<strong>Comfort</strong> functions<br />
A<br />
B<br />
C<br />
D<br />
E<br />
F<br />
G<br />
X<br />
D.34<br />
Redline<br />
Function<br />
Protection of an electrical<br />
installation and all electrical and<br />
electronic devices connected to this<br />
installation against destructive<br />
overvoltage surges. Such voltage<br />
surges can be generated by<br />
lightning induced currents, by<br />
network-polluting devices such as<br />
motors, frequency-converters,<br />
dimmers etc. and by power supplier<br />
network switching operations.<br />
Performance<br />
Energy impulse wave<br />
Technology<br />
Response time<br />
Thermal fuse<br />
Thermal fuse healty indication<br />
Nominal voltage<br />
Frequency<br />
Protection mode<br />
Useable in network<br />
Operating temperature<br />
Screws<br />
Terminal capacity: min<br />
max<br />
More technical data<br />
Dimensions<br />
website<br />
pg D.46<br />
Surge Arresters<br />
SurgeGuard<br />
Applications<br />
SurgeGuard surge arresters cover the protection of home appliances (TV,<br />
HiFi, VCR, laundry-machine, dishwasher, ...), commercial building<br />
equipment (computer and data communication network, intrusion and fire<br />
alarm system, access-control and building automation system), industrial<br />
equipment (PLC, instrumentation, medical apparatus, monitoring devices)<br />
and even the protection of entire off-shore drilling platforms.<br />
Features<br />
Single and multi-pole devices (for TNC and IT respectively TNS and TT<br />
energy supplier networks); class 1 high energy deviation (10/350) and<br />
class 2 medium energy deviation (3/20) devices available; high current<br />
combined with low protection voltage; plug-in and monoblock devices<br />
both with and without voltage free signalling contact.<br />
In addition, all MOV-based devices have a built-in thermal fuse, to isolate<br />
the device from the rest of the installation in case of short-circuit or thermal<br />
runaway.<br />
A special low energy surge-suppression device (Sine Wave Tracking) is<br />
also part of this range of devices.<br />
Standards<br />
NF C61-740, IEC 61643-1<br />
Class 1<br />
Single pole monoblock<br />
10/350 µs<br />
Closed spark-gap<br />