09.01.2013 Views

Achieve More Productivity with OPTIMASS - Krohne

Achieve More Productivity with OPTIMASS - Krohne

Achieve More Productivity with OPTIMASS - Krohne

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Straight to the heart<br />

of the matter.<br />

7000 - high performance<br />

The road to productivity had many<br />

bends. Now, the straight tube<br />

innovations found only in the<br />

<strong>OPTIMASS</strong> Coriolis mass flow<br />

meters provide the shortest path.<br />

Processes around the world benefit<br />

from their high accuracy, tight repeatability,<br />

low pressure drop, wide<br />

flow range, and long-term reliability.<br />

Follow your heart. Let KROHNE<br />

<strong>OPTIMASS</strong> meters guide you straight<br />

to achieving more productivity.<br />

2000 - the latest & largest meter,<br />

to 12 inch<br />

1000 - general purpose<br />

confi dence<br />

security<br />

reliability<br />

effi ciency<br />

productivity<br />

value<br />

quality<br />

fl exibility<br />

control<br />

information<br />

accuracy<br />

<strong>Achieve</strong> <strong>More</strong>. Get Productive <strong>with</strong> <strong>OPTIMASS</strong>.<br />

Visit www.krohne.com/northamerica for the straight story on <strong>OPTIMASS</strong> meters and many other products<br />

in productivity improvement applications, or call your local sales representative for details.<br />

KROHNE, Inc., 7 Dearborn Road, Peabody, MA (USA) 01960<br />

1-800-356-9464 info@krohne.com<br />

www.krohne.com/northamerica


Optimass Application Story<br />

Application: Beer Brewing at Grolsch in Holland<br />

Observe the ice on the pipe above at right!<br />

<strong>OPTIMASS</strong> is capable of high<br />

measurement accuracy of 0.1 % for<br />

fluids and 0.5% for gasses. Our<br />

mass flow meters can measure<br />

density and volume flow as well as<br />

calculating Brix or Plato <strong>with</strong> the<br />

concentration option.<br />

Grolsch’s tests actually showed<br />

better than 0.1% accuracy when<br />

dosing 8 kg batches of hops<br />

When Grolsch built their new state of the art<br />

brewery at Enschede, they equipped it <strong>with</strong><br />

KROHNE flowmeters, including <strong>OPTIMASS</strong><br />

meters for the more demanding applications<br />

where there is high viscosity or no<br />

conductivity.<br />

In the brewery applications this includes<br />

dosing liquid sugar and hops and for<br />

measuring carbon dioxide levels in the cold<br />

recovery system.<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.2


Optimass<br />

Application Note<br />

Brewing Beer <strong>with</strong> KROHNE - Optimass<br />

DECKER – Hop Extract Processing Plant<br />

Customer: Decker Maschinenbau, 93358 Train<br />

For a big Brewing Plant in Holland<br />

Application<br />

In the brewing process, the hops are roasted in the pan. There are many different ways of doing this.<br />

So, too, <strong>with</strong> Hop extract processing.<br />

The Optimass T10 measures exact dosing of the Hop extract into a heating chamber at 45°C in<br />

order to keep the amount used to the minimum required.This means the optimum cost control <strong>with</strong><br />

Optimass.<br />

To ensure a clear operation and supervision, a galvanically separated output <strong>with</strong> PROFIBUS © PA is<br />

deployed.<br />

Process Parameters:<br />

Product : Hop extract<br />

Flow Rate : 6 kg/min<br />

Viscosity : 20 Pa s<br />

Density : 1035 kg/m³<br />

Temperature : 46 °C<br />

Pressure drop : 2,9 bar<br />

Meter type : <strong>OPTIMASS</strong> 10T<br />

R. Schiller KROHNE Munich<br />

28 May 2003<br />

INDUSTRY: FOOD AND BEVERAGE<br />

COUNTRY: GERMANY<br />

METER: <strong>OPTIMASS</strong> T10<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.3


Optimass<br />

Why use Optimass?<br />

Application Note<br />

Due to the very high viscosity and the subsequent need to reduce the pressure drop, it is necessary<br />

to choose a meter whose operating point lies in the lower range of the flow rate.<br />

In this case Optimass shows a marked improvement over the competition.<br />

Zero Stability<br />

Various doses were checked against a certified scale. The following diagram shows how impressive<br />

the performance of the new Optimass was. The low flow cutoff was switched off during the tests.<br />

- kg -<br />

8040<br />

8020<br />

8000<br />

7980<br />

7960<br />

Filling 8kg<br />

Trial 1 Trial 2 Trial 3 Trial 4 Trial 5<br />

<strong>OPTIMASS</strong> (kg) 8008 8018 7988 7987 8014<br />

Scales (kg) 8010 8020 7990 7990 8010<br />

deviation % -0.02 -0.02 -0.03 -0.04 0.05<br />

average % -0.01 -0.01 -0.01 -0.01 -0.01<br />

The client is delighted <strong>with</strong> the results of the measurement tests and the plant has now been delivered to the<br />

enduser to be brought into operation.<br />

R. Schiller KROHNE Munich<br />

28 May 2003<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.4<br />

0.06<br />

0.04<br />

0.02<br />

0.00<br />

-0.02<br />

-0.04<br />

-0.06<br />

- % -


Optimass<br />

Through local representative Control<br />

Engineering S.A., KROHNE beat E+H, ABB<br />

and Siemens (Danfoss) <strong>with</strong> the best<br />

technology; the lowest pressure drop on<br />

process and a reasonable price.<br />

But what really impressed LEONA was the<br />

wide flow range Optimass could handle,<br />

because production will be doubled over the<br />

next 5 years, and our meters could make the<br />

transition.<br />

Application Note<br />

INDUSTRY: BEVERAGE<br />

COUNTRY: COLOMBIA<br />

METER: <strong>OPTIMASS</strong> 80S<br />

CERVECERÍA BAVARIA S.A. is a beer<br />

monopoly in Colombia which ranks<br />

number 10 of the largest breweries world<br />

wide. They have seven plants in<br />

Colombia, dominate the beer market in<br />

Ecuador and Panama, and produce more<br />

than 60% of beer consumed in Peru.<br />

Among their plants in Colombia, they<br />

have CERVECERÍA LEONA, one of the<br />

more modern plants in South America,<br />

built in 1994.<br />

Because BAVARIA is focused on<br />

increasing efficiency, they want to<br />

measure several points of the process to<br />

detect process loss.<br />

So at LEONA they instigated a pilot trial<br />

using mass flow meters for wort in<br />

kitchens<br />

as well as for bright beer after filtration.<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.5


Application: Beer<br />

Process Parameters<br />

Bright beer after filters, Qty: 2<br />

Flow rate: 1000 Hl/h<br />

Flow rate projected: 1500 Hl/hr<br />

Temperature: 0 °C<br />

Pressure: 2.4 bar<br />

Density: 1.00 … 1.07 kg/l<br />

Viscosity: 1.00 … 1.70 CP<br />

Wort after heat exchangers, Qty: 2<br />

Flow rate: 800 Hl/h<br />

Flow rate projected: 1200 Hl/hr<br />

Temperature: 12 °C<br />

Pressure: 6 bar<br />

Density: 1.044 … 1.063 kg/l<br />

Viscosity: 1.50 … 1.74 CP<br />

Why KROHNE?<br />

Straight tube <strong>with</strong> lower pressure drops<br />

No effects on accuracy from pipe vibration<br />

Lower installation requirements<br />

A wide measuring range<br />

2<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.6


Optimass<br />

Application Note<br />

Tequila is the most popular drink in Mexico, and also a significant business for<br />

the producers, not only on the Mexican market but also internationally. The<br />

State of Jalisco is the only State in Mexico permitted to sow Agave and produce<br />

Tequila. Jalisco has many Tequila producers and one of the largest in sales is<br />

the Jose Cuervo brand. Jose Cuervo also exports Tequila by the 20-ton<br />

truckload. They have a filling station where they load the product into the trucks.<br />

Why KROHNE?<br />

Problem: Fiscal standards of accuracy for sales of alcohol<br />

Solution: Installation of reliable Optimass mass flow meters to ensure the<br />

accuracy of the invoiced quantity.<br />

Installation No.1: Suspended by two metal rods and two<br />

metal belts in a horizontal position from the top of the filling<br />

station.<br />

Optimass Type: S40<br />

Tri-clamp connections,<br />

120 VAC power supply<br />

Pulse output to a batch controller<br />

INDUSTRY: FOOD & BEVERAGE<br />

COUNTRY: MEXICO<br />

METER: <strong>OPTIMASS</strong> S40<br />

Process Conditions:<br />

Product: Tequila (alcohol)<br />

Pipeline: 2” Stainless Steel<br />

Temperature: 25 °C<br />

Pressure: 4 kg/cm2<br />

Density: 0.95<br />

Flow rate: 640 LPM<br />

Note:<br />

The meters have been<br />

installed in such a way that<br />

they will always be full.<br />

This is good engineering<br />

practice for this type of<br />

application.<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.7


Application: Fiscal loading of Tequila<br />

Optimass Type: S40<br />

Tri-clamp connections<br />

120 VAC power supply,<br />

Pulse output to a batch controller<br />

2<br />

Installation No. 2:<br />

In a horizontal pipeline<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.8


Application Story<br />

Application<br />

STRAIGHT TALK<br />

Brix Measurement for Fruit Canning in the US<br />

Signature Fruit, based in Modesto, California,<br />

is the leading producer of long-life fruit<br />

products. Its product range includes peach,<br />

pear, apricot and other juices. Signature Fruit<br />

markets its products under the brand names<br />

Libby's® and Nature´s Orchard TM, as well<br />

as under customers' own labels for<br />

international and industrial food retail. The<br />

mass flowmeters are used during the initial<br />

mixing of the bulk syrup, which consists of<br />

canners corn syrup, high fructose, and<br />

sucrose concentrates to achieve the desired<br />

Brix in the concentrate, which is calculated<br />

by the control system’s PLC. In the second<br />

stage the syrup mix is diluted <strong>with</strong> water and<br />

poured into containers <strong>with</strong> the fruit.<br />

Solution<br />

Why did the client choose KROHNE?<br />

Problem<br />

Exceptional concentration<br />

measurement and avoidance<br />

of large pressure drops over a<br />

wide flow range<br />

• Single straight tube give low pressure drop enabling reduction in size of meters<br />

ordered and resistance to blocking<br />

• Good flow range and turndown enabled reduction in number of meters ordered<br />

