10A<br />
0.5 mm/AgCdO 10<br />
3 mm<br />
250V<br />
400V<br />
10A/250V<br />
1000W<br />
1000W<br />
1000W<br />
Not allowed<br />
700W; ION ≤ 70A/10 ms<br />
650W<br />
100W<br />
4V/10mA<br />
1000/h<br />
>107 >105 >104 >105 Pozidriv 1<br />
1x0.5 mm2 1x6 mm2 or 2x2.5 mm2 0.9 ... 1.1xUn<br />
100%<br />
-<br />
50 ms / 800 ms<br />
-20 ... +50°C<br />
30mA<br />
-<br />
-<br />
3.5W<br />
-<br />
Pozidriv 1<br />
1x0.5 mm 2<br />
1x6 mm 2 or 2x2.5 mm 2<br />
16A<br />
3 mm/AgSnO2<br />
> 6 mm<br />
400V<br />
400V<br />
16A/250V; 10A/400V<br />
10A (2300W)<br />
16A (3500W)<br />
10A (1300W)<br />
4A (500W)<br />
10A (2300W); ION ≤ 140A/10 ms<br />
10A (1300W)<br />
100W<br />
6V/50mA<br />
1000/h<br />
>106 >105 > 2x104 >105 Pozidriv 1<br />
1x0.5 mm2 1x6 mm2 or 2x2.5 mm2 0.9 ... 1.1xUn<br />
100% / 60%<br />
100% for 1&2 poles, 1h for 4 poles<br />
50 ms / -<br />
-5 ... +50°C<br />
5mA<br />
10mA<br />
15mA<br />
7W for 1 pole, 10 for 2 poles, 20 for 4 poles<br />
0.06µF (= ±200 m.)<br />
Pozidriv 1<br />
1x0.5 mm 2<br />
1x6 mm 2 or 2x2.5 mm 2<br />
25A<br />
2x2 mm/AgSnO2<br />
> 6 mm<br />
400V<br />
400V<br />
25A/250V; 16A/400V<br />
16A (3600W)<br />
25A (5500W)<br />
16A (2000W)<br />
8A (1000W)<br />
10A (2300W); ION ≤ 140A/10 ms<br />
16A (2000W)<br />
150W<br />
12V/150mA<br />
1000/h<br />
>106 >105 > 2x104 >105 Pozidriv 1<br />
1x0.5 mm2 1x6 mm2 or 2x2.5 mm2 0.9 ... 1.1xUn<br />
100% / 60%<br />
100% for 1&2 poles, 1h for 4 poles<br />
50 ms / -<br />
-5 ... +50°C<br />
5mA<br />
10mA<br />
15mA<br />
7W for 1 pole, 10 for 2 poles, 20 for 4 poles<br />
0.06µF (= ±200 m.)<br />
Pozidriv 1<br />
1x0.5 mm 2<br />
1x6 mm 2 or 2x2.5 mm 2<br />
Redline<br />
1. Special care must be taken when connecting electromechanical impulse switches with central command. Terminals A1, B1 and C1 must be connected to the same voltage (I.e.<br />
live), whereas A2 must be connected to the opposite voltage (I.e. neutral). Incorrect connection I.e. different voltages on A1, B1 and C1 will destroy the central command circuit<br />
immediately after energising.<br />
2. If several impulse switches are going to be permanently energised, please ensure that there is adequate ventilation in accordance with the power loss calculation.<br />
As a rule of thumb, use a 1/2 mod spacer every 2nd impulse switch when continuously energised.<br />