827<br />

733.03<br />

(7) Furnish loop detector unit with an LED or LCD display<br />

indication <strong>of</strong> call strength ( L/L or equivalent). This display shall be a bar graph<br />

or numerical display with at least eight (8) discrete levels indicated.<br />

If vehicle detector types other than “loop” detectors are required<br />

by the plans, provide these detectors by separate bid item.<br />

Furnish TS-1 cabinets according to the <strong>Department</strong>’s Qualified Products List<br />

(QPL).<br />

B. Type TS-2.<br />

1. Furnish TS-2 cabinets that utilize a high speed data channel to connect<br />

the controller unit, malfunction management unit, rear panel (terminals <strong>and</strong><br />

facilities), detectors <strong>and</strong> bus interface units <strong>and</strong> also comply with the general<br />

requirements <strong>of</strong> 733.03. Furnish a prewired cabinet with malfunction management<br />

unit, loop detector units, <strong>and</strong> all accessory equipment as specified in NEMA TS-2,<br />

except as follows:<br />

a. Section 5.3.4, use detector racks for both Type 1 (A1) <strong>and</strong> Type 2<br />

(A2) controller units.<br />

b. Section 5.4.2.1, if a power service disconnect switch is located<br />

before the controller cabinet, the neutral (AC-) <strong>and</strong> the grounding bar in the<br />

controller cabinet shall be connected together.<br />

c. Section 5.4.2.7, provide an inc<strong>and</strong>escent type light.<br />

d. Section 5.4.2.7.2, provide the inc<strong>and</strong>escent lamp.<br />

e. Section 5.4.2.7.3, provide the door actuated light switch.<br />

f. Section 6.5.2.2.1, provide 2-channel detector units, without<br />

delay/extension features (Type A).<br />

g. Section 7.2, construct cabinets <strong>of</strong> cast or sheet aluminum.<br />

h. Section 7.3, provide a Size 5 cabinet for four phase or less pole<br />

mounted cabinets, Size 5 for four phase or less ground mounted cabinets, <strong>and</strong> Size<br />

6 for 5 phase or more ground mounted cabinets. Supply larger cabinets if required<br />

to house the equipment to meet the plan requirements; such as master controllers,<br />

preemption devices, 16 position backpanels or special detection units.<br />

i. Section 7.5.7, ensure that the police panel contains switches for<br />

AUTO/FLASH, SIGNALS ON/OFF <strong>and</strong> AUTO/MANUAL in the police panel.<br />

Furnish a pushbutton with a 5-foot (1.5 m) cord.<br />

j. Section 7.7.3, supply unpainted cabinets.<br />

2. Furnish loop detector <strong>and</strong> pedestrian inputs that have lightning/surge<br />

protection as specified in 733.03.A.2.f.<br />

3. Include loop detector racks with the necessary number <strong>of</strong> two-channel<br />

loop detector units with the cabinet. When shown on the plans, supply delay <strong>and</strong><br />

extension timing capability on the detector unit; otherwise, provide the controller<br />

unit s<strong>of</strong>tware with these features. If vehicle detector types other than “loop”<br />

detectors are required by the plans, provide these detector units by separate bid