09.01.2013 Views

Retrospective Evaluation of Cured-in-Place Pipe - (NEPIS)(EPA ...

Retrospective Evaluation of Cured-in-Place Pipe - (NEPIS)(EPA ...

Retrospective Evaluation of Cured-in-Place Pipe - (NEPIS)(EPA ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Pr<strong>of</strong>ile Plot<br />

Red - Steel tube Green - Pre-buckl<strong>in</strong>g Blue - post-buckl<strong>in</strong>g<br />

5<br />

4<br />

3<br />

2<br />

1<br />

0<br />

-5 -4 -3 -2 -1 0 1 2 3 4 5<br />

-1<br />

-2<br />

-3<br />

-4<br />

-5<br />

Figure 4-8. Ovality <strong>of</strong> the Denver 8-<strong>in</strong>. L<strong>in</strong>er (Average <strong>of</strong> Three Cross-Sections Spaced 1 <strong>in</strong>. Apart)<br />

4.2.11 Flexural Test<strong>in</strong>g and Tensile Test<strong>in</strong>g. Flexural test<strong>in</strong>g on specimens taken from the 8-<strong>in</strong>.<br />

Denver l<strong>in</strong>er was carried out both by TTC and Insituform (the supplier <strong>of</strong> the orig<strong>in</strong>al CIPP l<strong>in</strong>er). The<br />

test preparations and results are described <strong>in</strong> detail for the TTC test<strong>in</strong>g and these are then compared with<br />

the results provided by Insituform from their test<strong>in</strong>g.<br />

At TTC, specimens as described <strong>in</strong> ASTM D790 and D638 were cut from the crown, spr<strong>in</strong>g l<strong>in</strong>e, and<br />

<strong>in</strong>vert <strong>of</strong> the retrieved CIPP l<strong>in</strong>er us<strong>in</strong>g a router and a band saw. A total <strong>of</strong> n<strong>in</strong>e specimens were prepared<br />

and tested (three from each location). The sides <strong>of</strong> specimens were smoothed us<strong>in</strong>g a gr<strong>in</strong>der. The water<br />

jet cutter could not be used as the dimensions <strong>of</strong> the l<strong>in</strong>er cutouts were too small to hold <strong>in</strong>side the cutt<strong>in</strong>g<br />

board. The specimens were marked as shown <strong>in</strong> Figure 4-9 and Table 4-6. The laboratory set-ups for the<br />

flexural and tensile test<strong>in</strong>g are shown <strong>in</strong> Figures 4-10 and 4-11, respectively. The results <strong>of</strong> the flexural<br />

and tensile test<strong>in</strong>g for the Denver 8-<strong>in</strong>. l<strong>in</strong>er are summarized <strong>in</strong> Tables 4-7 to 4-9 and Figures 4-12 to 4-<br />

13.<br />

31

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!