733.03<br />

k. Switches. Furnish completely wired switches that are required<br />

for proper operation <strong>of</strong> specified equipment. Clearly <strong>and</strong> permanently label<br />

switches as to function <strong>and</strong> setting position, <strong>and</strong> ensure that they are accessible<br />

without the necessity <strong>of</strong> moving components.<br />

(1) Signal Shutdown Switch. Furnish a cabinet with a signal<br />

shutdown switch for turning <strong>of</strong>f the power to the signals at the intersection.<br />

Ensure that this switch only affects the power to the signals, <strong>and</strong> allows the<br />

controller to continue in operation. Locate the switch in the panel behind the small<br />

door-in-door (police door).<br />

(2) Auto/Flash Switch. Furnish a cabinet with a flash control<br />

switch for activating the flashing <strong>of</strong> vehicular signals in a preselected emergency<br />

flash display. Ensure that the operation <strong>of</strong> the flash control switch causes a<br />

flashing display even under conditions <strong>of</strong> controller unit malfunction or <strong>of</strong> its<br />

removal from the cabinet. Ensure that the operation <strong>of</strong> the switch overrides any<br />

operation comm<strong>and</strong>s from a local or remote time switch. Locate the switch in the<br />

panel behind the small door-in-door (police door).<br />

Program the transfer to <strong>and</strong> from flashing operation, when called<br />

remotely or by a local time switch, to occur only at points in the cycle allowed by<br />

the OMUTCD.<br />

(3) Automatic/Manual Transfer Switch. Furnish a cabinet<br />

with an automatic/manual transfer switch. In the automatic position, ensure that<br />

the controller unit automatically sequences the signal head displays. In the manual<br />

position, ensure that the signal phase or interval sequencing occurs only upon<br />

manual activation <strong>of</strong> the manual control pushbutton. Locate the switch in the<br />

door-in-door (police door). Ensure that it is unnecessary, when switching from<br />

manual to automatic operation, or vice versa, to do so at any certain time or to<br />

make any time adjustments.<br />

(4) Run/Stop-Time Switch. Furnish a cabinet with a run/stoptime<br />

switch that activates the controller stop-time feature when in the “stop-time”<br />

position. Locate the run/stop-time switch on a switch panel in the cabinet.<br />

(5) Controller Shutdown Switch. Furnish a cabinet with a<br />

controller shutdown switch that cuts <strong>of</strong>f power to the controller unit, conflict<br />

monitor, <strong>and</strong> detector units. Ensure that power is not cut <strong>of</strong>f to those components<br />

required to maintain flashing operation. Locate the controller shutdown switch on<br />

a switch panel in the cabinet.<br />

(6) Coordinated/Free Switch. Furnish controllers operated in<br />

a coordinated system with a coordinated/free switch. Ensure that this switch<br />

allows the choice <strong>of</strong> operating the controller under the supervision <strong>of</strong> a<br />

coordination device or operating the controller independently <strong>of</strong> coordination<br />

control. Locate the coordinated/free switch on a switch panel in the cabinet.<br />

(7) Detector Test Switches. Furnish momentary contact<br />

switches that will enter a vehicular or pedestrian call for any actuated phase.<br />

Furnish a switch for each actuated phase vehicular <strong>and</strong> pedestrian detection input.<br />

Conveniently group <strong>and</strong> label the switches.<br />