732.19<br />

wire in breakaway anchors shall be commercially pure lead <strong>of</strong> thickness 0.030 to<br />

0.042 inches (0.75 to 1.0 mm).<br />

732.19 Cable <strong>and</strong> Wire. Furnish cable <strong>and</strong> wire meeting the requirements <strong>of</strong><br />

Table 732.19-1 <strong>and</strong> rated at 600 volts with conductors <strong>of</strong> copper unless otherwise<br />

specified. Ensure that the cable or wire jacket is indelibly marked at intervals <strong>of</strong><br />

not more than 6 feet (2 m) with nomenclature stating the size, the type, the<br />

organization specifying the type, <strong>and</strong> the manufacturer’s name or trademark.<br />

Furnish materials according to the <strong>Department</strong>’s Qualified Products List (QPL).<br />

732.20 Power Service. Furnish risers for power service that are 1 to 1 1/2-inch<br />

(25 to 38 mm) diameter conduit <strong>and</strong> fittings according to 725.04 Furnish<br />

weatherheads that are threaded <strong>and</strong> made <strong>of</strong> aluminum or galvanized ferrous metal.<br />

Include a disconnect switch with enclosure.<br />

732.21 Disconnect Switch with Enclosure. Ensure that the switch enclosure<br />

is a UL listed watertight lockable stainless steel NEMA Type 4 supplied with the<br />

conduit hubs listed on the enclosure UL label. Furnish an enclosure that contains<br />

as a minimum a single-throw, 2 pole, solid neutral, fused safety disconnect switch<br />

(or circuit breaker) UL listed as suitable for a service disconnect with a minimum<br />

capacity <strong>of</strong> 30-amperes at 240 VAC. Ensure that the unit can be padlocked in both<br />

the “ON” <strong>and</strong> “OFF” positions.<br />

Furnish materials according to the <strong>Department</strong>’s Qualified Products List<br />

(QPL).<br />

732.22 Backplates. Furnish backplates constructed <strong>of</strong> wrought sheet<br />

aluminum, according to ASTM B 209 (B 209M), 6061-T6, .050 inch (1.3 mm)<br />

minimum thickness. Backplate base metal shall be anodized to maximize paint<br />

adhesion according to Mil-A-8625, Type II or Type I. Furnish backplates painted<br />

on both sides with at least two coats <strong>of</strong> flat black alkyd enamel paint or polyester<br />

powder coat (no epoxy) closely matching FED-STD-595b-37038. Furnish a<br />

backplate that extends 5 inches (125 mm) beyond the outside <strong>of</strong> the signal<br />

assembly on all sides. The overall outside shape <strong>of</strong> the installed backplate shall be<br />

rectangular. The backplate shall allow no gaps between the backplate <strong>and</strong> the<br />

signal head or between signal sections. A 2- inch (50 mm) wide continuous<br />

outside border <strong>of</strong> yellow or fluorescent yellow reflective sheeting shall be applied<br />

to the front face <strong>of</strong> the backplate. Reflective sheeting shall be Type H or J listed<br />

on the <strong>Department</strong>’s Qualified Products List. All assembly <strong>and</strong> mounting<br />

hardware shall be stainless steel conforming to 730.10. If used, machine nuts shall<br />

be thread-deforming or nylon locknuts. Rivets shall not be used for mounting the<br />

backplate to the signal head. A minimum <strong>of</strong> four mounting points shall be used on<br />

each signal section for attaching the backplate. Furnish all mounting hardware.<br />