Burner requirement using holding circuit - program 12<br />
The output switches on when S2 < min and off when S1 > max. In other words, boiler requirement<br />
when S2 falls short of min in the upper storage area and switch-off when S1 exceeds<br />
max in the lower part of the tank.<br />
Preparation of hot water – program 16, 17<br />
Program 16 (only for speed version V D)<br />
By using the speed control the heat exchange outlet can be kept permanently at a constant<br />
temperature via the ultrafast sensor S2 (non-standard accessory). Low stand-by losses<br />
may occur. A volume flow switch S3 is not necessary.<br />
Program 17 (only for speed version V D)<br />
The speed control is only activated, if the volume flow switch S3 (non-standard accessory)<br />
indicates a flow. Very few stand-by losses may occur. When starting, the system is a little<br />
lazier and a volume flow switch is necessary.<br />