070.410-IOM (JUL 11)<br />

Page 36<br />

RXF ROTARY SCREW COMPRESSOR UNITS<br />

MAINTENANCE<br />

TROUBLESHOOTING THE HYDRAULIC SYSTEM<br />

SYMpTOM pROBABLE CAUSES and CORRECTIONS<br />

SLIDE VALVE WILL NOT LOAD<br />

OR UNLOAD<br />

SLIDE VALVE WILL LOAD BUT<br />

WILL NOT UNLOAD<br />

SLIDE VALVE WILL UNLOAD<br />

BUT WILL NOT LOAD<br />

SLIDE STOP WILL NOT FUNC-<br />

TION IN EITHER DIRECTION<br />

SLIDE VALVE and/or SLIDE<br />

STOP WILL NOT MOVE<br />

Solenoid coil burned out. Replace coil.<br />

HV2 needle valve closed. Open valve.<br />

Solenoid spool may be stuck or centering spring broken. Free spool or replace spring.<br />

Solenoid may be mechanically actuated by inserting a piece of 3/16" rod against armature pin and pushing<br />

spool to opposite end. Push “A” side to confirm unload capability. If valve works, problem is electrical.<br />

Solenoid valve piston hung in bore or bolt loose. Check piston or tighten bolt.<br />

YY1 solenoid coil burned out. Replace coil.<br />

Check valve in solenoid valve piston bad. Replace or repair.<br />

Dirt inside solenoid valve preventing valve from operating both ways. Clean valve.<br />

Solenoid may be mechanical ly actuated by inserting a piece of 3/16" rod against armature pin and pushing<br />

spool to opposite end. Push YY1 valve to confirm unload capability. If valve works, problem is electrical.<br />

Slipper seals worn out or damaged. Replace.<br />

Check valve in slide valve piston sticking. Remove and clean check valve.<br />

YY2 solenoid coil burned out. Replace coil.<br />

Dirt inside solenoid valve preventing valve from operating both ways. Clean valve.<br />

Solenoid may be mechanically actuated by inserting a piece of 3/16" rod against armature pin<br />

and pushing spool to opposite end. If valve works, the problem is electrical.<br />

Solenoid coil burned out. Replace coils.<br />

Solenoid valve sticking. Replace valve.<br />

Slipper seals worn out or damaged.<br />

Unloader spindle or slide valve jammed.<br />

Slide stop indicator rod jammed.