• Hygienic connectors available<br />

• Excellent concentration measurement of Brix<br />

Our thanks to Gordon Nickison of KROHNE Inc for this application<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.9<br />

1


Chocolate consumption measurement<br />

Customer<br />

Pauly Biskuit, Dessau, Germany<br />

Application<br />

Pauly Biscuits is producing Long Life bakery products<br />

on seven permanent baking lines and waffles on<br />

another seven production lines.<br />

In the coating section biscuit bars are double coated<br />

<strong>with</strong> chocolate. In order to measure the chocolate<br />

consumption and maintain a constant coating<br />

thickness two <strong>OPTIMASS</strong> T15 <strong>with</strong> heating jackets<br />

are installed, one at the dispensing point and one at<br />

the return flow.<br />

Process Parameters:<br />

Product : Chocolate coating<br />

Mass Flow : 1000 and 4000 kg/h<br />

Temperature : 45°C<br />

Viscosity : 1000 mPas<br />

Meter : MFS7000 – T15 <strong>with</strong> heating<br />

jacket<br />

Problem<br />

Accurate consumption measurement<br />

Solution<br />

Why did the client choose KROHNE?<br />

• Precise Meter<br />

• Hygienic version<br />

• Excellent References<br />

Application 31, <strong>OPTIMASS</strong><br />

One of the Pauly Biscuit production lines<br />

info@krohne.de www.krohne. 1/1<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.10<br />

Applikationen


Coriolis Mass Flow<br />

Application Story – loading of milk in France<br />

Cheese Producers sometime have to sell excess milk or buy in from other suppliers<br />

according to their production demands and quotas. They have various options<br />

available to measure this.<br />

Application :<br />

To accurately record the<br />

quantity of milk loaded<br />

into the tanker trucks<br />

from the storage areas of<br />

the factory. As the milk is<br />

pushed through the pipes<br />

by water, density<br />

measurement is used to<br />

determine the cut-off<br />

point so only milk goes<br />

into the tankers.<br />

Why did the customer choose KROHNE:<br />

The KROHNE sales team in France were able to use<br />

their experience to help the customer to choose Coriolis<br />

mass flowmeters instead of the weighbridge option, and<br />

to demonstrate to his customers that this was a reliable<br />

billing solution, <strong>with</strong>out having to resort to custody<br />

transfer transactions.<br />

Model chosen:<br />

The <strong>OPTIMASS</strong> 7000 has the technology. With its<br />

single straight tube, it is totally cleanable inline and<br />

approved for hygienic applications. The density<br />

measurement is used to limit the range of density<br />

between 1025 Kg/m3 and 1040 Kg/m3, allowing<br />

differentiation between the passage of the milk and<br />

the water.<br />

STRAIGHT TALK<br />

Benefits to the customer:<br />

Simple daily operation; reduced investment<br />

cost <strong>with</strong> the meter installed online in the<br />

loading pipes, avoiding the need for civil<br />

engineering works to build a weighbridge.<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.11


Optimass<br />

Customer<br />

Unilever Bestfood Schweiz, Thayingen, Switzerland<br />

Application Note<br />

Application<br />

Unilever Best Foods, known as one of the world’s largest producer of food<br />

products, have automated their production line in Thayingen. 10-liter pouches of<br />

gourmet salad dressing for restaurants are filled automatically. The plant is<br />

designed as a double filling station, enabling two flowmeters to batch two<br />

different products into the same pouch, either simultaneously or sequentially,<br />

depending on the type of dressing. Each pouch can be filled <strong>with</strong>in 7 seconds.<br />

For precise dosing the low flow cut off was taken out completely.<br />

Problem:<br />

Accurate batching of high viscosity salad<br />

dressing at low flow rates<br />

Why KROHNE?<br />

Solution:<br />

INDUSTRY: FOOD<br />

COUNTRY: SWITZERLAND<br />

METER: <strong>OPTIMASS</strong> T 15<br />

• High repeatability and accuracy<br />

• DIN 11864-2 All welded design <strong>with</strong><br />

EHEDG approval suitable for<br />

hygienic applications<br />

• Lack of installation restrictions<br />

• Self draining straight tube<br />

• Good experience <strong>with</strong> KROHNE<br />

PDF created <strong>with</strong> pdfFactory trial version www.software-partners.co.uk<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.12


Process Parameters<br />

Product: Salad Dressing<br />

Mass Flow: 1.2 kg/sec<br />

Nominal Pressure: 4 bar<br />

Density: 1.05<br />

Viscosity: up to 100 cPs<br />

Salad Dressing CH<br />

2<br />

Left: On the production line, each<br />

Optimass meter is simply attached to the<br />

framework by means of clamps fastened<br />

around the meter body, something that<br />

would have been impossible <strong>with</strong> most<br />

previous designs of Coriolis mass<br />

flowmeters. Such an installation would<br />

have had a detrimental affect on the<br />

performance of the meter.<br />

This is now possible <strong>with</strong> the 7000 Series<br />

due to KROHNE’s patented<br />

‘Adaptive Sensor Technology’ which<br />

intelligently ‘tunes’ each meter,<br />

independent of external forces and fluid<br />

density, to produce an inherently balanced<br />

instrument that remains stable in the most<br />

demanding processes.<br />

The finished product<br />

PDF created <strong>with</strong> pdfFactory trial version www.software-partners.co.uk<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.13


Optimass<br />

Application Note<br />

One of the UK’s leading speciality vegetable oil refineries is relying on the<br />

installation simplicity and accuracy of KROHNE’s revolutionary <strong>OPTIMASS</strong><br />

Coriolis mass flowmeters to monitor the flow of their products into road tankers.<br />

Above The <strong>OPTIMASS</strong> meters installed directly<br />

in a two metre high inverted u-bend to ensure<br />

there are no vapour inclusions<br />

<strong>with</strong>in the meter during operation<br />

Application<br />

INDUSTRY: FOOD<br />

COUNTRY: UK<br />

METER: <strong>OPTIMASS</strong> T50<br />

Vegetable oils <strong>with</strong> a variable loading<br />

temperature and a viscosity of<br />

between 8cp and 100cp, are pumped<br />

from storage tanks at an average<br />

mass flowrate of 60 tonnes per hour<br />

using centrifugal pumps. They are<br />

routed through two separate pipework<br />

systems, and pass through the<br />

flowmeters before reaching the loading<br />

points. The <strong>OPTIMASS</strong> meters send<br />

a pulse output to a batch controller to<br />

measure the mass of oil being<br />

pumped; when the totalised mass flow<br />

reaches a predetermined level the<br />

batch counter stops the pumps.<br />

Why KROHNE? The refinery has built up a close relationship <strong>with</strong> KROHNE<br />

over the past decade after the flow and level company solved installation<br />

problems experienced <strong>with</strong> flowmeters.<br />

Problem: Installation restrictions and achieving batch process accuracy <strong>with</strong><br />

Coriolis meters<br />

Solution: The innovative design of the 7000 Series, incorporating KROHNE’s<br />

‘Adaptive Sensor Technology’ ensures total flexibility of installation plus<br />

superb accuracy and repeatability.<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.14


Above: Our KROHNE Service Engineer<br />

checking the accuracy of reading after a<br />

tanker has been loaded <strong>with</strong> hard oil<br />

Customer Information<br />

2<br />

Process Parameters<br />

Product: Vegetable oils<br />

Mass Flow: 60 tonnes/hour<br />

Temperature: 20°C to 80°C<br />

Density: between 850 kg/M3 and<br />

950 kg/m3<br />

Viscosity: between 8 cp and<br />

100 cp<br />

Karlshamns are a Swedish vegetable oil refinery <strong>with</strong> the UK offices and<br />

refinery in Hull East Yorkshire. They are one of the largest suppliers of<br />

Vegetable oils in the UK, supplying both soft and hard oils such as Rapeseed<br />

oil, Coconut oil etc.<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.15


Optimass<br />

Application Note<br />

This customer, Tovarna Sladkorja Ormoz, is a sugar producer in Slovenia.<br />

They use lime milk as a flocculent and require the concentration of lime milk to be<br />

constant. In order to achieve this they purchased an Optimass T 50 <strong>with</strong> the<br />

Baumé concentration option.<br />

Due to the abrasive nature of lime milk, transition pieces were installed. As the<br />

