Block Diagrams EC3-61x / EC3-62x Rack Controller for 4 Compressors (EC3-62x: 3 Compressors and one Digital Scroll) Inputs 1 = Discharge temperatures of up to 4 compressors 2 = Suction pressure 3 = Discharge pressure 4 = Serial alarm inputs for up to 4 compressors 5 = Low pressure alarm 6 = High pressure alarm 7 = Oil level alarm 8 = Refrigerant level alarm Outputs 9 = for up to 4 compressors 10= to control a digital scroll (EC3-62x only) EC3-67x Rack Controller for Capacity Controlled Compressors Inputs 1 = Suction pressure 2 = Discharge pressure 3 = Serial alarm inputs for up to 6 compressors 4 = Low pressure alarm 5 = High pressure alarm 6 = Oil level alarm 7 = Refrigerant level alarm Outputs 8 = 12 outputs for up to 6x2 / 4x3 / 3x4 capacity controlled compressors 46 EC3-64x Rack Controller for 8 Compressors Inputs 1 = Suction pressure 2 = Discharge pressure 3 = Serial alarm inputs for up to 8 compressors 4 = Low pressure alarm 5 = High pressure alarm 6 = Oil level alarm 7 = Refrigerant level alarm Outputs 8 = For up to 8 compressors EC3-75x Condenser Controller Inputs 1 = Ambient temperature 2 = Humidity sensor 3 = Condensing pressure 4 = Serial alarm inputs for up to 6 fans 5 = High pressure alarm 6 = Heat recovery demand Outputs 7 = For up to 6 stages, from which 1 can be speed controlled 8 = Speed controlled fan (see 7) 9 = Heat recovery solenoid A2.5.1/0706/E

Block Diagrams EC3-81x Dual Ciruit Rack Controller (4 + 3 compressors) Inputs 1 = Discharge temperature inputs of 3 compressors 2 = Suction pressure group A 3 = Suction pressure group B 4 = Serial alarm input for each compressor respectively 5 = Refrigerant level alarm 6 = Low pressure alarm group A 7 = Low pressure alarm group B 8 = High pressure alarm 9 = Oil level alarm Outputs 10 = For up to 4 compressors suction group A 11 = For up to 3 compressors suction group B Technical Data A2.5.1/0706/E EC3-92x Rack and Condenser Controller Inputs 1 = Discharge temperature 2 = Ambient temperature 3 = Suction pressure 4 = Condensing pressure 5 = Serial alarm inputs for 4 compressors 6 = Low pressure alarm 7 = High pressure alarm 8 = Oil level alarm 9 = Refrigerant level alarm 10 = Serial alarms for 3 fans 11 = Heat recovery demand Outputs 12 = Up to 4 compressors 13 = Up to 3 fans, from with 1 fan can be speed controlled 14 = Speed controlled fan (see 13) 15= Heat recovery solenoid EC3 Controller ECD-000 Display Unit Supply voltage 24 VAC ±10%, 50/60 Hz Class II only Supply voltage via ECC-N10 from EC3 controller Power consumption 20 VA max. Display Numeric segmental display, LED red, 2½ digits, numeric value Plug-in connector Removable screw terminals device status and alarm indication Digital I/Os wire size 0.5 … 2.5 mm2 LEDs 1 x unit indicator bar/°C Analog I/O wire size 0.14 … 1.5 mm2 1 x alarm LED Communication LON: FTT10 Connecting lead 1,0 m (ECC-N10) interface TCP/IP: Ethernet with Web Server Operating Keys 4 operating keys: programming, service/up, select/down Temperature Temperature storage -20 … +65°C storage -20 … +65°C operating 0 … +60°C operating 0 … +60°C Humidity 0 … 80% r.h. non condensing Humidity 0 … 80% r.h. non condensing Protection class IP20 Protection class IP 65 (front panel with gasket) Weight ~ 810 g Weight ~ 52 g Mounting DIN-rail mount Mounting Panel mount (71x29mm cutout) 47

Block Diagrams<br />

EC3-61x / EC3-62x Rack Controller for 4 Compressors<br />

(EC3-62x: 3 Compressors and one Digital Scroll)<br />

Inputs<br />

1 = Discharge temperatures of up to 4 compressors<br />

2 = Suction pressure<br />

3 = Discharge pressure<br />

4 = Serial alarm inputs for up to 4 compressors<br />

5 = Low pressure alarm<br />

6 = High pressure alarm<br />

7 = Oil level alarm<br />

8 = Refrigerant level alarm<br />

Outputs<br />

9 = for up to 4 compressors<br />

10= to control a digital scroll (EC3-62x only)<br />

EC3-67x Rack Controller for Capacity Controlled Compressors<br />

Inputs<br />

1 = Suction pressure<br />

2 = Discharge pressure<br />

3 = Serial alarm inputs for up to 6 compressors<br />

4 = Low pressure alarm<br />

5 = High pressure alarm<br />

6 = Oil level alarm<br />

7 = Refrigerant level alarm<br />

Outputs<br />

8 = 12 outputs for up to 6x2 / 4x3 / 3x4 capacity<br />

controlled compressors<br />

46<br />

EC3-64x Rack Controller for 8 Compressors<br />

Inputs<br />

1 = Suction pressure<br />

2 = Discharge pressure<br />

3 = Serial alarm inputs for up to 8 compressors<br />

4 = Low pressure alarm<br />

5 = High pressure alarm<br />

6 = Oil level alarm<br />

7 = Refrigerant level alarm<br />

Outputs<br />

8 = For up to 8 compressors<br />

EC3-75x Condenser Controller<br />

Inputs<br />

1 = Ambient temperature<br />

2 = Humidity sensor<br />

3 = Condensing pressure<br />

4 = Serial alarm inputs for up to 6 fans<br />

5 = High pressure alarm<br />

6 = Heat recovery demand<br />

Outputs<br />

7 = For up to 6 stages, from which 1 can<br />

be speed controlled<br />

8 = Speed controlled fan (see 7)<br />

9 = Heat recovery solenoid<br />

A2.5.1/0706/E