75" (654 mm) Width - 34.5" (876 mm) Depth - 24.13" (613 mm)<br />

Energy Usage (Kwh / 100 lbs) iD1472C - Dice Cube iY1474C - Half Dice Cube<br />

90°/70° F (32°/2° C) 4.81 4.62<br />

<strong>Ice</strong> Deflector Kits Bin<br />

K00382 B750, B1050, B1100, B1400<br />

K00383 Two <strong>i1470C</strong> units side by side on B1400<br />

K00385 B970<br />

K00386 C730<br />

Note: <strong>i1470C</strong> is not approved for B570 bins<br />

MII-077<br />

11/11<br />

Continued on Next Page...


<strong>i1470C</strong>/iCVD1495 QuietQube Remote Air Cooled <strong>Ice</strong> <strong>Machine</strong>s<br />

Cycle Times<br />

Freeze Time + Harvest Time = Total Cycle Time<br />

Air Temp<br />

Entering<br />

Condenser<br />

°F °C<br />

-20 to 70<br />

-29 to 21<br />

Freeze Time (Minutes)<br />

Water Temp. °F °C<br />

50/10 70/21 90/32<br />

11.5-13.7 12.5-14.8 14.5-17.2<br />

90/32 13.0-15.4 14.0-16.6 16.3-19.3<br />

100/38 14.1-16.7 16.1-19.1 17.5-20.7<br />

110/43 15.0-17.8 17.3-20.4 18.7-22.1<br />

Cycle times and pressures vary with operating condition<br />

Harvest<br />

Time<br />

0.75-2.5<br />

24 Hour <strong>Ice</strong> Production<br />

Remote Air Cooled<br />

<strong>i1470C</strong>/iCVD1495 QuietQube Remote Air Cooled <strong>Ice</strong> <strong>Machine</strong>s<br />

Operating Pressures (psig)<br />

<strong>Manitowoc</strong> <strong>Ice</strong>, 2110 S. 26th St., P.O. Box 1720, <strong>Manitowoc</strong>, WI 54221-1720, Tel: 920-682-0161, www.manitowocice.com<br />

MII-079 11/11<br />

Air Temp<br />

Entering<br />

Water Temperature<br />

Condenser<br />

°F °C<br />

50/10 70/21 90/32<br />

-20 to 70<br />

-29 to 21<br />

1330 1235 1080<br />

90/32 1190 1115 970<br />

100/38 1110 980 910<br />

110/43 1045 920 855<br />

<strong>Ice</strong> slab weight of one harvest cycle = 12.0 lb. to 14.0 lb.<br />

6.0 to 7.0 lbs per evaporator<br />

5.44 kg to 6.35 kg (2.72 to 3.18 kg per evaporator)<br />

230/50/1 is approximately 12% lower than 230/60/1<br />

Air Temp Entering<br />

Freeze Cycle Harvest Cycle<br />

Condenser<br />

°F °C<br />

Discharge Pressure Suction Pressure Discharge Pressure Suction Pressure<br />

-20 to 70 / -29 to 21 250-235 60-36 140-165 70-95<br />

80 / 28 250-235 60-38 150-170 70-95<br />

90 / 32 275-240 60-38 160-180 85-95<br />

100 / 38 300-285 65-39 170-190 90-110<br />

110 / 43 350-300 70-40 180-200 95-115<br />

120 / 49 410-350 80-40 190-215 100-125<br />

130 / 54 435-380 85-40 195-225 105-130<br />

During low ambient conditions, it is normal for the head pressure control valve to hunt (fluctuate up and down) on iCVD condensing units. Hunting<br />

varies by model and ambient temperature, but generally settles out within the first 6 minutes of the freeze cycle.

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!