(average <strong>of</strong> 6,900 psi) and flexural modulus <strong>of</strong> elasticity (average <strong>of</strong> 490,000 psi) were both well above<br />
the specified values at the time <strong>of</strong> <strong>in</strong>stallation (4,500 psi and 250,000 psi, respectively). Overall<br />
comparisons can be found <strong>in</strong> Section 6.<br />
Table 4-13. Historic Sampl<strong>in</strong>g Results for the CIPP L<strong>in</strong>er Tested <strong>in</strong> 1995 (Denver 48-<strong>in</strong>. L<strong>in</strong>er)<br />
Sample Tensile<br />
Break<br />
Strength<br />
(psi)<br />
Tensile<br />
Elongation<br />
at Break<br />
(%)<br />
48<br />
Flexural<br />
Break<br />
Strength<br />
(psi)<br />
Flexural<br />
Modulus <strong>of</strong><br />
Elasticity<br />
(psi)<br />
1 2,500 1.8 7,400 520,000<br />
2 2,400 1.3 7,000 530,000<br />
3 2,100 1.3 6,500 470,000<br />
4 - - 6,400 430,000<br />
5 - - 7,300 520,000<br />
Mean 2,300 1.5 6,900 490,000<br />
Std Dev 170 0.2 400 40,000<br />
4.3.3 Sample Retrieval <strong>in</strong> 2010. Two samples, each approximately 2 ft × 2 ft, were exhumed<br />
from the <strong>in</strong>stalled l<strong>in</strong>er on May 20, 2010, by Wildcat Civil Services <strong>of</strong> Kiowa, CO with Jack Row, the<br />
General Super<strong>in</strong>tendent, on site. (The l<strong>in</strong>er age at this time was 23 years.) Both samples were taken from<br />
the crown <strong>of</strong> the pipe at a distance about 4 ft from manhole B-3 (one upstream and the other downstream<br />
<strong>of</strong> the manhole). The samples were sent to TTC for test<strong>in</strong>g. Figure 4-27 shows images <strong>of</strong> the recovered<br />
specimens.<br />
Figure 4-27. Images <strong>of</strong> the Recovered Samples from the Denver 48-<strong>in</strong>. L<strong>in</strong>er<br />
4.3.4 Annular Gap. Annular space measurements were not collected for this sample due to the<br />
circumstances <strong>of</strong> sample retrieval.<br />
4.3.5 L<strong>in</strong>er Thickness<br />
4.3.5.1 Downstream Sample. For determ<strong>in</strong><strong>in</strong>g the l<strong>in</strong>er thickness <strong>of</strong> the downstream sample, 10<br />
read<strong>in</strong>gs were taken at six different locations around the sample (a total <strong>of</strong> 60 read<strong>in</strong>gs) us<strong>in</strong>g a<br />
micrometer with a resolution <strong>of</strong> ±0.0001 <strong>in</strong>. The average calculated values and their standard deviations<br />
are shown <strong>in</strong> Figure 4-28. The weighted average for the sample thickness measurements was calculated<br />
to be 13.9 mm and the weighted error ±0.3 mm.