09.01.2013 Views

Achieve More Productivity with OPTIMASS - Krohne

Achieve More Productivity with OPTIMASS - Krohne

Achieve More Productivity with OPTIMASS - Krohne

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Application Stories<br />

Density Measurement of Carbonate Slurry in the Paper Industry<br />

The measurement of the density of Carbonate slurry has<br />

evolved considerably in the last few years in the paper<br />

industry and in particular at this customer in Finland.<br />

Initially the density was measured using Radiometric<br />

density meters and, combined <strong>with</strong> an Electromagnetic<br />

flowmeter, the mass flow was calculated. Here Berthold<br />

density meters and KROHNE IFM5110F Magnetic<br />

Flowmeters were used.<br />

Later on this measurement method was discontinued due<br />

to the ‘percieved’ dangers of Radiometric measurement<br />

and Single Straight Tube Coriolis meters were used to<br />

replace this technology. The process involves and<br />

evaporation process where the slurry is continuously<br />

circulated till the correct density is achieved in the<br />

evaporator. The Carbonate slurry is then pumped to a<br />

storage tank. A KROHNE 300 G+ was used for this<br />

process. In the initial production and mixing of the slurry<br />

and 800G+ was used. Further enhancement of the<br />

process was made using the Multi I/O option in the mass<br />

meters. This provided the plant engineers <strong>with</strong> more<br />

data <strong>with</strong> respect to the process, apart from density, eg<br />

temperature, mass flow etc.<br />

Later orders of mass flowmeters from KROHNE had the<br />

Profibus PA option which gave the plant engineers more<br />

flexibility in the control and monitoring of the plant.<br />

New Evaporator<br />

When it was decided to install a new evaporator the<br />

natural progression was to use the new Optimass<br />

meters from KROHNE.<br />

This project was started in October 2002 and fully<br />

commissioned by May 2003. Here an Optimass<br />

MFM7051 T40 <strong>with</strong> Profibus PA was used.<br />

KROHNE Magnetic flowmeter Model IFM 5090<br />

WITH Profibus PA was used for water addition to<br />

the process.<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.41

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!