RXF ROTARY SCREW COMPRESSOR UNITS<br />

FORMS<br />

070.410-IOM (JUL 11)<br />

Page 57<br />

Page 3 Unit Serial # _____________________________ Frick Order No: ____________________________<br />

Compressor Motor Setpoints and Information<br />

Motor Name Plate VFD Manufacturer ________________<br />

Motor Amps ___________ Maximum Drive Output ___ % Frame Size ______________<br />

Volts ___________ Minimum Drive Output ___ % H.P. ____________________<br />

Service Factor ___________ Remote Control RPM ___________________<br />

Horsepower ___________ Rate Of <strong>Inc</strong>rease ________ % Delay ____ Sec Serial # _________________<br />

CT Factor ___________ Rate Of Decrease _______ % Delay ____ Sec Service Factor ___________<br />

Recycle Delay __________ Min Capacity Control Voltage _________________<br />

High Motor Amps When Slide Valve Reaches ________ % Hz _____________________<br />

Load Inhibit______________ Drive Speed Reaches ________ % Design _________________<br />

Force Unload__________ Variable Speed Min. Slide Valve Position _______ % Code ___________________<br />

Warning________ Delay ___ Sec Skip Frequency Bands Bearing Type ________________<br />

Shutdown________ Delay ___ Sec Bottom Top Motor Coupling _____________<br />

_______ ______<br />

Low Motor Amps _______ ______<br />

Shut Down ________ Delay ______ Sec _______ ______<br />

Confirmed Running Motor Amps _______ _______ ______<br />

Starting Motor Amps Ignore Period ________ Sec _______ ______<br />

Vyper Coolant Setpoints<br />

Vyper Standby Time ______ Vyper Coolant Low Temp. Alarm______ Delay ______ Shutdown ______ Delay ________<br />

High Temp. Alarm______ Delay ______ Shutdown ______ Delay ________<br />

PHD Monitoring Setpoints Condenser Control<br />

Compressor Bearing ____________ Condenser Control Setpoint _____________<br />

Suction End Delay Discharge End Delay Digital <strong>Controls</strong> Step Order<br />

High Warning ______ gF _____ Sec High Warning _____ gF _____ Sec Module A ________<br />

High Shutdown ____ gF _____ Sec High Shutdown ____ gF _____ Sec Module B ________<br />

Module C ________<br />

Motor Bearing ______________ Module D ________<br />

Shaft Side Delay Opposite Shaft Side Delay Step Up Dead Band _________PSI<br />

High Warning _______ F _____ Sec High Warning ______ F _____ Sec Step Up Delay ________ Sec<br />

High Shutdown _____ F _____ Sec High Shutdown _____ F _____ Sec Step Down Dead Band _________PSI<br />

Step Down Delay ________ Sec<br />

Motor Stator _________________ High Pressure Override _________PSI<br />

High Pressure Override Delay _____ Sec<br />

Stator 1 Delay Stator 2 Delay<br />

High Warning ______F ______ Sec High Warning _____F ______ Sec Analog <strong>Controls</strong> Analog Output A ___________<br />

High Shutdown ____F ______ Sec High Shutdown ____F ______ Sec Analog Output B ___________<br />

Proportional Band ________PSI<br />

Stator 3 Delay Integration Time _______ Sec<br />

High Warning ______F ______ Sec High Limit ________PSI<br />

High Shutdown ____F ______ Sec Low Limit _______ Sec<br />

Miscellaneous<br />

Remote Capacity Deadband _______ % Max Slide Valve Timer _______ 1/10 Sec<br />

High Compressor Oil Pressure ________________ Max Discharge Pressure ___________PSI<br />

Shutdown _____PSI Delay ____ Sec Max Discharge and Oil Temp ________°F