<strong>Technology</strong>/Method CIPP/UV Light Cure<br />

Product Standards ASTM F 2019-03<br />

Design Standards Not available.<br />

Design Life Range 50 year<br />

Installation<br />

Not available.<br />

Standards<br />

Installation<br />

Methodology<br />

The liner is shipped in special containers and UV protected foil and can be stored<br />

<strong>for</strong> up to 6 months without refrigeration. Sewage flow needs to be either plugged<br />

or by-passed. After sewer is cleaned and CCTV inspected, the Blue-Tek liner is<br />

winched into the existing pipe, inflated with air (6 to 8 psi) and then cured using a<br />

UV light train that is pulled through the pipe. Special care is needed to ensure<br />

that the exterior film is not damaged during installation. After curing the inner<br />

film is removed and discarded and the liner post CCTV inspected.<br />

QA/QC • Verification <strong>of</strong> UV lamp intensity and number (wattage)<br />

• CCTV inspection <strong>of</strong> entire line be<strong>for</strong>e curing<br />

• Record <strong>of</strong> liners inner air pressure during curing<br />

• Documentation <strong>of</strong> curing speed (feet/min)<br />

• Resin reaction temperatures (infrared sensors)<br />

• CCTV documentation <strong>of</strong> curing process<br />

• Physical property tests on specimens from the liner, including watertightness<br />

porosity test<br />

IV. Operation and <strong>Main</strong>tenance Requirements<br />

O&M Needs Not available.<br />

Repair Requirements<br />

<strong>for</strong> Rehabilitated<br />

Sections<br />

Not available.<br />

V. Costs<br />

Key Cost Factors Not available.<br />

Case Study Costs Not available.<br />

References<br />

VI. Data Sources<br />

www.relineamerica.com<br />