Derwent World Patents Index (DWPI) - EPI ... - Thomson Reuters
Derwent World Patents Index (DWPI) - EPI ... - Thomson Reuters Derwent World Patents Index (DWPI) - EPI ... - Thomson Reuters
1086 Subject Index intravenous anaesthesia systems S05-L02 intravenous fluid delivery S05-J01A iontophoresis S05-A04A IT systems S05-G02G laser, IR, UV surgery S05-B01 life support systems S05-G02B3 limb prosthesis S05-F03 measurement, electrical or + magnetic S05-D01D measuring and recording S05-D01 measuring bioelectric current S05-D01A medicine/drug storage S05-M03 monitor built into telephone S05-D01 W01-C01P8 monitoring internal devices S05-Y05 nerve stimulation S05-A04 nano/micro scale devices S05-Y02 nuclear radiation diagnosis S05-D02C operating theatre equipment S05-G02C ovulation and conception detection S05-D09 pacemakers and defibrillators S05-A01 pain threshold sensing S05-D01X patient beds S05-G02B1 patient monitoring S05-G02B2 patient positioning for therapy S05-A10 patient table for radiation diagnosis S05-D02E physical therapy S05-A05 portable monitoring equipment S05-G02B2B prosthesis S05-F psychotechnics S05-D01X pulse measurement S05-D01B5 pumping S05-H radiation diagnosis S05-D02 reflex measurement S05-D01F remote monitoring of patients S05-G02B2A respiration measurement S05-D01C1 respiratory assistance using gas S05-G02E respiratory massage S05-A05A sex determination S05-D09 simulation and education systems S05-P speech therapy S05-A09 sterilising S05-G01 stethoscope S05-D01H stimulable phosphor sheet S05-D02A5C surgery, laser, IR, UV S05-B01 surgery, mechanical and electrical S05-B03 surgery, ultrasonic S05-B02 teaching S05-X Telediagnosis S05-D06A temperature measurement S05-D01E testing of drugs S05-C05 testing and monitoring of medical apparatus S05-Y01 therapy or treatment S05-A tomography, X-ray S05-D02A1 transplanting S05-X treatment planning systems S05-G02G4 treatment using optical, UV, or IR radiation S05-A03A trolley for patients S05-G02A ultrasonic and sonic diagnosis S05-D03 ultrasonic medical equipment S05-D03B ultrasonic transducer arrangements S05-D03A2 ultrasonic transducer details S05-D03A1 wheelchair S05-G02A X-ray detector positioning S05-D02A6B X-ray diagnosis S05-D02A5 X-ray generation, for diagnosis S05-D02A3 X-ray recording, diagnostic images S05-D02A5 X-ray source positioning S05-D02A6A X-ray, protection from S05-D02A3 Medicine administration and management S05-M01 analysis S03-E14A1 S05-C05 computer systems T01-J06A dosing and storage S05-M gas delivery S05-M04 monitoring patient compliance S05-M02 Meeting co-ordination T01-N03A3 Membrane switch V03-C01A2A Memory address selection U14-A08A addressing circuitry U14-A08 analogue U14-B bistable FET cells - see RAMs, static, with bistable FET cells U14-A03B1 bit line control U14-A07 bubble, magnetic U14-A01A1 clock/synchronisation circuit U14-A07C combined FET and bipolar U14-A03B5 computer interface for T01-C01C data refreshing U14-A03B4A dynamic U13-C04B1A ferro-electric, computer interface for T01-C01C FET and capacitor - see RAMs, dynamic, with capacitor store U14-A03B4 fixed-program - see ROMs, fixed program U14-A06B flip-flop - see RAMs, static, with bistable FET cells U14-A03B1 initialisation circuitry U14-A07 interconnection layout U14-C01 manufacture U11-C18B5 mask-programmable - see ROMs, mask programmable U13-C04A U14-A06B5 multilevel U14-B01 multiport U14-A08B1 neutral models U14-B02 non-reprogrammable - see ROMs, non-reprogrammable U14-A06B non-reprogrammable, using diodes - see ROMs, non-reprogrammable, using diodes U13-C04A U14-A06B1 non-reprogrammable, using fuses - see ROMs, non-reprogrammable, using fuses U13-C04A U14-A06B1 non-volatile, ultraviolet erasable - see ROMs, ultraviolet erasable U13-C04A U14-A06C one-time programmable U14-A06B packages U14-A10 power supply U14-A09 precharge and equalisation circuitry U14-A07 programming/erasing U14-A07B reading/writing U14-A07 ROM, electrically programmable U13-C04A1 ROM/RAM combined U14-A03B9 sensing circuitry U14-A07A smart card T04-K01 software error prevention U14-A11
