Figure 4-37. Tensile Specimens for Denver 48-<strong>in</strong>. Downstream Sample: Before the Test (Left) and<br />

Follow<strong>in</strong>g the Test (Right)<br />

Table 4-19. Tensile Test Results for Denver 48-<strong>in</strong>. Downstream Sample<br />

Location on<br />

<strong>Pipe</strong><br />

Area<br />

(<strong>in</strong>. 2 )<br />

Peak Load<br />

(lb)<br />

56<br />

Peak Stress<br />

(psi)<br />

Tensile Modulus<br />

(psi)<br />

1 0.2733 785.36 2,874 405,345<br />

2 0.2611 813.76 3,117 364,283<br />

3 0.3203 862.47 2,693 405,639<br />

4 0.2888 867.73 3,005 288,786<br />

5 0.3467 1139.19 3,286 448,047<br />

Average and<br />

Std. Dev.<br />

- - 2,995±227 382,420±60,141<br />

Figure 4-38. Stress-Stra<strong>in</strong> Curves from Tensile Test<strong>in</strong>g for Denver 48-<strong>in</strong>. Downstream Sample