Optimass T 50 meter is measuring at the upper velocity limit (6 m/s) for abrasive<br />

applications, after three months' operation the KROHNE agents in Slovenia made a<br />

resistance check and removed the instrument to see if any damage on the transition<br />

piece or instrument had occurred. <strong>More</strong> than 47,000 tons of lime milk had passed<br />

through the instrument but there was no trace of wear, either on the transition piece<br />

or on the instrument.<br />

The customer was very satisfied <strong>with</strong> the measurement.<br />

Why KROHNE?<br />

INDUSTRY: FOOD<br />

COUNTRY: SLOVENIA<br />

METER: T 50<br />

Process Parameters<br />

Product: lime milk<br />

(Suspension of calcium<br />

hydroxide in water)<br />

Mass Flow: 0 - 50 T/h<br />

Flow direction: from down to up<br />

Temperature: up to 80°C<br />

Nominal Pressure: 6 barg<br />

Density: 1070 - 1200 kg/m3<br />

Note the use of<br />

transition piece<br />

to protect the<br />

meter from<br />

abrasive<br />

process fluids<br />

Problem: Accurate control of concentration and resistance to abrasion<br />

Solution: The Optimass Titanium meter <strong>with</strong> its accurate concentration<br />

measurement.<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.16


Application Story – Bio-Ethanol Production in US & Canada<br />

Fuel Ethanol (200 Proof) is a renewable, clean<br />

burning & high octane fuel that is better for the<br />

environment than gasoline. It is also biodegradable<br />

and far less toxic than fossil fuels<br />

and can be used on its own (E100) or blended<br />

<strong>with</strong> gasoline (E10, E85 etc).<br />

Ethanol can be produced from starch/sugar rich<br />

feed stocks such as grains/cereals (corn, wheat,<br />

rice etc) , potatoes, cassava, beet/sugar cane and<br />

today even from cellulosic biomass sources viz.<br />

wood chips, switch grass, corn stover's, municipal<br />

waste, recycled paper etc.<br />

Of all these feed sources the Dry Grind/Milling<br />

process used for corn (or wheat) feed is the most<br />

popular in US & Canada. Typical <strong>OPTIMASS</strong><br />

applications on a Dry Grind/Milling process<br />

(shown on right) include density measurement for<br />

slurry tanks , liquefaction mash, syrup draw ,<br />

rectified & final proof measurements.<br />

Slurry #1 Density ( Slurry Preparation)<br />

Combined Flow/Density measurement using<br />

our <strong>OPTIMASS</strong> 7000 series (S50 straight<br />

tube) on the evaporator syrup draw<br />

application (shown below) provides a high<br />

investment return by improving the overall<br />

dryer process efficiency downstream of the<br />

evaporators.<br />

Evaporator Syrup Draw<br />

STRAIGHT TALK<br />

<strong>Krohne</strong> Inc has over 60+ installation ( and 50 more on order) of<br />

<strong>OPTIMASS</strong> 7000 series (S25/S50 tubes) on the corn<br />

slurry/mash & syrup applications . Additionally on each of these<br />

plants our 7000 series (S15 tubes) are installed on liquid<br />

ammonia feed lines that feed nutrients into the slurry tanks and<br />

fermentors.<br />

Liquefaction Mash<br />

(feed preparation for fermentors)<br />

Corn Slurry and syrup drawn from evaporators<br />

can be extremely nasty & viscous and will clog<br />

almost any bent tube designs - it is here that<br />

the single straight tube Optimass offers<br />

significant benefits.<br />

Also lower pressure drop is a desirable feature<br />

as energy optimization is of utmost importance<br />

on these high energy intensive processes. It<br />

are for these reasons that <strong>Krohne</strong> is able to<br />

demonstrate value over our competitors.<br />

Ammonia Flow<br />

Our thanks to Hemant Narayan, Industry Specialist - Energy & Biofuels at KROHNE America Inc<br />

For additional details contact narayan@krohne.com<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.17<br />

1


Production of Biodiesel<br />

optimass@krohne.co.uk<br />

Application<br />

<strong>OPTIMASS</strong> 7000 T40<br />

Custody Transfer<br />

Customer<br />

GHP Biodiesel at Oranienburg near Berlin. The Oranienburg Transesterification plant,<br />

one of 4 they operate in Germany, was established in 2001.<br />

Application<br />

Transesterification of animal fats and used<br />

oils is done by the classical alkali – process<br />

<strong>with</strong> KOH as catalyst. It is dissolved in<br />

Methanol to form an approx. 12,5 % solution,<br />

which is added to the plant oil. Separation of<br />

Glycerin – phase and Methyl-Esters is done<br />

by gravity.<br />

The installation was tested against the<br />

custody transfer calibration verification<br />

equipment and the mass flow accuracy was<br />

0,1 %. Volume flow also showed accuracy of<br />

better than 0,3 %.<br />

Process Parameters:<br />

Product : Organic oils and fats<br />

Mass Flow : 33000 kg/h and 16000 kg/h <strong>with</strong><br />

batching of 2000 l<br />

Temperature : 31 °C<br />

Density : 0,872 kg/l<br />

Pressure : 6 bar<br />

Problem Accurate measurement and batching to Custody Transfer standards<br />

Solution<br />

Why did the client choose KROHNE?<br />

• High accuracy and repeatability<br />

• Cost savings due to accurate batching<br />

• Approved for Custody Transfer<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.18<br />

Application story


Biodiesel in Germany<br />

The photo at right shows one<br />

of 4 Optimass T 80 Custody<br />

Transfer meters installed in the<br />

Tanker loading station at<br />

Biowerk Sohland in the<br />

Lausitz area of Germany. This<br />

is where the Biodiesel<br />

produced in the factory is<br />

loaded from the storage tanks<br />

into the distribution vehicles.<br />

Following the establishment of Biowerk<br />

Sohland in 2002, another company,<br />

PPM Energie Germany GmbH, was<br />

established to build biodiesel plants like<br />

the existing installation for national and<br />

international customers <strong>with</strong> capacity<br />

between 8,000 and 50,000 t/a, <strong>with</strong><br />

larger plants envisaged.<br />

Plants equipped <strong>with</strong> Optimass are now<br />

in Australia and Austria and 3 are being<br />

built for Hungary. They have already<br />

provided 6 plants in Germany.<br />

Above and right: some more of the Optimass<br />

meters installed in the production facility<br />

STRAIGHT TALK<br />

The Biodiesel Production facility here has<br />

a capacity of 25,000 tons pa.<br />

This facility also has 12 Optimass DN 15<br />

and DN 25 installed. The oils used for<br />

transesterification include rape oil,<br />

sunflower oil, and used cooking oils<br />

amongst others. Raw glycerine is<br />

produced as a byproduct and this can be<br />

used by biogas production facilties. There<br />

are no other waste products and the<br />

methanol used for extraction is recovered<br />

and reused.<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.19<br />

1


Biodiesel in Germany<br />

The photo at right shows one<br />

of 4 Optimass T 80 Custody<br />

Transfer meters installed in the<br />

Tanker loading station at<br />

Biowerk Sohland in the<br />

Lausitz area of Germany. This<br />

is where the Biodiesel<br />

produced in the factory is<br />

loaded from the storage tanks<br />

into the distribution vehicles.<br />

Following the establishment of Biowerk<br />

Sohland in 2002, another company,<br />

PPM Energie Germany GmbH, was<br />

established to build biodiesel plants like<br />

the existing installation for national and<br />

international customers <strong>with</strong> capacity<br />

between 8,000 and 50,000 t/a, <strong>with</strong><br />

larger plants envisaged.<br />

Plants equipped <strong>with</strong> Optimass are now<br />

in Australia and Austria and 3 are being<br />

built for Hungary. They have already<br />

provided 6 plants in Germany.<br />

Above and right: some more of the Optimass<br />

meters installed in the production facility<br />

STRAIGHT TALK<br />

The Biodiesel Production facility here has<br />

a capacity of 25,000 tons pa.<br />

This facility also has 12 Optimass DN 15<br />

and DN 25 installed. The oils used for<br />

transesterification include rape oil,<br />

sunflower oil, and used cooking oils<br />

amongst others. Raw glycerine is<br />

produced as a byproduct and this can be<br />

used by biogas production facilties. There<br />

are no other waste products and the<br />

methanol used for extraction is recovered<br />

and reused.<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.20<br />

1


Application Story – Chemical Industry in Switzerland<br />

Our new Tantalum <strong>OPTIMASS</strong> 7300 A15 is now installed in a vitamin<br />

production facility at this multinational chemical, pharmaceutical and<br />

nutritional company in Switzerland.<br />

Application:<br />

The Optimass 7300 C – A15 DN 25 PN 40 doses an aggressive fluid<br />

into a distillation column, where a vitamin is produced. The high flow<br />

velocity prevents deposition of the process medium on the inside of<br />

the tube.<br />

Technical data:<br />

Measuring range: 0-7000<br />

Kg/h<br />

Density: 0.881 Kg/l<br />

Temperature: 78°C<br />

Pressure: 1.8 bar<br />

Why KROHNE:<br />

The only Straight Tube<br />

Tantalum meter on the<br />

market!<br />

With thanks to Marc Madacs of <strong>Krohne</strong> Switzerland for this application note.<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.21


Application Story<br />

Varnish Production at BASF Coatings AG<br />

BASF Coatings division develops, produces and markets a range of top quality innovative<br />

vehicle, car repair and industrial varnishes and coating materials for buildings and offers<br />

the corresponding coating processes. The Münster site is one of the biggest varnish plants<br />

in the world <strong>with</strong> a total area of 400,000 square meters.<br />

In order to operate the mobile paddle<br />

mixers used in the colour grinding process<br />

<strong>with</strong>out supervision over 36-48 hours BASF<br />

used a flowmeter to trigger a leakage<br />

alarm. This meter needed to fulfill high<br />

specifications in terms of accuracy. The<br />

properties of the media made things even<br />

more difficult. The raw materials for<br />

varnishes are high-viscosity media which<br />

are processed at a low flow rate. They<br />

have viscosities of 7000mPas and over,<br />

and are also shear thinning - their behavior<br />

changes <strong>with</strong> the flow rate. The DN 40<br />

flowmeters also have to cope <strong>with</strong> high<br />

pigment contents. BASF Coatings did not<br />

want to risk any further pressure loss<br />

otherwise they would have to increase the<br />

performance of the pump. BASF Coatings<br />

thus opted for the <strong>OPTIMASS</strong>, a mass<br />

flowmeter which is virtually made for this<br />

application thanks to its straight-tube<br />

design.<br />

The grinding system is designed for a flow rate of<br />

approx. 5000kg/h. Communication <strong>with</strong> the PLC takes<br />

place via the <strong>OPTIMASS</strong>'s 4…20mA signal output.<br />

Every 90 seconds the PLC saves a flow<br />

measurement and compares it <strong>with</strong> the subsequent<br />

values. If there is a difference of 360kg/h, the system<br />

is automatically shut down. At present, further tests<br />

are underway to halve the leakage value.<br />

Why<br />

KROHNE?<br />

• Less pressure loss<br />

• Less abrasion<br />

• Suitable even for large flow volumes<br />

• Wide measuring range<br />

• No risk of blockage<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.22


Tanker loading using 6 <strong>OPTIMASS</strong> meters<br />

T 40 EEx in conjunction <strong>with</strong> batch controller<br />

Batching Master 100i ” from IBS-Control<br />

Process data:<br />

Flow: 50 t/h<br />

Density: 0.850 kg/l<br />

Temperature: 18 °C.<br />

Viscosity 1 mPas<br />

Solvent loading stations in Germany<br />

Application Story<br />

DHC Solvent Chemie<br />

GmbH in Mülheim an der<br />

Ruhr is a subsidiary of Ruhr<br />

Oel GmbH, a joint venture<br />

of Deutsche BP and<br />

Petróleos de Venezuela<br />

S.A. It is one of Europe‘s<br />

leading manufacturers of<br />

solvents and other<br />

speciality products from<br />

crude oil.<br />

The distillation unit is used<br />

to fractionate refinery<br />

feedstock to produce<br />

special boiling point<br />

products, white spirits,<br />

solvent naphtha and rollingoils.<br />

Our thanks to Dieter Timmerman of KROHNE Meßtechnik LGE West-Mitte for this application<br />