static RAM U13-C04B1B testing, using built-in circuits U14-D01 testing, using error correction codes U14-D02 thin film arrays U14-H01A thin magnetic film U14-A04A using bipolar transistors U14-A03A1 using diodes/bipolar transistors/thyristors U14-A03A with adjustable threshold FET cells U14-A03B7 with electro-optical element U14-A02A with electrochemical cell U14-A03X with ferroelectric elements U14-A03F with FETs U14-A03B with hologram storage U14-A02B1 with magneto-optical element U14-A02A with optical storage element U14-A02B with random access - see RAMs U14-A03 with redundant circuits U14-D01A U14-D01B with shift stores - see Shift stores U14-A01 with superconductive elements U14-A03G U14-F02B with variable resistance organic film U14-A03X word line control U14-A08 Memory bus access control T01-H05B1 Memory storage in facsimile S06-K07A4 Memory storage in telephone W01-C01Q2 Internal W01-C01Q2A External W01-C01Q2C T01-H01B3A Memory systems, computer T01-H01B associative T01-H03B by type T01-H03 cache T01-H03A content addressable T01-H03B dual port T01-H03D hardware details T01-H01A illegal access T01-H01C2 interleaved T01-H03C multiprocessor memory management T01-H08 non-volatile T01-H01B3D other memory components T01-H01X other memory types T01-H03X preventing memory corruption/loss T01-H01C4 protection of contents T01-H01C refresh T01-H01C3 sequential access T01-H03D shared T01-H03D smart card, fraud prevention T01-H01C1 stacks T01-H01D static T01-H01B3 storage components T01-H01B virtual T01-H03A MEMS U12-B03F1 MEMS actuator V06-M06G MEMS device U12-B03F1A MEMS display T04-H03C8 MEMS generator V06-M06G8 MEMS motor V06-M06G MEMS oscillator U23-A01A2 MEMS relay V03-D10 MEMS resonator V06-V01E V06-V01K1 MEMS sensor V06-V01K1 V06-V04G EPI Manual Codes 2011 1087 Part 3 MEMS switch V03-C10 MEMS switch, manufacture V03-C07A MEMS system U12-B03F1B MEMS transducer(audio) V06-V01K1 V06-V04A Menu-driven telephone W01-C01G8A Menu interface, keyboard T01-C02A1 Mercury selenide - see AII-BVI compounds Mercury sulphide - see AII-BVI compounds Mercury telluride - see AII-BVI compounds Mercury thermometer S03-B01D MESFET - see Field effect transistor U12-D02B Metadata T01-J05B2C Metadyne X11-H09 control X13-F03A9 X13-G01A Metal casting X25-A01 casting, control T06-D05B detector S03-C02B phase segregation, semiconductor masking U11-C04D2 refining, electrolysis X25-R02 shaping X25-A02 shaping, control T06-D05A working, control T06-D05A Metal base transistor - see Hot electron transistor U12-D02J Metal insulator-silicon oxide-silicon structures - see MIOS Metal vapour laser - see Lasers V08-A04B Metal-air hybrid cell X16-A01B X16-D01 electrode X16-E03 X16-E06C1 Metal-air primary cell X16-A01B Metal-air secondary cell X16-D01 Metal-halogen cell X16-B01D X16-D02 electrode X16-E06C2 Metal-hydrogen cell X16-B01A3 electrode X16-E05C Metal-in-gap magnetic head T03-A03F gap-filling material T03-A03F1 Metal-Insulator-Metal - see MIM Metallurgical connections, semiconductor devices U11-D03B bonding pads U11-D03B1 bump terminals U11-D03B1 fuse U12-C04 HF monolithic signal transmission lines U11-D03B9 metal-ceramics bonding U11-D03B3 solder U11-D03B3 to substrate U11-D03B3 Metallurgy X25-Q cold working X25-Q02 heat treatment X25-Q02 iron or steel manufacture X25-Q01 process X25-Q
- Page 95 and 96: End cap for insulating direct conne
