<strong>Comfort</strong> functions<br />

A<br />

B<br />

C<br />

D<br />

E<br />

F<br />

G<br />

X<br />

D.16<br />

Redline<br />

Function<br />

Conditioning of incoming<br />

impulses to exact predictable<br />

output impulses.<br />

Standard<br />

IEC 60669-2-3<br />

Performance<br />

Contacts<br />

Contact spacing / material<br />

Spacing between control and load circuit<br />

Isolation voltage contact/contact<br />

Isolation voltage contact/magnetic system<br />

Switching capacity<br />

Incandescent lamp load<br />

Fluorescent lamp load, lead-lag circuit<br />

Fluorescent lamp load, inductive or capacitive<br />

Fluorescent lamp load, parallel compensated<br />

Electronic ballast load<br />

Inductive load, cos ϕ = 0.6 at 230V<br />

DC switching capacity<br />

Minimum contact load<br />

Time range<br />

Mechanical service life (1)<br />

Electrical service life, cos ϕ = 1 (1)<br />

Electrical service life, cos ϕ = 0.6 (1)<br />

Electrical service life, 1000W incandescent lamp (1)<br />

Screws<br />

Terminal capacity: min<br />

max<br />

Control system<br />

Control voltage range<br />

Relative duty at rated voltage<br />

Minimum duration of command impulse<br />

Operating temperature range<br />

Power consumption<br />

Maximum load of illuminated push-buttons<br />

Inrush current at 230V (first µs)<br />

Screws<br />

Terminal capacity: min<br />

max<br />

(1) Guaranteed at a switching frequency of 1000/h.<br />

Time Relays<br />

Pulsar T<br />

Applications<br />

From the delayed lighting of driveways (to avoid unnecesary on/off<br />

switching), to after-circulation of a pump (to build in some hysteresis,<br />

again to avoid continuous on/off switching) to the post-present<br />

ventilation of a meeting-room.<br />

Features<br />

Devices with delay on (ON), delay off (OFF), combined on-off-delay (OO),<br />

astable (AS), positive edge single shot (PS) negative edge single shot (NS)<br />

and even with all the above combined in one multi-function (MF) device<br />

are available. User presettable prescaler and time. In the case of the<br />

multi-function relay, the function itself is also user selectable. All devices<br />

have an internal step-down voltage converter. Therefore an AC as well as<br />

a DC supply and a very wide range of supply-voltages can be used to<br />

operate those devices. The loss-proof safety terminals are equipped with<br />

Pozidriv screws and have IP20 protection degree.<br />

Electronic time relays with simple or multifunction<br />

0.5mm/AgSnO2<br />

3mm<br />

250V<br />

250V<br />

10A/250V<br />

1000W<br />

1000W<br />

1000W<br />

500W<br />

700W; ION ≤ 70A/10 ms<br />

650W<br />

100W<br />

4V/10mA<br />

0.1s. ... 40h<br />

>107 >105 >104 >105 Pozidriv 1<br />

1x0.5 mm2 1x12 mm2 or 2x6 mm2 12 ... 230VUC (=DC or AC 50/60Hz)<br />

100%<br />

50ms<br />

-20 ... +50°C<br />

0.2 ... 2.5W<br />

NOT ALLOWED<br />

6 ... 25mA for all voltage-range<br />

Pozidriv 1<br />

1x0.5 mm 2<br />

1x12 mm 2 or 2x6 mm 2