plant, is permanently manned. Rajamäki plant is visited<br />
shortly once per day, due to requirements of legislation,<br />
but all operations are performed from the control centre.<br />
During the night time and weekend the operator can<br />
control the plants with a portable PC even from his home.<br />
6 EMISSIONS OF FLUIDISED BED COMBUSTION<br />
Emissions of Rajamäki plant have been measured by<br />
an independent authority. Table 1 shows emissions on 3<br />
MW partial load, i.e. below 30% of nominal capacity.<br />
Table I: Rajamäki heating plant emissions at 3 MW<br />
partial load<br />
Rajamäki Actual load: 3 MWth<br />
heating plant<br />
Performed by: Suomen<br />
Analyysipalvelut Oy<br />
Date:<br />
14.3.2008<br />
Parameter Value unit<br />
Flue gas temperature 51,8<br />
o<br />
C<br />
CO2 in flue gas 12, 3 ±0,7 %<br />
O2 in flue gas 8, 3 ±0,4 %<br />
Dust content 20 ± 4 mg/m 3 n<br />
Dust emission 0,14 ± 0,05 kg/h<br />
Dust contents red. at 6% O2 23 ± 5 mg/m 3 n<br />
Specific emissions 9 ± 3 mg/MJ<br />
NOx 97 ppm<br />
NO2 contents red. at 6% O2 236 ± 18 mg/m 3 n<br />
SO2