- Page 97 and 98: Expert systems T01-J16A knowledge b
- Page 99 and 100: for imaging tubes V05-D07C5C for te
- Page 101 and 102: testing S02-C07 thermal - see also
- Page 103 and 104: Frequency selective network distrib
- Page 105 and 106: G Gain control U24-C amplitude-lock
- Page 107 and 108: Global Positioning System S02-B08C
- Page 109 and 110: Headphone V06-V04A4 circuits V06-V0
- Page 111 and 112: Home location register W01-B05A1Q W
- Page 113 and 114: I i-mode telephone W01-C01G6E IC -
- Page 115 and 116: Ice detection S03-D02B for aircraft
- Page 117 and 118: Imprint lithography, for semiconduc
- Page 119 and 120: transceiver W02-C04A4 transmitter W
- Page 121 and 122: Intelligent transducer V06-V01Q Int
- Page 123 and 124: Internet portal T01-N02B1H Internet
- Page 125 and 126: K Kalman filter U22-G01A1B Karaoke
- Page 127 and 128: connections, optical fibre U12-A01C
- Page 129 and 130: manufacture U11-C18B4 organic/ poly
- Page 131 and 132: portable, solar-powered X26-E01E po
- Page 133 and 134: well S03-C01C X25-E02 well, electro
- Page 135 and 136: variables measurement using SQUID S
- Page 137 and 138: alloy materials T03-A03 array type
- Page 139 and 140: electric installation X12-G01D elec
- Page 141 and 142: coefficient of friction, measuremen
- Page 143 and 144: depth using microwaves S02-A05C3, S
- Page 145: volume S02-C volume flow S02-C VSWR
- Page 149 and 150: II-VI element substrate (novel) V05
- Page 151 and 152: cellular base station W01-B05A1A W0
- Page 153 and 154: Multi-standard TV receiver decoder
- Page 155 and 156: Nd:YAG laser V08-A04C Near-field sy
- Page 157 and 158: Noise-measuring receiver S01-G08B3
- Page 159 and 160: hospital beds S05-G02B1 hospital mo
- Page 161 and 162: Optical disk carrier T03-B01 contai
- Page 163 and 164: card player/recorder T03-B10C T03-N
- Page 165 and 166: P P-n junction, IC component isolat
- Page 167 and 168: vehicle licence plate T04-D07C T07-
- Page 169 and 170: substrate, depositing (patterned) m
- Page 171 and 172: triggered by lack of activity W05-B
- Page 173 and 174: density S03-F01 emulsion concentrat
- Page 175 and 176: Polarimetry, optical S03-A02C Polar
- Page 177 and 178: micro hydroelectric X11-B05 mini hy
- Page 179 and 180: ushing X12-C01C bushing, manufactur
- Page 181 and 182: electroerosive S06-J electrographic
- Page 183 and 184: lens/optics associated with CRT V05
- Page 185 and 186: overvoltage limiter U24-F02 X13-C03
- Page 187 and 188: Q Q-factor measurement S01-D05A5 QA
- Page 189 and 190: audio amplifier W02-G03F baseband b
- Page 191 and 192: Rankine cycle plant X11-C05 Rapid p
- Page 193 and 194: duplication prevention, audio W04-G
- Page 195 and 196: components, frost sensor X27-F02C2
1086 Subject <strong>Index</strong><br />
intravenous anaesthesia systems S05-L02<br />
intravenous fluid delivery S05-J01A<br />
iontophoresis S05-A04A<br />
IT systems S05-G02G<br />
laser, IR, UV surgery S05-B01<br />
life support systems S05-G02B3<br />
limb prosthesis S05-F03<br />
measurement, electrical or + magnetic<br />
S05-D01D<br />
measuring and recording S05-D01<br />
measuring bioelectric current S05-D01A<br />
medicine/drug storage S05-M03<br />
monitor built into telephone S05-D01<br />
W01-C01P8<br />
monitoring internal devices S05-Y05<br />
nerve stimulation S05-A04<br />
nano/micro scale devices S05-Y02<br />
nuclear radiation diagnosis S05-D02C<br />
operating theatre equipment S05-G02C<br />
ovulation and conception detection S05-D09<br />
pacemakers and defibrillators S05-A01<br />
pain threshold sensing S05-D01X<br />
patient beds S05-G02B1<br />
patient monitoring S05-G02B2<br />
patient positioning for therapy S05-A10<br />
patient table for radiation diagnosis S05-D02E<br />
