03/11<br />

LAYOUT DRAWINGS:<br />

APUS 3 YL & PL<br />

The bottom plinth is 12 mm smaller in every side than the outer measurements of the product.<br />

PL = Top connection<br />

YL = Upper connection from behind<br />

APUS 3 YL & PL<br />

APUS 4 YL & PL APUS 7 YL & PL<br />

APUS 4 YL & PL,<br />

APUS 7 YL & PL<br />

PRODUCT INFORMATION:<br />

Thermal energy: 54-60 kWh<br />

Energy effi ciency: 79 %<br />

CO%: 0,1 %<br />

Nominal heat output: 1,3 kW / 15,5 hours<br />

Heat storage capacity:<br />

PRODUCT NUMBER:<br />

100% after 8,5 hours<br />

50% after 28,1 hours<br />

25% after 45,6 hours<br />

APUS<br />

<strong>Product</strong> <strong>Product</strong> number Weight kg Height mm<br />

APUS 3 YL 2NSTY-3 1750 1872<br />

APUS 4 YL 2NSTY-4 1710 1872<br />

APUS 7 YL 2NSTY-7 1710 1872<br />

APUS 3 PL 2NSTP-3 1750 1872<br />

APUS 4 PL 2NSTP-4 1710 1872<br />

APUS 7 PL 2NSTP-7 1710 1872<br />

NEEDED FOR ASSEMBLY:<br />

* Mortar 1 x 25 kg (not included in <strong>NunnaUuni</strong> delivery)<br />

<strong>NunnaUuni</strong> Oy reserves the right to make alterations


PRODUCTINFORMATION<br />

FLUE CONNECTION TABLE<br />

SAFETY DISTANCES TO COMBUSTIBLE MATERIALS<br />

According to EN 15250<br />

Behind On the<br />

sides<br />

<strong>Apus</strong> PL 50 50<br />

<strong>Apus</strong> YL (2 50 50<br />

1) The fl ue calculation values apply for countries that require fl ue calculation in accordance with the DIN 18160 and DIN EN 13384 standards. It is recommendable to contact<br />

chimney sweeper beforehand.<br />

2) YL = Upper connection from behind<br />

Take a notice of the countryspecifi c approvals in section 3<br />

NOTES!<br />

BAKING OVEN /<br />

BAKING SPACE<br />

Width<br />

[mm]<br />

approx.<br />

150x150<br />

Depth<br />

[mm]<br />

RECOMMENDED FLUE [mm] FLUE CONNECTION MEASUREMENTS [mm] INCOMING AIR<br />

approx.<br />

150x200<br />

Length<br />

fi replace /<br />

cooker<br />

[cm]<br />

approx.<br />

150x300<br />

FIREWOOD FLUE CALCULATION VALUES (1<br />

Max<br />

amount of<br />

wood<br />

[kg]<br />

Length<br />

baking oven<br />

[cm]<br />

round<br />

Ø [A] [B]<br />

Flue gas<br />

temperature<br />

[°C]<br />

Min. fl ue<br />

draught<br />

[Pa]<br />

The fl ue heat category required by the fi replace is T350.<br />

The recommended minimum fl ue height is 5 m with Ø180 mm. In countries where the fl ue calculation is required, should the calculation be done according to the instructions<br />

and regulations of the fl ue calculation.<br />

A damper designed for adjusting the draft is always recommended for a fl ue connection or fl ue.<br />

Country- and region-specifi c regulations must be adhered to when installing the fi replace<br />

[C]<br />

Mass fl ow<br />

[g/s]<br />

Incoming air<br />

pipe location<br />

L [mm]<br />

Burning heat<br />

output [kW]<br />

Replacement<br />

air<br />

unit<br />

Flue<br />

connection<br />

[A/B] Ø<br />

<strong>Apus</strong> PL - - 33 16 - 230 13 32,8 33,2 150 70<br />

<strong>Apus</strong> YL (2 - - 33 16 - 230 13 32,8 33,2 150 70<br />

<strong>Apus</strong> PL - - - 150 - - - 428 - 910273<br />

<strong>Apus</strong> YL (2 x x - 150-180 Ø 160 - 1710 428 - 910273<br />

03/11 <strong>NunnaUuni</strong> Oy reserves the right to make alterations<br />

HRT<br />

Burning air<br />

approx.<br />

m³/h