08.01.2013 Views

Comfort Functions - GE Industrial Solutions

Comfort Functions - GE Industrial Solutions

Comfort Functions - GE Industrial Solutions

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Comfort</strong> functions<br />

A<br />

B<br />

C<br />

D<br />

E<br />

F<br />

G<br />

X<br />

D.14<br />

Redline<br />

Standards<br />

VDE 0632, BS EN 60669-1<br />

More technical data<br />

Dimensions<br />

website<br />

pg D.39<br />

Performance<br />

Contacts<br />

Contact spacing / material<br />

Isolation voltage contact/contact<br />

Switching capacity<br />

Incandescent lamp load<br />

Fluorescent lamp load, lead-lag circuit<br />

Fluorescent lamp load, inductive or capacitive<br />

Fluorescent lamp load, parallel compensated<br />

Electronic ballast load<br />

Inductive load, cos ϕ = 0.6 at 230V<br />

DC switching capacity<br />

Minimum contact load<br />

Time range<br />

Mechanical service life (1)<br />

Electrical service life, cos = 1 (1)<br />

Electrical service life, cos ϕ = 0.6 (1)<br />

Electrical service life, 1000W incandescent lamp (1)<br />

Screws<br />

Terminal capacity: min<br />

max<br />

Control system<br />

Control voltage range<br />

Relative duty at rated voltage<br />

Minimum duration of command impulse<br />

Operating temperature range<br />

Power consumption<br />

Maximum load of illuminated push-buttons<br />

Inrush current at 230V (first µs)<br />

Continuous excitation current<br />

Screws<br />

Terminal capacity: min<br />

max<br />

(1) Guaranteed at a switching frequency of 1000/h<br />

Staircase Switches<br />

Pulsar TS<br />

Function<br />

Push-button operated single-shot timer, switching the power to the load<br />

after the push-button has been pushed briefly, and switching off again<br />

after the presetted time has elapsed.<br />

Applications<br />

Lighting or ventilation of staircases, basements, halls, etc.<br />

Features<br />

User adjustable time. Electromechanical or digital clockwork. Manual<br />

override off or on possible at all times. 3 or 4 wire wiring possible. Device<br />

with pre-extinction warning available. The safety terminals are equipped<br />

with captive Pozidriv screws and have IP20 protection degree.<br />

PLT S EM<br />

3mm/AgSnO2<br />

400V<br />

16A/250V<br />

2300W<br />

3500W<br />

1300W<br />

1000W<br />

2300W; ION ≤ 140A/10ms<br />

1300W<br />

-<br />

6V/50mA<br />

0.5 … 5min.<br />

>5x104 >5x104 >2x104 >5x104 Pozidriv 1<br />

1x0.5mm2 1x6mm2 or 2x2.5mm2 0.9…1.1xUn<br />

100%<br />

50ms / 50ms<br />

-5...+60°C<br />

-<br />

50mA<br />

1A<br />

-<br />

Pozidriv 1<br />

1x0.5mm 2<br />

1x6mm 2 or 2x2.5mm 2<br />

PLT S EF<br />

0.5mm/AgSnO2<br />

400V<br />

16A/250V<br />

2000W<br />

1000W<br />

1000W<br />

500W<br />

700W; ION ≤ 70A/10ms<br />

650W<br />

-<br />

4V/10mA<br />

0.5 … 12min.<br />

>107 >105 >104 >105 Pozidriv 1<br />

1x0.5mm2 1x6mm2 or 2x2.5mm2 0.9…1.1xUn<br />

100%<br />

50ms / 50ms<br />

-20...+50°C<br />

-<br />

150mA<br />

330mA<br />

20mA<br />

Pozidriv 1<br />

1x0.5mm 2<br />

1x6mm 2 or 2x2.5mm 2

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!