(If you need information or advice on batch controllers, please contact Product Management)<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.23


Application Story – Chemical Industry in Switzerland<br />

This chemical company in the Basel<br />

region used to dose the component<br />

products of the mixture one after<br />

another using a weigh scale. With the<br />

purchase of 2 Optimass T25s, 2 T40s<br />

and 2 x T80s they have greatly<br />

improved their mixing process enabling<br />

simultaneous dosing to save time and<br />

improve accuracy.<br />

The Optimass Straight tube<br />

meters solved the problem<br />

of dosing highly viscous<br />

material <strong>with</strong> minimal<br />

pressure loss.<br />

The accurate process<br />

information received from<br />

the customer enabled exact<br />

sizing which in turn enabled<br />

KAG to guarantee an<br />

accuracy of less than 1%.<br />

STRAIGHT TALK<br />

Above: the installed Optimass T25s<br />

Left: one of the Optimass T80s<br />

<strong>with</strong> heating jacket<br />

Below: the mixing unit w.<br />

remote converters<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.24


Application Story - Chemical Dosing in Switzerland<br />

This Chemical Industry customer in the Basel area is using 11 <strong>OPTIMASS</strong><br />

7300F PROFIBUS PA meters for dosing various fluids in a mixing vessel.<br />

Previously the end products were consecutively dosed in the mixer using load<br />

cells. Now it is possible to dose multiple ingredients through a ring main into the<br />

mixer simultaneously.<br />

Each product component has its own mass flowmeter. The new process<br />

method saves time and eliminates unnecessary measuring errors.<br />

STRAIGHT TALK<br />

11 x <strong>OPTIMASS</strong> 7300 F in sizes S10, S15, T15, T25 and T40<br />

<strong>OPTIMASS</strong> 7000 <strong>with</strong> a single straight tube meter is ideal for dosing fluids<br />

<strong>with</strong> high viscosities.<br />

Thanks to the exact process data supplied by the customer, we were able to<br />

fine tune the sizing and guarantee accuracy.<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.25


Coriolis Mass Flow<br />

Application Story - Liquefied gas measurement in UK<br />

Specialist chemical manufacturer<br />

F2 Chemicals Ltd has installed<br />

KROHNE’s <strong>OPTIMASS</strong> 8000<br />

Coriolis mass flowmeter to<br />

improve the reliability of liquefied<br />

gas flow measurement at its plant<br />

in Lancashire.<br />

The liquefied gas is distilled into several fractions which are used as active<br />

ingredients in pharmaceutical products. It was essential that F2 Chemicals<br />

found a way to measure the flow of the liquid reliably to ensure the<br />

consistent, high quality of its products.<br />

The measurement technology F2 Chemicals previously used to measure<br />

the flow of liquefied perfluorobutane and acetone did not provide the<br />

reliability which was critical for F2’s process.<br />

Perfluorobutane and acetone are contained in 100 litre industrial cylinders and are<br />

charged into the distillation column and refluxed through the <strong>OPTIMASS</strong> Coriolis<br />

mass flowmeter at flow rates of between 40 and 200 kg/hour and at pressures of<br />

between 2 and 7 bar. The temperature of the liquefied gas varies between -5°C<br />

and +15°C. A 20 mA signal is taken from the <strong>OPTIMASS</strong> and fed into a DCS.<br />

The reading is manually monitored and the distillation<br />

process adjusted according to temperature.<br />

Measurement reliability improved significantly since the<br />

KROHNE <strong>OPTIMASS</strong> 8000 Coriolis mass flowmeter was installed.<br />

STRAIGHT TALK<br />

F2 Chemicals installed<br />

KROHNE’s <strong>OPTIMASS</strong> 8000<br />

Coriolis mass flowmeter<br />

because of its ability to<br />

measure liquefied gas<br />

reliably and accurately at low<br />

temperatures. Its twin “u”<br />

shaped measuring tubes<br />

provide excellent signal-tonoise<br />

ratio and measurement<br />

turndown. This was<br />

important considering the low<br />

pressures of the gas being<br />

measured.<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.26


Application Story: Liquid Sulphur measurement in Russia<br />

Ammofos AG at Cherepovets is one of<br />

the leading Russian manufactures of<br />

phosphate fertilisers, and part of the<br />

chemical conglomerate JSC Fosagro AG<br />

The focus of the company is the<br />

production of sulphuric acid. Raw<br />

materials used in production are sulphur<br />

and pyrite.<br />

<strong>OPTIMASS</strong> 7050 T25 mass flowmeters<br />

are used to measure the flow of molten<br />

sulphur <strong>with</strong> a temperature up to 145°C.<br />

Ammofos plant in Cherepovets<br />

Problem: The temperature has to be kept above 130°C to prevent the<br />

sulphur from hardening and crystallising, and other measurement systems<br />

encountered problems.<br />

Solution: The Optimass meter <strong>with</strong> its efficient heating jacket prevents the<br />

product solidifying. The great advantage of the single straight tube meter is<br />

its low pressure drop. The other advantage is that, if the product does<br />

solidify the straight tube is easy to clean out and restart the process.<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.27


News : Optimass Mass Flowmeters in Loading Systems<br />

News<br />

Featured Product<br />

Exhibitions<br />

Newsletter<br />

News Archive<br />

Download Area<br />

KROHNE Corporate<br />

KROHNE Avtomatika<br />

KROHNE CIS<br />

Russia, 109147 Moscow<br />

Marksistskaya str. 3<br />

Business centre "Planeta", of. 404<br />

KROHNE CIS<br />

Update October 2006<br />

Search<br />

keyword<br />

Newsletter<br />

e-mail address<br />

KROHNE CIS News Products Applications Service Downloads Company<br />

Optimass Mass Flowmeters in<br />

Loading Systems<br />

Mass flowmeters of the Optimass family from KROHNE through their<br />

unique performance specifications are extensively used in various<br />

industrial applications for operating measurements and batching.<br />

However, this is far from being the only<br />

application area of these mass<br />

flowmeters. Growing prices on many kinds<br />

of products lead many plants and<br />

companies to look for effective methods of<br />

online monitoring of fluid operating flows,<br />

as well as measuring the quantities of<br />

product delivered to the buyer in business<br />

dealings.<br />

back to previous page<br />

Zoom<br />

Our customer, a major chemical plant, found an effective solution for a<br />

difficult task of hydrostabilized pyrolysis condensate loading into fuel tank<br />

trucks by using a straight-tube mass flowmeter Optimass 7000 along <strong>with</strong><br />

the dedicated software.<br />

Flowmeter functionality, enabling<br />

simultaneous measurements of the actual<br />

product flow both in mass and volumetric<br />

units, its total mass, as well as density<br />

and temperature <strong>with</strong> all the obtained data<br />

displayed on the operator's panel, ensures<br />

that the product is delivered accurately,<br />

Zoom<br />

Page 1 of 1<br />

which makes the mass flowmeter indispensable in loading applications.<br />

http://www.krohne.ru/russia_en/news/data/news-Optimass-Mass-Flowmeters-in-Load... 02/10/2006<br />

PDF created Copyright <strong>with</strong> KROHNE, pdfFactory inc. , 2009 trial version www.software-partners.co.uk<strong>OPTIMASS</strong><br />

Applications Page No.28


Application Story Akzo Nobel UK<br />

World leading producer of paints and coatings, Akzo Nobel<br />

Decorative Coatings, has installed four KROHNE<br />

<strong>OPTIMASS</strong> Coriolis Mass flowmeters at its manufacturing<br />

plant in Darwen, Lancashire to help accurately control<br />

product consistency and minimise production costs.<br />

Accurately measuring the amount of chemicals added to Akzo Nobel’s Crown<br />

range of solvent-based paint products is essential to minimising costs and<br />

maintaining consistent product quality. The chemicals are contained in stainless<br />

steel storage vessels located 70 meters away from the production facility and are<br />

pumped at low pressure through the <strong>OPTIMASS</strong> flowmeters into mixing vessels<br />

where the paint is manufactured in batches.<br />

Signals from the instruments are fed into the production control system which<br />

controls the flow of the chemicals from the storage vessels to ensure that the<br />

correct amount is added.<br />

Previously Akzo Nobel measured the amount of chemical added to batches of<br />

paint using a load cell-based weighing system. However this did not provide<br />

sufficient measurement accuracy for the range of batch sizes.<br />

The <strong>OPTIMASS</strong> 7000 Series, <strong>with</strong> its single straight measuring tube, features a<br />

patented AST design which offers outstanding accuracy and stability when used<br />

on low flow rate applications.<br />

By installing our <strong>OPTIMASS</strong> meters, Akzo Nobel has automated the process and<br />

significantly improved measurement accuracy.<br />

The installed meters are<br />

2 x <strong>OPTIMASS</strong> 7000 T25s measuring Calcium and Lithium,<br />

1 x 7000 T15 measuring Cobalt<br />

1 x 3000 S01 measuring silane monomer.<br />

STRAIGHT TALK<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.29


Optimass<br />

Process Parameters<br />

Product: Paint Waterbase and<br />

polyacrilate dispersals<br />

Mass Flow: 0.2 – 1.5 l/min<br />

Temperature: 18 – 27°C<br />

Nominal Pressure: 15 – 60 bar<br />

Application Note<br />

Linz Oberflachen Technik in Gablitz in Austria<br />

have installed 36 Optimass 3000 Series S04<br />

in their OEM equipment for paint and coatings<br />

mixing and dosing systems over the past 18<br />

months.<br />

Application: Mixing and Dosing Systems for<br />

paint and coatings for up to 6 components.<br />

Why KROHNE?<br />

INDUSTRY: PAINT MIXING OEM<br />

COUNTRY: AUSTRIA<br />

METER: 36 X <strong>OPTIMASS</strong> 3000 S04<br />

Problem: Accuracy and reliability required for<br />

low flows.<br />

Solution: The Optimass 3000 Series delivers<br />

the accuracy and reliability for trouble free<br />

running in the end user’s installation.<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.30


