CONNECTIONS<br />
1 MAIN OIL SUPPLY<br />
2 SLIDE VALVE PISTON<br />
3 LOW VI LIQUID INJECTION<br />
4 HIGH VI LIQUID INJECTION<br />
5 ECONOMIZER<br />
6 OIL DRAIN<br />
7 SUCTION PRESSURE<br />
8 CLOSED THREAD<br />
10 DISCHARGE PRESSURE<br />
11 LIQ. INJ. BLEED LINE<br />
12 COALESCER BLEED LINE<br />
RXF ROTARY SCREW COMPRESSOR UNITS<br />
MAINTENANCE<br />
RXF MODELS 12 through 50 with OIL PUMP (See OIL COOLING ADDITIONS)<br />
LEGEND (Cont.)<br />
15 VENT - UNLOADING<br />
16 THERMOWELL<br />
19 SUCTION PRESSURE<br />
NOTES:<br />
070.410-IOM (JUL 11)<br />
Page 43<br />
1. PRESSURE TRANSDUCERS INDICATE:<br />
PE-1 OIL PRESSURE<br />
PE-3 DISCHARGE PRESSURE<br />
PE-4 SUCTION PRESSURE<br />
2. TEMPRERATURE PROBES INDICATE:<br />
TE-1 SUCTION GAS TEMPERATURE<br />
TE-2 DISCHARGE GAS TEMPERATURE<br />
TE-3 LUBE OIL TEMPERATURE<br />
TE-4 SEPARATOR OIL TEMPERATURE<br />
3. TERMINATIONS "A" THROUGH "C" REFER<br />
TO CONNECTION POINTS FOR VARIOUS OP-<br />
TIONS.