Application Story - PTFE production in England<br />

Asahi Glass Fluoropolymers UK Ltd installed four<br />

KROHNE <strong>OPTIMASS</strong> 7000 T10 flowmeters to<br />

measure heavy gas flow at its polytetrafluoroethylene<br />

(PTFE) manufacturing plant in Lancashire. Each<br />

<strong>OPTIMASS</strong> replaced 2 previous measuring devices for<br />

pressure and temperature.<br />

Tetrafluoroethylene (TFE) is a dense, almost liquid,<br />

heavy gas used in the production of PTFE.<br />

The TFE gas is produced in a separate area of the factory and pumped into the PTFE<br />

manufacturing plant through a common pipeline 24 hours per day. The common gas<br />

feed is then split into four lines to produce different grades of PTFE, each of which is<br />

fitted <strong>with</strong> an <strong>OPTIMASS</strong> flowmeter.<br />

TFE gas pipeline<br />

STRAIGHT TALK<br />

Water removal process<br />

1000 kg/h<br />

PTFE Slurry<br />

Process Parameters<br />

Medium : Tetrafluoroethylene<br />

Flow Range : 0 ... 20 kg/min<br />

Density : 144.8 kg/m3<br />

Viscosity : 0.0135 cP<br />

Temperature : 4 °C<br />

Pressure : 24 bar<br />

Polymerising<br />

Vessel<br />

Water and Initiator<br />

22 Bar<br />

The <strong>OPTIMASS</strong> T10 meters measure the TFE gas into a polymerising vessel<br />

<strong>with</strong> great accuracy. The gas is then combined <strong>with</strong> water and initiators in the<br />

reactor to produce the PTFE slurry which then has the water removed to leave<br />

the end product.<br />

Advantage for the customer:<br />

With the installation of these meters AGF improved the accuracy of gas<br />

measurement and eliminated the need for two measurement devices.<br />