Application Story – Petrochemicals Manufacture in France<br />

Application:<br />

This major petrochemicals manufacturing site<br />

for polypropylene, polyethylene, styrene,<br />

polystyrene, butadiene, and aromatics<br />

introduced mass flow measurement to measure<br />

and record the input of highly viscous<br />

polybutadene styrene into the manufacturing<br />

process.<br />

This input was not previously measured.<br />

Process:<br />

Temperature: 30 ° C,<br />

Pressure: 8 bar,<br />

Density: 0.9 kg / l<br />

Viscosity: 7900 mPa.s<br />

Maximum flow rate: 13 T / H<br />

The <strong>OPTIMASS</strong> 7300 S80 was used <strong>with</strong> the converter installed in the control room<br />

directly connected to the digital process controller. With the MFC300 it is possible to<br />

have up to 300 meters between converter and sensor<br />

Benefits to the customer<br />

Improved process installation, and control<br />

of consumption of process materials.<br />

Less than 0.5 Bar pressure drop in spite of<br />

the additional equipment in the process<br />

line and the extreme viscosity of the<br />

process fluid.<br />

STRAIGHT TALK<br />

Why did the customer choose KROHNE?:<br />

A low pressure drop due to the single straight tube<br />

construction; quality advice on the setting up and<br />

installation of the sensor; assistance at the<br />

scheduled commissioning of the meter; and the<br />

bonus of an extended warranty for 2 additional<br />

years offered for the installation of this first device<br />

at this site.<br />

(Remember – you can always offer your customer a 3year<br />

guarantee in exchange for the process details <strong>with</strong><br />

the extended warranty card which they receive <strong>with</strong> the<br />

meter or fill in on the KROHNE website.)<br />

With thanks to Samuel MONNIER of <strong>Krohne</strong> France for this application note.<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.31


Application Story - PTFE production in England<br />

Asahi Glass Fluoropolymers UK Ltd installed four<br />

KROHNE <strong>OPTIMASS</strong> 7000 T10 flowmeters to<br />

measure heavy gas flow at its polytetrafluoroethylene<br />

(PTFE) manufacturing plant in Lancashire. Each<br />

<strong>OPTIMASS</strong> replaced 2 previous measuring devices for<br />

pressure and temperature.<br />

Tetrafluoroethylene (TFE) is a dense, almost liquid,<br />

heavy gas used in the production of PTFE.<br />

The TFE gas is produced in a separate area of the factory and pumped into the PTFE<br />

manufacturing plant through a common pipeline 24 hours per day. The common gas<br />

feed is then split into four lines to produce different grades of PTFE, each of which is<br />

fitted <strong>with</strong> an <strong>OPTIMASS</strong> flowmeter.<br />

TFE gas pipeline<br />

STRAIGHT TALK<br />

Water removal process<br />

1000 kg/h<br />

PTFE Slurry<br />

Process Parameters<br />

Medium : Tetrafluoroethylene<br />

Flow Range : 0 ... 20 kg/min<br />

Density : 144.8 kg/m3<br />

Viscosity : 0.0135 cP<br />

Temperature : 4 °C<br />

Pressure : 24 bar<br />

Polymerising<br />

Vessel<br />

Water and Initiator<br />

22 Bar<br />

The <strong>OPTIMASS</strong> T10 meters measure the TFE gas into a polymerising vessel<br />

<strong>with</strong> great accuracy. The gas is then combined <strong>with</strong> water and initiators in the<br />

reactor to produce the PTFE slurry which then has the water removed to leave<br />

the end product.<br />

Advantage for the customer:<br />

With the installation of these meters AGF improved the accuracy of gas<br />

measurement and eliminated the need for two measurement devices.<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.32


Coriolis Mass Flow<br />

Application Story – Waste Management in Canada<br />

StS Waste Management in Ontario Canada produce equipment for the<br />

solidification and stabilization of liquid waste streams.<br />

They have the only technology on the market to transform used liquid drilling<br />

fluids into disposable, dumpable solids in minutes, eliminating the need for<br />

expensive liquid disposal fees.<br />

A PitDry reagent chemically fixates heavy metal bearing wastes, stabilizes<br />

hydrocarbons and other organic and inorganic material while minimizing total<br />

solids volume. The equipment to process this incorporates an <strong>OPTIMASS</strong> T50<br />

for batching and totalizing low flows of slurry.<br />

STRAIGHT TALK<br />

Two views of the<br />

StS equipment<br />

incorporating the<br />

<strong>OPTIMASS</strong> 7000<br />

T50<br />

The apparatus is easily transportable and enables environmentally sound treatment<br />

and disposal of spent drilling fluids<br />

Our thanks to Angelo Del Buono for this Application Story<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.33<br />

1


Application Story: Waste Disposal in France<br />

The business of this company is the destruction of industrial waste by incineration.<br />

They specialise in the decontamination of equipment contaminated <strong>with</strong> PCBs and<br />

the destruction of halogenated products (compounds containing fluorine, chlorine,<br />

bromine or iodine.<br />

Application :<br />

Regulating the flow of all types of<br />

substance to the head of the<br />

furnace, in accordance <strong>with</strong> the<br />

corrosive nature of the fluids, which<br />

can also be mushy, crystallising, and<br />

containing large particles, all in a<br />

very hostile environment.<br />

Why the customer chose KROHNE:<br />

A complete range of meters to cover<br />

the needs of this type of industry, such<br />

as single straight tube, Hastelloy<br />

appliances for corrosion issues, high<br />

reliability and good technical support,<br />

both before and after sales for<br />

equipment choice and commissioning.<br />

STRAIGHT TALK<br />

Models Selected:<br />

<strong>OPTIMASS</strong> 7050 and 7300 H15: for its<br />

low pressure drop <strong>with</strong> viscous liquids.<br />

The single straight tube <strong>with</strong> constant<br />

diameter enables large particles to pass<br />

<strong>with</strong>out clogging and the Hastelloy tube<br />

handles the corrosion issues for a wide<br />

range of substances.<br />

<strong>OPTIMASS</strong> 8050 H25 high temperature<br />

meter: The heating jacket keeps the<br />

meter at a high temperature to avoid<br />

crystallization of the substances in the<br />

meter tube.<br />

Benefit for the customer:<br />

Low maintenance due to corrosion<br />

resistant materials, no clogging in the<br />

meter and reliable measurement.<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.34


Optimas<br />

Sand Separation<br />

Application Note<br />

INDUSTRY: MINING<br />

COUNTRY: SWEDEN<br />

METER: <strong>OPTIMASS</strong> T40<br />

Råda Sand AB is a producer and supplier of fine sand to various industries<br />

including concrete, filtration manufacturer etc. To be able to get the fine sand<br />

out of the water, they have to add the right amount of flocculent chemicals to<br />

settle the sand. The mass concentration controls the whole process in a ratio<br />

<strong>with</strong> the volume flow. We supplied the customer <strong>with</strong> an Optimass MFM7050<br />

T 40.<br />

Application: Flocculent<br />

Dosing<br />

Why KROHNE?<br />

Problem<br />

The customer required<br />

accurate dosing of the<br />

flocculent (inorganic<br />

coagulant) due to the high<br />

price of the flocculent and to<br />

improve efficiency.<br />

Solution<br />

The only equipment suitable<br />

for the customer was the<br />

Optimass due to its single<br />

straight tube, which is less<br />

susceptible to abrasion.<br />

The fluid is very abrasive due to its sand content (


Sand/Clay<br />

Slurry<br />

2<br />

Above: more views of the Optimass T40 in operation<br />

Flocculent<br />

Schematic Diagram of Operation<br />

Volumetric flow<br />

Gen.con<br />

Belt filter press<br />

2289<br />

DR21<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.36


The Adaptive Sensor Technology of<br />

Optimass removes the problem of external<br />

influences affecting measurement by using its<br />

own internal mass as a self compensating<br />

mechanism therefore responding quickly to<br />

changes in density.<br />

Application Story<br />

Salt Mining in Austria<br />

Shortly before its 25th Anniversary, Saline Austria in Ebensee<br />

modernised its installation in order to optimise production<br />

processes and minimise environmental impact.<br />

The brine tanks accumulate a slurry of chalk and<br />

gypsum at the bottom which has to be drawn off<br />

periodically. This led to a lot of the brine also<br />

being lost. However <strong>with</strong> the use of Optimass<br />

meters to measure the density, the valves can be<br />

closed as soon as pure brine is measured. The<br />

slurry density is around 1.3 kg/l and drops to 1.15<br />

<strong>with</strong> pure brine.<br />

Additionally a KROHNE Optimass is helping to improve the environmental impact as<br />

the waste water slurry from the process is no longer discharged into the Traunsee Lake<br />

but pumped back from Ebensee via a 20 km pipeline where it is forced into the salt<br />

caves of Bad Ischl which in turn displaces new brine. This is then returned by a<br />

separate pipeline. Here also, the KROHNE meter is being used for density control.<br />

