06.01.2013 Views

Technische Alternative - Varmt vand fra solen

Technische Alternative - Varmt vand fra solen

Technische Alternative - Varmt vand fra solen

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Burner requirement using holding circuit - program 12<br />

The output switches on when S2 < min and off when S1 > max. In other words, boiler requirement<br />

when S2 falls short of min in the upper storage area and switch-off when S1 exceeds<br />

max in the lower part of the tank.<br />

Preparation of hot water – program 16, 17<br />

Program 16 (only for speed version V D)<br />

By using the speed control the heat exchange outlet can be kept permanently at a constant<br />

temperature via the ultrafast sensor S2 (non-standard accessory). Low stand-by losses<br />

may occur. A volume flow switch S3 is not necessary.<br />

Program 17 (only for speed version V D)<br />

The speed control is only activated, if the volume flow switch S3 (non-standard accessory)<br />

indicates a flow. Very few stand-by losses may occur. When starting, the system is a little<br />

lazier and a volume flow switch is necessary.<br />

7

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!