physical therapy S05-A05<br />
portable monitoring equipment S05-G02B2B<br />
prosthesis S05-F<br />
psychotechnics S05-D01X<br />
pulse measurement S05-D01B5<br />
pumping S05-H<br />
radiation diagnosis S05-D02<br />
reflex measurement S05-D01F<br />
remote monitoring of patients S05-G02B2A<br />
respiration measurement S05-D01C1<br />
respiratory assistance using gas S05-G02E<br />
respiratory massage S05-A05A<br />
sex determination S05-D09<br />
simulation and education systems S05-P<br />
speech therapy S05-A09<br />
sterilising S05-G01<br />
stethoscope S05-D01H<br />
stimulable phosphor sheet S05-D02A5C<br />
surgery, laser, IR, UV S05-B01<br />
surgery, mechanical and electrical S05-B03<br />
surgery, ultrasonic S05-B02<br />
teaching S05-X<br />
Telediagnosis S05-D06A<br />
temperature measurement S05-D01E<br />
testing of drugs S05-C05<br />
testing and monitoring of medical<br />
apparatus S05-Y01<br />
therapy or treatment S05-A<br />
tomography, X-ray S05-D02A1<br />
transplanting S05-X<br />
treatment planning systems S05-G02G4<br />
treatment using optical, UV, or IR radiation<br />
S05-A03A<br />
trolley for patients S05-G02A<br />
ultrasonic and sonic diagnosis S05-D03<br />
ultrasonic medical equipment S05-D03B<br />
ultrasonic transducer arrangements S05-D03A2<br />
ultrasonic transducer details S05-D03A1<br />
wheelchair S05-G02A<br />
X-ray detector positioning S05-D02A6B<br />
X-ray diagnosis S05-D02A5<br />
X-ray generation, for diagnosis S05-D02A3<br />
X-ray recording, diagnostic images S05-D02A5<br />
X-ray source positioning S05-D02A6A<br />
X-ray, protection from S05-D02A3<br />
Medicine<br />
administration and management S05-M01<br />
analysis S03-E14A1<br />
S05-C05<br />
computer systems T01-J06A<br />
dosing and storage S05-M<br />
gas delivery S05-M04<br />
monitoring patient compliance S05-M02<br />
Meeting co-ordination T01-N03A3<br />
Membrane switch V03-C01A2A<br />
Memory<br />
address selection U14-A08A<br />
addressing circuitry U14-A08<br />
analogue U14-B<br />
bistable FET cells - see RAMs, static,<br />
with bistable FET cells U14-A03B1<br />
bit line control U14-A07<br />
bubble, magnetic U14-A01A1<br />
clock/synchronisation circuit U14-A07C<br />
combined FET and bipolar U14-A03B5<br />
computer interface for T01-C01C<br />
data refreshing U14-A03B4A<br />
dynamic U13-C04B1A<br />
ferro-electric, computer interface for T01-C01C<br />
FET and capacitor - see RAMs,<br />
dynamic, with capacitor store U14-A03B4<br />
fixed-program - see ROMs, fixed<br />
program U14-A06B<br />
flip-flop - see RAMs, static, with<br />
bistable FET cells U14-A03B1<br />
initialisation circuitry U14-A07<br />
interconnection layout U14-C01<br />
manufacture U11-C18B5<br />
mask-programmable - see ROMs, mask<br />
programmable U13-C04A<br />
U14-A06B5<br />
multilevel U14-B01<br />
multiport U14-A08B1<br />
neutral models U14-B02<br />
non-reprogrammable - see ROMs,<br />
non-reprogrammable U14-A06B<br />
non-reprogrammable, using diodes - see<br />
ROMs, non-reprogrammable, using<br />
diodes U13-C04A<br />
U14-A06B1<br />
non-reprogrammable, using fuses - see<br />
ROMs, non-reprogrammable, using<br />
fuses U13-C04A<br />
U14-A06B1<br />
non-volatile, ultraviolet erasable - see<br />
ROMs, ultraviolet erasable U13-C04A<br />
U14-A06C<br />
one-time programmable U14-A06B<br />
packages U14-A10<br />
power supply U14-A09<br />
precharge and equalisation circuitry U14-A07<br />
programming/erasing U14-A07B<br />
reading/writing U14-A07<br />
ROM, electrically programmable U13-C04A1<br />
ROM/RAM combined U14-A03B9<br />
sensing circuitry U14-A07A<br />
smart card T04-K01<br />
software error prevention U14-A11