Application: Salt production<br />

Why KROHNE?<br />

Problem:<br />

Loss of brine when slurry drawn off<br />

Solution:<br />

Prompt shut-off <strong>with</strong> Optimass density<br />

measurement<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.37


Optimass<br />

Application Note<br />

Paper Coating Plant produced by OEM customer, BVG<br />

for Paper Mill in Germany<br />

Application: Discontinuous Paper Coating<br />

Our customer BVG in Greifenberg is an important Original Equipment Manufacturer<br />

(OEM) for the paper industry operating world wide. The installation of this extremely<br />

compact discontinuous coating kitchen was made by BVG’s Dr. Bauer at a paper mill<br />

in Germany.<br />

BVG have also developed innovative continuous coating plants for other customers<br />

<strong>with</strong> on line coating and on line satinage using our Coriolis meters.<br />

Problem<br />

The problem for the end user lay in the recipe for the coating colour. There were<br />

always bonding problems between the background and the coating. This could have<br />

been caused because the required level of dosing accuracy was not achieved <strong>with</strong> the<br />

previously used positive displacement meters. Getting accurate and responsive<br />

measurements of the highly viscous and dense products batched such as clay, latex,<br />

carbonate and dispersants was difficult.<br />

Solution<br />

INDUSTRY: PULP AND PAPER<br />

COUNTRY: GERMANY<br />

METERS: 19 <strong>OPTIMASS</strong> T10, T15, T25, T40<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.38


Changing to KROHNE Coriolis meters. This installation contains a total of 19<br />

Optimass meters:<br />

- 4 X MFM 7050 T10<br />

- 4 X MFM 7050 T15<br />

- 5 X MFM 7050 T25<br />

- 6 X MFM 7050 T40<br />

2<br />

The Optimass meters are working very well. Some of these are connected in series,<br />

but there is absolutely no problem <strong>with</strong> this for Optimass, unlike earlier incarnations of<br />

Coriolis meters.<br />

Process Parameters<br />

Size Medium Flow rate Pressure Density Viscocity<br />

T40 Setacarb (Calcium 20,000 l/h 3 bar 1,7 kg/l 500 mPas<br />

carbonate, chalk),<br />

T40 Hydragloss (Kaolin) 20,000 l/h, 3 bar 1,85kg/l 500 mPas<br />

T40 Hydracarb (chalk) 20,000 l/h 3 bar 1,7 kg/l 500 mPas<br />

T 25 Latex 10,000 l/hr 3 bar 1.02 kg/l 0,150 mPas<br />

T40 Acronal<br />

10,000 l/h 3 bar 1,02 370 mPas<br />

(waterproofing)<br />

kg/l,<br />

T40 Emsol K115 10,000 l/h 3 bar 1.02 kg/l 1.000 mPas<br />

T40 Finnfix (Binder) 5,000 l/h 3 bar 1,02 kg/l 750 mPas<br />

T25 Acrosol 5,000 l/h 3 bar 1.08 kg/l 2000 mPas<br />

T25 Acrosol 1,000 l/h 3 bar 1.09 kg/l 2000 mPas<br />

T25 Poliviol (bonding,<br />

glue)<br />

1,000 l/h 3 bar 1.06 k/l 900 mPas<br />

T10 Blankophor (optical<br />

brightener<br />

1,000 l/h 3 bar 1.2 kg/l 50 mPas<br />

T10 NaOH 50% 1,000 l/h 3 bar 1.52 kg/l 0.0800 mPas<br />

T15 Elastofix<br />

(Waterproofing)<br />

2,000 l/h 3 bar 1.1 kg/l 45 mPas<br />

T25 ESTR200<br />

(defoamer)<br />

1,000 l/h 3 bar 0.86 kg/l 600 mPas<br />

T15 Polysalz (dispersant) 1.000 l/h 3 bar 1.26 kg/l 450 mPas<br />

T10<br />

X 2<br />

colour 500 l/h 3 bar 1.00 kg/l 0.020 mPas<br />

T15 Carrier Fluid 2,000 l/h 3 bar 1.40 kg/l 0.100 mPas<br />

T15 Spülmittel<br />

(flushing medium)<br />

2,000 l/h 3 bar 1.00 kg/l 0.500 mPas<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.39


KROHNE Service Engineer, Robert Klur, setting up the meters<br />

Our thanks to Peter Jüstel of KMT Süd for this application story<br />

3<br />

The view from behind<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.40


Application Stories<br />

Density Measurement of Carbonate Slurry in the Paper Industry<br />

The measurement of the density of Carbonate slurry has<br />

evolved considerably in the last few years in the paper<br />

industry and in particular at this customer in Finland.<br />

Initially the density was measured using Radiometric<br />

density meters and, combined <strong>with</strong> an Electromagnetic<br />

flowmeter, the mass flow was calculated. Here Berthold<br />

density meters and KROHNE IFM5110F Magnetic<br />

Flowmeters were used.<br />

Later on this measurement method was discontinued due<br />

to the ‘percieved’ dangers of Radiometric measurement<br />

and Single Straight Tube Coriolis meters were used to<br />

replace this technology. The process involves and<br />

evaporation process where the slurry is continuously<br />

circulated till the correct density is achieved in the<br />

evaporator. The Carbonate slurry is then pumped to a<br />

storage tank. A KROHNE 300 G+ was used for this<br />

process. In the initial production and mixing of the slurry<br />

and 800G+ was used. Further enhancement of the<br />

process was made using the Multi I/O option in the mass<br />

meters. This provided the plant engineers <strong>with</strong> more<br />

data <strong>with</strong> respect to the process, apart from density, eg<br />

temperature, mass flow etc.<br />

Later orders of mass flowmeters from KROHNE had the<br />

Profibus PA option which gave the plant engineers more<br />

flexibility in the control and monitoring of the plant.<br />

New Evaporator<br />

When it was decided to install a new evaporator the<br />

natural progression was to use the new Optimass<br />

meters from KROHNE.<br />

This project was started in October 2002 and fully<br />

commissioned by May 2003. Here an Optimass<br />

MFM7051 T40 <strong>with</strong> Profibus PA was used.<br />

KROHNE Magnetic flowmeter Model IFM 5090<br />

WITH Profibus PA was used for water addition to<br />

the process.<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.41


Optimass<br />

Application Note<br />

INDUSTRY: PHARMACEUTICAL<br />

COUNTRY: CZECH REPUBLIC<br />

METER: Optimass T10<br />

Sterile Water dosing application in the Pharmaceutical Industry<br />

MAAP s.r.o. is an OEM customer in the Czech Republic, manufacturing plant mainly<br />

for the Pharmaceutical Industry. The equipment below was produced for an end user<br />

in Austria.<br />

This is a sterile water batching application using flowmeter pulse output and a<br />

Siemens batch control system. The sterile water is then mixed <strong>with</strong> different<br />

additives, before filtration etc. and various pharmaceutical nutrient solutions are<br />

produced.<br />

Application: Sterile water dosing<br />

Why KROHNE?<br />

• Excellent performance/price ratio<br />

• Accurate dosing<br />

• Meets hygienic requirements<br />

• Suitable for Steam cleaning<br />

Process Parameters<br />

Product: Sterile Water<br />

Mass Flow: Batch sizes of 1<br />

to 10 litres<br />

Temperature:<br />

Operating temp 20°C <strong>with</strong><br />

steam cleaning up to 130°C<br />

Nominal Pressure: 0.7 mPa<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.42


Application Story<br />

Enzyme Production<br />

Process Conditions<br />

STRAIGHT TALK<br />

Applications in Denmark<br />

Temp. Density Viscosity Pressure<br />

20°<br />

1.036-1.037<br />

g/ml<br />

62 mPas 2,5 barg<br />

20° 1.300 g/ml 180 mPas 2,5 barg<br />

20° 1.258 g/ml 1410 mPAs 3 barg<br />

Waste Water Treatment<br />

The Optimass concentration<br />

measurement is used to measure<br />

solids before polymer dosing in a<br />

waste water treatment plant. The<br />

concentration of solids is<br />

approximately 5-7% and the<br />

waste water is both organic and<br />

non organic waste in the two<br />

lines.<br />

Temperature range is 12-19 °C<br />

and a pressure of app. 3 barg.<br />

This Pharmaceutical company in<br />

Denmark manufactures various<br />

enzymes used in the production of<br />

washing powder etc.<br />

The application pictured is the<br />

dosing of Sorbitol, Glycol and MPG<br />

into a continuous mixing of products<br />

for enzyme production.<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.43


Application Story<br />

Sterile Water dosing application in the Pharmaceutical Industry<br />

MAAP s.r.o. is an OEM customer in the Czech Republic, manufacturing plant mainly for the<br />

Pharmaceutical Industry. This equipment was produced for an end user in Austria.<br />

Optimass T10 meters are used for<br />

a sterile water batching application<br />

using flowmeter pulse output and a<br />

Siemens batch control system.<br />

The sterile water is then mixed <strong>with</strong><br />

different additives, before filtration<br />

etc. and various pharmaceutical<br />

nutrient solutions are produced.<br />

Batch sizes of 1 to 10 litres<br />

Operating temp 20°C <strong>with</strong> steam<br />

cleaning up to 130°C<br />

With thanks to Radmila Kompova of our KROHNE Ostrava office in the Czech Republic<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.44


The Forgotten Meters? …. continued<br />

The 9000 Series meter is suitable for all process temperatures above 230°C to<br />

350°C (392 to 572°F). This is a great meter where heating is also required.<br />

It is always supplied <strong>with</strong> an insulation jacket for safety reasons.<br />

We have had quite a bit of success on bitumen and carbon black applications<br />

(see PR at bottom of page).<br />

Please go out and sell a few of these meters. If you need help, please contact<br />

Product Management.<br />

If you are having price problems, let us know as well. We will try to help.<br />

Our Application Story on Optimass 9000 meters was published in the June edition of<br />

