Achieve More Productivity with OPTIMASS - Krohne
Achieve More Productivity with OPTIMASS - Krohne Achieve More Productivity with OPTIMASS - Krohne
Coriolis Mass Flow Application Story – Wax Production in UK UK wax manufacturer Kerax Limited has installed an OPTIMASS 7300 mass flowmeter to improve the accuracy of production processes at its plant in Chorley, Lancashire. Application: Kerax produces a variety of different waxes to be used in making castings and as ingredients in products such as adhesives. Each formulation requires the blending of two or three types of wax plus a number of additives. The mechanical meter previously positioned on the input to the blending vessel was not able to provide the accuracy needed for Kerax’s increasingly stringent process control. Problem: The wax flowing through the meter can vary in density from 0.8 to 1.0 kg/litre and in viscosity from 5.5 cP to 1,200 cP. It can be flowing at rates varying from 1.8 to 15 tonnes / hour with pressures from 1.4 bar to more than 4.1 bar at temperatures ranging from 20 to 120°C. Solution: OPTIMASS 7300-T 50 The installed OPTIMASS 7300 Coriolis mass flowmeter is capable of handling the wide variation in process conditions whilst still delivering accuracy of +/- 0.1 per cent. STRAIGHT TALK To maintain a consistent product temperature, the OPTIMASS meter is fitted with a heating jacket that can be fed with hot water or steam. Copyright KROHNE, inc. , 2009 OPTIMASS Applications Page No.52
Application Story – Siemens Gasification Test Rig STRAIGHT TALK The Siemens gasification centre in Freiberg, Germany, is one of the most comprehensive gasification test facilities in the world. Its gasification reactor is rated at five MWth and can be adjusted to different feedstock conditions. The facility also includes a range of feedstock preparation systems and related gas cleaning process units. A test rig for large-scale, high-pressure feeding tests and further equipment for coal and slag analysis (e.g. fluidization and viscosity) complement the facilities. With this equipment, a broad range of test conditions can be simulated. For the examination of fouling in heat exchangers, a test rig was designed to gain experience when preheating process water up to 220°C. Thermo oil is used as a heating medium in the heat exchanger. Both the monitoring of temperature and a reliable monitoring of the volume flow are decisive factors for the evaluation. An OPTIMASS 9000 from KROHNE was installed to control the thermo oil volume flow. The mass flowmeter records the volume flow of the thermo oil at 230 °C and 10 barg. The maximal permissible temperature of the thermo oil is 300°C. Optimass 9000 S25 Medium: Heating oil Flow rate:2500 kg/h Temperature: 260°C Pressure:1-11 bar With thanks to Klaus Loetsch of KMT Freiburg for this application note Copyright KROHNE, inc. , 2009 OPTIMASS Applications Page No.53 1
- Page 1 and 2: Straight to the heart of the matter
- Page 3 and 4: Optimass Application Note Brewing B
- Page 5 and 6: Optimass Through local representati
- Page 7 and 8: Optimass Application Note Tequila i
- Page 9 and 10: Application Story Application STRAI
- Page 11 and 12: Coriolis Mass Flow Application Stor
- Page 13 and 14: Process Parameters Product: Salad D
- Page 15 and 16: Above: Our KROHNE Service Engineer
- Page 17 and 18: Application Story - Bio-Ethanol Pro
- Page 19 and 20: Biodiesel in Germany The photo at r
- Page 21 and 22: Application Story - Chemical Indust
- Page 23 and 24: Tanker loading using 6 OPTIMASS met
- Page 25 and 26: Application Story - Chemical Dosing
- Page 27 and 28: Application Story: Liquid Sulphur m
- Page 29 and 30: Application Story Akzo Nobel UK Wor
- Page 31 and 32: Application Story - Petrochemicals
- Page 33 and 34: Coriolis Mass Flow Application Stor
- Page 35 and 36: Optimas Sand Separation Application
- Page 37 and 38: The Adaptive Sensor Technology of O
- Page 39 and 40: Changing to KROHNE Coriolis meters.
- Page 41 and 42: Application Stories Density Measure
- Page 43 and 44: Application Story Enzyme Production
- Page 45 and 46: The Forgotten Meters? …. continue
- Page 47 and 48: Application Story - Carbon Black Pr
- Page 49 and 50: Application Story - 1 st Optimass 2
- Page 51: Application: Loading Station Why KR
- Page 55 and 56: Ovako Steel at Hofors Why Krohne No
- Page 57 and 58: Application Story Czech Republic Cu
- Page 59 and 60: Coriolis Mass Flow Applications - O
- Page 61 and 62: Coriolis Mass Flow The customer nee
- Page 63: Coriolis Mass Flow Installation 1:
Coriolis Mass Flow<br />
Application Story – Wax Production in UK<br />
UK wax manufacturer Kerax Limited has installed an<br />
<strong>OPTIMASS</strong> 7300 mass flowmeter to improve the<br />
accuracy of production processes at its plant in<br />
Chorley, Lancashire.<br />
Application:<br />
Kerax produces a variety of different waxes to be used in making castings and as<br />
ingredients in products such as adhesives. Each formulation requires the<br />
blending of two or three types of wax plus a number of additives. The mechanical<br />
meter previously positioned on the input to the blending vessel was not able to<br />
provide the accuracy needed for Kerax’s increasingly stringent process control.<br />
Problem:<br />
The wax flowing through the<br />
meter can vary in density from<br />
0.8 to 1.0 kg/litre and in<br />
viscosity from 5.5 cP to 1,200<br />
cP. It can be flowing at rates<br />
varying from 1.8 to 15 tonnes /<br />
hour <strong>with</strong> pressures from 1.4 bar<br />
to more than 4.1 bar at<br />
temperatures ranging from 20 to<br />
120°C.<br />
Solution: <strong>OPTIMASS</strong> 7300-T 50<br />
The installed <strong>OPTIMASS</strong> 7300<br />
Coriolis mass flowmeter is capable<br />
of handling the wide variation in<br />
process conditions whilst still<br />
delivering accuracy of +/- 0.1 per<br />
cent.<br />
STRAIGHT TALK<br />
To maintain a consistent product<br />
temperature, the <strong>OPTIMASS</strong> meter is<br />
fitted <strong>with</strong> a heating jacket that can be fed<br />
<strong>with</strong> hot water or steam.<br />
Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.52