System protection functions SYS PF:<br />

Collector excess<br />

temperature limiter<br />

Frost protection<br />

ON/OFF Shut-down threshold<br />

ON/OFF Switch-on threshold<br />

Switch-on threshold<br />

Shut-down threshold<br />

Collector excess temperature: Steam occurs in the system during standstill. When the<br />

system automatically switches on again, the pump does not have enough pressure to raise<br />

the fluid level above the highest point in the system (collector supply line). This represents a<br />

considerable load on the pump when there is no circulation. This function allows the pump to<br />

be blocked whenever the collector reaches a certain temperature (max �) until a second<br />

settable threshold (max �) has been crossed.<br />

ON / OFF Collector excess temperature limit ON/OFF (ex works = ON)<br />

max � Temperature above which the outputs set are to be blocked<br />

(ex works = 130°C)<br />

Setting range: 100°C to 200°C in increments of 1°C<br />

max � Temperature above which the outputs set are to be released.<br />

(ex works = 110°C)<br />

Setting range: 100°C to 199°C in increments of 1°C<br />