Instrumentation magazine – in the middle of an article by ABB on selecting flowmeters!<br />

STRAIGHT TALK<br />

A Texas asphalt facility<br />

has 6 x 9000 S100s<br />

installed for tanker<br />

loading.<br />

These meters have been<br />

supplied <strong>with</strong> steam<br />

heating jackets as well.<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.45


Application Story – Optimass 2000 at Shell Canada<br />

Shell’s Sarnia Manufacturing Centre (SMC) in<br />

Ontario is also referred to as Shell’s Corunna<br />

Refinery. It is located on the St Clair river next to<br />

the US border and processes 72,000 barrels of<br />

crude oil per day. Shell Canada refines only low<br />

sulphur gasoline, which contains less than 150<br />

parts-per-million sulphur.<br />

Shell Canada Ltd purchased<br />

an <strong>OPTIMASS</strong> 2300F S150<br />

Custody Transfer version for<br />

use at the Sarnia site and on<br />

the right and above are<br />

pictures of the completed<br />

installation.<br />

This is our 3 rd installed 2000<br />

series meter, following the 2<br />

meters installed in<br />

Kazakhstan last month.<br />

STRAIGHT TALK<br />

Process details<br />

Media : Gasoline<br />

Temperature : 15.0 C<br />

Pressure : 3000 kPa<br />

Density : 884.0 kg/m³<br />

Viscosity : 0.7 mPa.s<br />

Flow type : Volume flow<br />

Flow : 300 m³/h<br />

With thanks to Angelo DelBuono of KAI Canada for this application note<br />

above: The Shell Sarnia site<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.46


Application Story – Carbon Black Production in Europe<br />

A carbon black producer in Europe has installed 5 of our high temperature<br />

Optimass 9000 meters to control the flow of oil at the reactors. Carbon black is<br />

used to improve the strength, durability and overall performance of a range of<br />

products including tyres and other mechanical rubber goods, as well as inks,<br />

paints, plastics and coatings<br />

Prior to purchase, our<br />

meters were tested against<br />

competitor’s meters and<br />

gave better results.<br />

STRAIGHT TALK<br />

Meter: Optimass MFS9000 S25<br />

Medium: FCC oil, or Etilen tar oil<br />

Flow range: 0-8000 kg/h<br />

Temperature: 230 C<br />

Pressure: 23 barg<br />

Density: 1,05..1,1 g/cm3<br />

Viscosity (SUS99C) : 120-330<br />

This company could rely on our local<br />

agents for good technical support and<br />

the high temperature meters provided<br />

the right options and accuracy at the<br />

right price.<br />

Our thanks to Frank Grunert of KLtd for this application note<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.47<br />

1


Application Story – Carbon Black Production in Europe<br />

A carbon black producer in Europe has installed 5 of our high temperature<br />

Optimass 9000 meters to control the flow of oil at the reactors. Carbon black is<br />

used to improve the strength, durability and overall performance of a range of<br />

products including tyres and other mechanical rubber goods, as well as inks,<br />

paints, plastics and coatings<br />

Prior to purchase, our<br />

meters were tested against<br />

competitor’s meters and<br />

gave better results.<br />

STRAIGHT TALK<br />

Meter: Optimass MFS9000 S25<br />

Medium: FCC oil, or Etilen tar oil<br />

Flow range: 0-8000 kg/h<br />

Temperature: 230 C<br />

Pressure: 23 barg<br />

Density: 1,05..1,1 g/cm3<br />

Viscosity (SUS99C) : 120-330<br />

This company could rely on our local<br />

agents for good technical support and<br />

the high temperature meters provided<br />

the right options and accuracy at the<br />

right price.<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.48


Application Story – 1 st Optimass 2000s installed in Kazakhstan<br />

KazMunayGas is the state-owned oil and gas<br />

company of Kazakhstan. It was founded in 2002 by<br />

merging Kazakhoil and Oil and Gas Transportation.<br />

KazMunaiGas Exploration Production (KMG EP) is a KazMunayGas -majorityowned<br />

oil and gas company producing crude oil, natural and associated gas from<br />

its hydrocarbon reserves on-shore in Kazakhstan. It was formed in March 2004<br />

through the merger of JSC UzenMunaiGas (UMG) and JSC EmbaMunaiGas<br />

(EMG) and was the 2nd largest Kazakh oil producing company in 2007.<br />

KMG EP is developing 46 fields in Western Kazakhstan, the largest being the<br />

Uzen field - in production since 1965 and accounting for more than 75% of<br />

reserves and 71% of 2007 production. This is where the first two Optimass<br />

2000s shipped out from KLtd have been installed for tank oil metering.<br />

Process Details<br />

Pressure: 10-39 Bar<br />

Temperature: 35˚C-55˚C<br />

Flow rates: 360-480 ton/hour<br />

Viscosity: 40-150 cSt,<br />

Petroleum type: tank oil (<strong>with</strong> high<br />

content of paraffin 70 %)<br />

STRAIGHT TALK<br />

With thanks to Yuriy Tuzhilov of Kanex <strong>Krohne</strong> Kazakhstan for this application<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.49<br />

1


Optimass<br />

Application Note<br />

One of the biggest Shell petrochemical production facilities in Europe is at SHELL Berre (close<br />

to Marseille),<br />

Application: Truck loading<br />

INDUSTRY: OIL AND GAS<br />

COUNTRY: FRANCE<br />

METER: <strong>OPTIMASS</strong> 7000 T 40 & T50<br />

The customer needs to load the exact quantity of SAP oil into the tanker to avoid any<br />

overloading. The trucks are then weighed on a weighbridge to get a custody transfer<br />

measurement of the mass. If there is an overload, the truck must come back to an offloading<br />

station, losing valuable operating time. If the tanker is not totally filled, then transportation costs<br />

increase.<br />

The previous installation was less than ideal, and 7 larger meters were replaced <strong>with</strong> Optimass<br />

T 40 and T 50 meters <strong>with</strong>out any pipeline modifications. This was a requirement, as Shell was<br />

not able to stop the loading stations in order to do the work.<br />

The measurement results were immediately excellent <strong>with</strong>out any special adjustment or field<br />

calibration of the meter. For a 26 ton fill, the measurement accuracy improved to ±0.2% <strong>with</strong><br />

Optimass from the previous ±0.8 to 2.5%.<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.50


Application: Loading Station<br />

Why KROHNE? KROHNE France provided the support and convinced the<br />

customer that they could save money <strong>with</strong> the increased<br />

accuracy of the installation of Optimass.<br />

Problem: Unsatisfactory performance of existing meters.<br />

Solution: Improved accuracy meant more savings.<br />

2<br />

Process Parameters<br />

Product: SAP Oil<br />

Mass Flow: 40 – 60 t/h<br />

Temperature: 100 °C<br />

Viscosity: 83 -220 cSt<br />

Pressure: 3.9 – 6 bar<br />

Density: 920 – 1000<br />

k/m3<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.51


Coriolis Mass Flow<br />

Application Story – Wax Production in UK<br />

UK wax manufacturer Kerax Limited has installed an<br />

<strong>OPTIMASS</strong> 7300 mass flowmeter to improve the<br />

accuracy of production processes at its plant in<br />

Chorley, Lancashire.<br />

Application:<br />

Kerax produces a variety of different waxes to be used in making castings and as<br />

ingredients in products such as adhesives. Each formulation requires the<br />

blending of two or three types of wax plus a number of additives. The mechanical<br />

meter previously positioned on the input to the blending vessel was not able to<br />

provide the accuracy needed for Kerax’s increasingly stringent process control.<br />

Problem:<br />

The wax flowing through the<br />

meter can vary in density from<br />

0.8 to 1.0 kg/litre and in<br />

viscosity from 5.5 cP to 1,200<br />

cP. It can be flowing at rates<br />

varying from 1.8 to 15 tonnes /<br />

hour <strong>with</strong> pressures from 1.4 bar<br />

to more than 4.1 bar at<br />

temperatures ranging from 20 to<br />

120°C.<br />

Solution: <strong>OPTIMASS</strong> 7300-T 50<br />

The installed <strong>OPTIMASS</strong> 7300<br />

Coriolis mass flowmeter is capable<br />

of handling the wide variation in<br />

process conditions whilst still<br />

delivering accuracy of +/- 0.1 per<br />

cent.<br />

STRAIGHT TALK<br />

To maintain a consistent product<br />

temperature, the <strong>OPTIMASS</strong> meter is<br />

fitted <strong>with</strong> a heating jacket that can be fed<br />

<strong>with</strong> hot water or steam.<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.52


Application Story – Siemens Gasification Test Rig<br />

STRAIGHT TALK<br />

The Siemens gasification centre<br />

in Freiberg, Germany, is one of<br />

the most comprehensive<br />

gasification test facilities in the<br />

world. Its gasification reactor is<br />

rated at five MWth and can be<br />

adjusted to different feedstock<br />

conditions. The facility also<br />

includes a range of feedstock<br />

preparation systems and related<br />

gas cleaning process units.<br />

A test rig for large-scale, high-pressure feeding tests and further equipment for coal<br />

and slag analysis (e.g. fluidization and viscosity) complement the facilities. With this<br />

equipment, a broad range of test conditions can be simulated.<br />

For the examination of fouling in heat exchangers,<br />

a test rig was designed to gain experience when<br />

preheating process water up to 220°C. Thermo oil<br />

is used as a heating medium in the heat exchanger.<br />

Both the monitoring of temperature and a reliable<br />

monitoring of the volume flow are decisive factors<br />

for the evaluation.<br />

An <strong>OPTIMASS</strong> 9000 from KROHNE was installed<br />

to control the thermo oil volume flow. The mass<br />

flowmeter records the volume flow of the thermo oil<br />

at 230 °C and 10 barg. The maximal permissible<br />

temperature of the thermo oil is 300°C.<br />

Optimass 9000 S25<br />

Medium: Heating oil<br />

Flow rate:2500 kg/h<br />

Temperature: 260°C<br />

Pressure:1-11 bar<br />

With thanks to Klaus Loetsch of KMT Freiburg for this application note<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.53<br />

