Simulation of electric and magnetic fields using FEMM - FH Aachen ...
Simulation of electric and magnetic fields using FEMM - FH Aachen ...
Simulation of electric and magnetic fields using FEMM - FH Aachen ...
Create successful ePaper yourself
Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.
Figure 1-67Contour<br />
Use function to draw the plot <strong>of</strong> <strong>electric</strong> field.“E,t” (tangential <strong>electric</strong>al field<br />
intensity) plot is shown below.<br />
Figure 1-68E,t plot<br />
1.4.9 Compare with theoretical values<br />
Because the △U=constant=23kV so voltage on each layer can be easily calculated.<br />
U1=92kV U2=69kV U3=46kV U4=23kV