Table 8-5. Rehabilitation Specifications<br />

Utility Specification<br />

Thames Water BS13566 Part 4<br />

Severn Trent Water Not known. Design to Water Industry Specifications (WIS) 4-34-04<br />

and Water Research Centre (WRc) Sewer Rehabilitation Manual<br />

(SRM)<br />

Agglomeration de Chartres Own performance specification<br />

Agglomeration des Hauts-de- None. Design to Association Scientifique et Technique pour l’Eau et<br />

Bièvre<br />

l’Environnement (ASTEE) method.<br />

Gött<strong>in</strong>gen Stadtentwässerung Own specification<br />

Technische Betriebe der Stadt<br />

Leverkusen<br />

Own specification<br />

Public Utilities Board S<strong>in</strong>gapore Own specification based on WIS 4-34-04<br />

Queensland Urban Utilities EN13566 Part 4<br />

Sydney Water EPS 01 – Small sewers based on AS 2566 and ASTM F1216<br />

EPS 03 – Large sewers based on AS 2566 and ASTM F1216F<br />

EPS 09 – Oviform sewers based on WRc Manual<br />

Among the utilities with their own specifications, there are significant differences <strong>in</strong> the characteristics<br />

specified for type test<strong>in</strong>g. Table 8-6 shows the type tests specified.<br />

Table 8-6. Type Test<strong>in</strong>g Required <strong>in</strong> Specifications<br />

Utility Characteristics for Type Test<strong>in</strong>g<br />

Thames Water Per BS EN 13566. 10,000 hour creep, stra<strong>in</strong> corrosion, Thames’ own<br />

<strong>in</strong>filtration test<br />

Severn Trent Water Not known.<br />

Agglomeration de Chartres Not known<br />

Agglomeration des Hauts-de-Bièvre None. Design verification only<br />

Gött<strong>in</strong>gen Stadtentwässerung Creep resistance, tensile modulus, bend<strong>in</strong>g modulus. M<strong>in</strong>imum wall<br />

thickness is 6mm irrespective <strong>of</strong> design requirements<br />

Technische Betriebe der Stadt Creep resistance, tensile modulus, bend<strong>in</strong>g modulus. M<strong>in</strong>imum wall<br />

Leverkusen<br />

thickness is 5mm irrespective <strong>of</strong> design requirements<br />

Public Utilities Board S<strong>in</strong>gapore Flexural strength, tensile strength, compressive strength, shear strength,<br />

density, Barcol hardness<br />

Queensland Urban Utilities ISO 175; Darmstadt Abrasion Test; DIN 19253; Jett<strong>in</strong>g Resistance Test;<br />

EN 1542; EN1055.<br />

Sydney Water Long term flexural modulus –manufacturers’ data<br />

Structural design <strong>of</strong> CIPP l<strong>in</strong>ers is most commonly undertaken by the contractor. Thames Water performs<br />

random <strong>in</strong>-house design checks, as does Sydney Water. Queensland Urban Utilities and PUB S<strong>in</strong>gapore<br />

do some design <strong>in</strong> house and have some done by the contractors, and Gött<strong>in</strong>gen has all design done by an<br />

<strong>in</strong>dependent consult<strong>in</strong>g eng<strong>in</strong>eer. All the others have design undertaken by the <strong>in</strong>stall<strong>in</strong>g contractor.<br />

8.4 Preparation and Supervision<br />

All <strong>of</strong> the utilities <strong>in</strong>terviewed agreed that preparation and supervision are critical elements <strong>in</strong> achiev<strong>in</strong>g a<br />

successful <strong>in</strong>stallation. Their importance had generally been learned through bad experiences when either<br />

or both had been <strong>in</strong>adequate. Table 8-7 shows the different approaches to preparation and supervision.<br />