Table 4-5. Denver 8-<strong>in</strong>. L<strong>in</strong>er Annular Gap Measurements<br />

North End <strong>of</strong><br />

Specimens<br />

(mm)<br />

South End <strong>of</strong><br />

Specimens<br />

(mm)<br />

29<br />

North End <strong>of</strong><br />

Rema<strong>in</strong><strong>in</strong>g <strong>Pipe</strong><br />

(mm)<br />

South End <strong>of</strong><br />

Rema<strong>in</strong><strong>in</strong>g <strong>Pipe</strong><br />

(mm)<br />

Crown 3.31 0.66 1.04 0.13<br />

45° crown – Right SL 0.10 0.44 0.64 0.20<br />

Right spr<strong>in</strong>g l<strong>in</strong>e 2.55 0.43 0.46 0.58<br />

Right haunch 0.58 0.43 0.64 0.58<br />

Invert 1.76 0.59 0.71 1.24<br />

Left haunch 0.68 0.43 0.20 0.20<br />

Left spr<strong>in</strong>g l<strong>in</strong>e 0.89 0.59 0.20 0.20<br />

45° crown – Left SL 0.10 0.57 0.64 0.20<br />

4.2.8 L<strong>in</strong>er Thickness. A total <strong>of</strong> 72 read<strong>in</strong>gs were taken to measure the thickness at different<br />

locations around the pipe circumference. These read<strong>in</strong>gs were taken us<strong>in</strong>g a caliper with a resolution <strong>of</strong><br />

+0.0001 <strong>in</strong>. The average thickness <strong>of</strong> the l<strong>in</strong>er is shown <strong>in</strong> Figure 4-6. The thickness <strong>of</strong> the l<strong>in</strong>er was<br />

found to vary slightly around the circumference <strong>of</strong> the l<strong>in</strong>er with the maximum thickness at the crown<br />

(5.98 mm ± 0.07 mm) and slightly lower values at the spr<strong>in</strong>g l<strong>in</strong>e (5.93 mm ± 0.11 mm) and the <strong>in</strong>vert<br />

(5.91 mm ± 0.09 mm). This was attributed mostly to the erosion <strong>of</strong> the polyurethane coat<strong>in</strong>g layer<br />

(approximately 0.38 mm thick), orig<strong>in</strong>ally placed on the <strong>in</strong>ternal surface <strong>of</strong> the l<strong>in</strong>er, at the <strong>in</strong>vert zone.<br />

The average measured thicknesses after 25 years <strong>in</strong> service were all slightly lower than the designed<br />

thickness <strong>of</strong> the l<strong>in</strong>er (6 mm) although some <strong>in</strong>dividual read<strong>in</strong>gs were higher. No ultrasonic field<br />

measurements <strong>of</strong> l<strong>in</strong>er thickness were possible <strong>in</strong> the field and when attempted <strong>in</strong> the laboratory the<br />

measurements were not successful. A discussion <strong>of</strong> this issue is provided <strong>in</strong> Section 6.<br />

Figure 4-6. Average Thickness at Different Locations on the L<strong>in</strong>er