<strong>Technology</strong>/Method Woven Hose Lining/Adhesive<br />

Structural Rating<br />

Claimed<br />

Class IV (AWWA M28 Manual) fully structural independent liner<br />

• Composite <strong>of</strong> woven seamless textile jacket with resin and polymeric<br />

membrane<br />

Materials <strong>of</strong><br />

Composition<br />

• Aqua-Pipe is composed <strong>of</strong> two concentric, tubular, plain woven polyester<br />

jackets with a polymeric membrane bonded to the interior to ensure water<br />

tightness.<br />

• The liner is impregnated with a specific thermoset epoxy resin that allows a<br />

tight bond between the liner and the host pipe.<br />

Diameter Range,<br />

inches<br />

6 to 12 inches<br />

Thickness Range,<br />

inches<br />

3 to 6 mm<br />

Pressure Capacity,<br />

psi<br />

Maximum operating pressures up to 150 psi<br />

Temperature Range,<br />

o<br />

F<br />

35 o F to 100 o F<br />

Renewal Length, feet<br />

Up to 500 feet (150 meters) between access pits.<br />

The distance between access pits determines the length <strong>of</strong> the segment.<br />

Other Notes Hazen-Williams coefficient > 120<br />

III. <strong>Technology</strong> Design, Installation, and QA/QC In<strong>for</strong>mation<br />

Product Standards<br />

Aqua-Pipe is certified by NSF to NSF/ANSI 61 and under BNQ Standard 3660­<br />

950.<br />

Design Standards<br />

The mechanical properties <strong>of</strong> Aqua-Pipe exceed ASTM F1216 and ASTM F1743<br />

recommendations.<br />

Design Life Range 50+ years<br />

Installation Standards<br />

Aqua-Pipe is precisely aligned with the host pipe's point <strong>of</strong> entry and pulled<br />

through to the exit point.<br />

The shaping <strong>of</strong> Aqua-Pipe is achieved by pushing a pig through the hose using<br />

water pressure. Circulating hot water ensures the curing process. Pulled-in-Place<br />

Piping (PIPP) method.<br />

Installation<br />

Methodology<br />

This product requires the following cure time, temperature, and flush:<br />

• Day 1: Cure 1.5 hours at 65°C and 25 psi water pressure, then cure <strong>for</strong><br />

12 hours at ambient temperature and 50 psi water pressure<br />

• Day 2: Flush at 2.8 liters per minute <strong>for</strong> 24 hours at ambient temperature<br />

• Day 3: Cure <strong>for</strong> 24 hours at ambient temperature<br />

QA/QC<br />

Requires a 1 hour flush with potable water prior to being placed into service.<br />

No special procedures beyond standard manufacturer’s recommendations<br />

IV. Operation and <strong>Main</strong>tenance Requirements<br />

O&M Needs<br />

No particular maintenance needs; Pressure or dry taps <strong>for</strong> future service<br />

connections can be easily carried out with no special equipment<br />

Repair Requirements<br />

<strong>for</strong> Rehabilitated<br />

Sections<br />

Typically need to cut out defective pipe section and replace with new pipe.<br />

V. Costs<br />

List <strong>of</strong> parameters or key drivers <strong>for</strong> the costs.<br />

Set-up cost: mobilization, temporary by-pass installation, pit excavation &<br />

Key Cost Factors backfill, pipe cleaning & inspection, service plugging & reinstatement, lining,<br />

testing, disinfection & site restoration<br />

Material costs: liner, resin, new pipe & fittings including valves and hydrants<br />

Case Study Costs<br />

Hamilton = $133/feet (35% savings); Toronto = $137/feet (50% savings);<br />

Naperville = $186/feet (see case study)<br />

VI. Data Sources<br />

References http://www.sanexen.com/en/aquapipe/index.htm<br />

http://www.sanexen.com/en/aquapipe/tech_info_product.htm<br />

Communication with Valerie Belisle, Michael Davison and Joseph Loiacono<br />

A-61