732.04<br />

TABLE A-1<br />

Minimum Luminous Intensity Values (In C<strong>and</strong>elas)<br />

Vertical Angle Horizontal Angle<br />

RED YELLOW GREEN<br />

(Left/Right)<br />

-17.5<br />

2.5<br />

17.5<br />

51<br />

15<br />

127<br />

36<br />

67<br />

19<br />

-12.5<br />

2.5<br />

17.5<br />

110<br />

37<br />

273<br />

91<br />

143<br />

48<br />

-7.5<br />

-2.5<br />

+2.5<br />

+7.5<br />

+12.5<br />

-22.5<br />

-27.5<br />

2.5<br />

17.5<br />

2.5<br />

17.5<br />

2.5<br />

7.5<br />

12.5<br />

17.5<br />

2.5<br />

7.5<br />

12.5<br />

2.5<br />

7.5<br />

2.5<br />

7.5<br />

12.5<br />

17.5<br />

2.5<br />

17.5<br />

804<br />

281<br />

91<br />

358<br />

117<br />

150<br />

124<br />

84<br />

47<br />

69<br />

55<br />

40<br />

37<br />

29<br />

37<br />

29<br />

22<br />

11<br />

26<br />

18<br />

701<br />

228<br />

892<br />

291<br />

373<br />

309<br />

209<br />

118<br />

173<br />

137<br />

100<br />

91<br />

73<br />

91<br />

73<br />

55<br />

27<br />

64<br />

46<br />

366<br />

119<br />

466<br />

152<br />

195<br />

162<br />

109<br />

62<br />

90<br />

71<br />

52<br />

48<br />

38<br />

48<br />

38<br />

29<br />

14<br />

33<br />

24<br />

Notes:<br />

Luminous intensity values for equivalent left <strong>and</strong> right horizontal angles are the same.<br />

Tabulated values <strong>of</strong> luminous intensity are rounded to the nearest whole value.<br />

ARROW INDICATIONS (IN CANDELAS/M 2 )<br />

Yellow Green<br />

11,000 11,000<br />

c. LEDs for arrow indications shall be spread evenly across the illuminated portion<br />

<strong>of</strong> the arrow area. Arrow LED traffic signal lamp units shall meet VTCSH – Part<br />

3: LED Vehicle Arrow Traffic Signal Modules, March 2004. Arrow LED traffic<br />

signal lamp units shall be designed so that when operated over the specified<br />

ambient temperature <strong>and</strong> voltage ranges, the signal is clearly visible <strong>and</strong> attracts<br />

attention for a distance <strong>of</strong> at least 1300 feet (400 meters) under normal<br />

atmospheric conditions. Arrow LED traffic signal lamp units shall have 3 rows <strong>of</strong><br />

LEDs only.<br />

d. Measured chromaticity coordinates <strong>of</strong> LED traffic signal lamp units shall<br />

conform to the chromaticity requirements <strong>of</strong> the following table, for a minimum