1


Application Story<br />

Top gas mud density measurement in Nova hut a.s.<br />

ISPAT Nova Hut a.s. is one of the largest metallurgic plants in the Czech Republic.<br />

It is an integrated steelmaking concern <strong>with</strong> a metallurgical production and large<br />

engineering shops. The metallurgical production is of a mass character, the main<br />

products being welded and hot-rolled seamless steel pipes, long products and wire<br />

rod, hot rolled sheets and strips. The engineering production (e.g. steel mining<br />

supports) is geared for batch production. Their coking plant is the largest coke<br />

producer in the Czech Republic.<br />

ISPAT Nova Hut has been using several hundreds of KROHNE magnetic inductive<br />

flowmeters and flow controllers (mainly on water measurements) and additionally<br />

ultrasonic flowmeters (on demineralised water and tar), level radar (blast furnace<br />

stock level, hydrochloric acid level measurement) and mass flowmeters (fuel oil, top<br />

gas and steel sludge measurement). All instruments have been subjected to<br />

demanding operating conditions.<br />

In the blast furnace, during the pig iron production process, a lot of top gas is<br />

generated. The gas (<strong>with</strong> temperature 200 – 500°C) contains from 30 to 100 g/m3 of<br />

dust. The gas is cleaned <strong>with</strong> sprinkling water, which then flows into settling basins.<br />

Here the mud settles and then it is pumped first to thickeners and after thickening to a<br />

separator. For the process control it is necessary to know the density of the mud<br />

pumped from basins to thickeners and from thickeners to the separator.<br />

The customer had been using nucleonic density meters for 10 years. These meters<br />

require special approvals and checks and a lot of maintenance. <strong>More</strong>over they could<br />

not be in operation <strong>with</strong>out product flow. For this reason the customer decided to test<br />

2 KROHNE mass flowmeters Corimass MFM 4085 G+ - 1500 G. After 6 months´<br />

testing, 8 pieces of Optimass T50 mass flowmeters were ordered.<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.54


Ovako Steel at Hofors<br />

Why <strong>Krohne</strong><br />

No maintenance necessary<br />

Low pressure drop<br />

High accuracy<br />

Optimised burner control<br />

Excellent support from Fagerberg Sweden<br />

Application Story<br />

Burner control in Sweden<br />

Steel is the world's<br />

leading producer of steel for rolling<br />

bearings and, in addition, the company<br />

has a strong position <strong>with</strong>in the field of<br />

low alloy special steels. Their annual<br />

production capacity is 525 000 tonnes<br />

of special engineering steel. Ovako<br />

Steel's metallurgical facilities are<br />

located at Hofors, Sweden.<br />

Our Optimass 7050 15 T <strong>with</strong> heating jacket shown in the picture below is being<br />

used for burner control. We also have 24 of our low flow 7100 meters (now<br />

renamed 3000) being used in other applications in Ovako.<br />

Optimass T 15 HJ<br />

Medium: Oil<br />

Pressure: 4 bar.<br />

Temp: 80ºC<br />

Density: 886 kg/m3<br />

Range: 0 - 4500 kg/h<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.55


Application Story – Fuel Consumption in Norway<br />

4 Optimass 1300 C S25 meters were purchased for fuel monitoring on ferries in<br />

Norway <strong>with</strong> very good results. The first installation is now saving about 1000 litre<br />

diesel per day, which is about 120.000 Euro p.a. The second pair have now been<br />

commissioned on another ferry and we expect more orders to be forthcoming.<br />

The logging system is delivered by Bentzen Elektro. It uses 2 of our very precise<br />

<strong>OPTIMASS</strong> 1300C flow meters that measure the difference between input and<br />

output. One meter is on the input side of the fuel line and one on the return pipe.<br />

The difference measures the fuel consumption.<br />

The basis of the system is a 6.5’’ TFT<br />

colour screen displaying the consumption<br />

based on different criteria, like time or<br />

distance travelled. The screen has a<br />

touch function and is easy to operate.<br />

There is an alarm function to show when<br />

the consumption is too high. The log<br />

function is in the screen and is saved in<br />

an USB-stick, which can be down loaded<br />

to a PC to keep a history of consumed<br />

fuel.<br />

The system is very flexible and can be<br />

extended where required to log the<br />

consumption <strong>with</strong> regard to number of<br />

revolutions, pitch or speed,<br />

STRAIGHT TALK<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.56


Application Story<br />

Czech Republic Custody Transfer<br />

A T25 Optimass Meter was installed for Propane/Butane emptying of rail tankers<br />

<strong>with</strong> a capacity of approximately 42000 kg at BP in the Czech Republic. Accuracies<br />

of 0.2 to 0.3% were repeatedly achieved which included the uncertainty of the<br />

weighbridge used for the railcars. Resolutions of these weighbridges are typically<br />

in the tens of kilograms! This meter is installed as a Custody Transfer meter<br />

according to Czech Republic guidelines and directives.<br />

All weather emptying from railway tanks using Optimass<br />

Another Optimass T25 for Custody<br />

Transfer was subsequently<br />

installed at BP in Dysina near the<br />

city of Pilsen filling tank-trucks<br />

<strong>with</strong> propane/butane. The<br />

measurement error is approx. 30<br />

kg per 10000 kg of the gas, but it<br />

also comprises the error of the<br />

recomputation as the tank-trucks<br />

are filled according to mass but the<br />

distribution to end users is<br />

performed according to volume and<br />

the recomputation to mass is done<br />

acc. to special tables.<br />

Process Parameters<br />

Application:CT transfer of bulk<br />

Butane / Propane products<br />

Flow Rate: 12000 kg/h<br />

Pressure: 6-8 bar<br />

Temp: Ambient (-30 to +35°C)<br />

Process Parameters<br />

Application: CT transfer of bulk Butane /<br />

Propane products<br />

Flow Rate: Nominal flow rate of a 25 T<br />

is 34,500 kg/h, emptying at 14,000 kg/h<br />

(pressure drop 0,3 bar, velocity 15,4 m/s)<br />

Pressure: 7 to 12 bar<br />

Density: 560 kg/m3<br />

Temperature: Ambient (-30 to +35°C)<br />

The installation in Dysina<br />

Why KROHNE?<br />

KROHNE Czech Republic is known for their<br />

customer support and client was confident<br />

that the solution proposed would do the job.<br />

Our thanks to Radmilla Kompova of KROHNE CZ for this application story<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.57<br />

4


Coriolis Mass Flow<br />

Applications - CT<br />

Custody transfer measurement of propane - butane<br />

Propane-butane measurement for the BP CZ company, used for filling from railway<br />

tanks under the environment conditions (outside), the instrument is „custody<br />

transfer“ acc. to the CZ directives, during the first filling the tank contained 41100 kg<br />

<strong>with</strong> the pressure of 5 bar, our Optimass measured by 120 kg minus, the customer<br />

was satisfied.<br />

PDF created <strong>with</strong> pdfFactory trial version www.software-partners.co.uk<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.58


Coriolis Mass Flow<br />

Applications – Oil & Gas<br />

PDF created <strong>with</strong> pdfFactory trial version www.software-partners.co.uk<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.59


Coriolis Mass Flow<br />

Applications – Oil & Gas<br />

PDF created <strong>with</strong> pdfFactory trial version www.software-partners.co.uk<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.60


Coriolis Mass Flow<br />

The customer needs to load the exact<br />

quantity of SAP oil into the tanker to avoid<br />

any overloading. The trucks are then<br />

weighed on a weighbridge to get a custody<br />

transfer measurement. If there is an<br />

overload, the truck must come back<br />

to an offloading station, losing valuable<br />

operating time. If the tanker is not totally<br />

filled, then transportation costs increase.<br />

Applications – Dosing and Batching<br />

SHELL Berre (Marseille/France)<br />

Process Parameters<br />

Product: SAP Oil<br />

Mass Flow: 40 – 60 t/h<br />

Temperature: 100 °C<br />

Viscosity: 83 -220 cSt<br />

Pressure: 3.9 – 6 bar<br />

Density: 920 – 1000 k/m3<br />

PDF created <strong>with</strong> pdfFactory trial version www.software-partners.co.uk<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.61


Coriolis Mass Flow<br />

Applications – Dosing and Batching<br />

Benzine loading stations <strong>with</strong> <strong>OPTIMASS</strong>, Solvent Chemie, Chemie,<br />

Germany<br />

Process data:<br />

Flow: 50 t/h<br />

Density: 0.850 kg/l<br />

Temperature: 18 °C.<br />

Viskosityt 1 mPas<br />

Tanker loading <strong>with</strong> 6 <strong>OPTIMASS</strong><br />

meters T 40 EEx in connection <strong>with</strong><br />

the batch controller “Batchingmaster”<br />

from ibs-control<br />

PDF created <strong>with</strong> pdfFactory trial version www.software-partners.co.uk<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.62


Coriolis Mass Flow<br />

Installation 1: Suspended by two metal rods<br />

and two metal belts in a horizontal position<br />

from the top of the filling station.<br />

Process Conditions:<br />

Product: Tequila (alcohol)<br />

Temperature: 25 °C<br />

Pressure: 4 kg/cm2<br />

Density: 0.95 kg/l<br />

Flow rate: 640 l/min<br />

Applications – Food & Beverage<br />

Jose Cuervo Tequila - Filling Station in Mexico<br />

Fiscal measurement <strong>with</strong> 2 x <strong>OPTIMASS</strong> S40<br />

Connection: Tri Clamp<br />

Power supply: 120 V AC<br />

Output: pulse output to batch controller<br />

Note:<br />

The meters have been installed in such a way<br />

that they will always be full. This is good<br />

engineering practice for this type of application.<br />

Installation 2: in a horizontal pipeline<br />

PDF created <strong>with</strong> pdfFactory trial version www.software-partners.co.uk<br />

Copyright KROHNE, inc. , 2009 <strong>OPTIMASS</strong> Applications Page No.63

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!