The parameter menu Par<br />

(Version number, program number, min, max, diff, auto/manual mode)<br />

14<br />

Code to enter menu Version number Program number<br />

Max limit switch-off<br />

threshold<br />

Min limit switch-off<br />

only displayed<br />

Automatic / Manual<br />

mode<br />

Max limit switch-on<br />

only displayed<br />

Difference switchon<br />

threshold<br />

Min limit switch-on<br />

threshold<br />

Difference switchoff<br />

threshold<br />

Time<br />

Once the parameter menu has been opened (using the code 32), the following tips and<br />

setting options appear depending on the program selected:<br />

V R 2.0 Software version of the device (V R = version with relay output, V D = speed version).<br />

It cannot be changed as it indicates the intelligence of the device and must<br />

be provided if there are any queries.<br />

PR/Prog Selection of the appropriate program according to the selected diagram. For a<br />

solar thermal system, that would be the number 0.