05.01.2013 Views

2010 Construction and Material Specifications - Ohio Department of ...

2010 Construction and Material Specifications - Ohio Department of ...

2010 Construction and Material Specifications - Ohio Department of ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

711.24<br />

570M, Grade 36 or Grade 40. Minimum thickness for the internal plates is 0.074<br />

inch (1.88 mm). Debur all plates.<br />

The bearing manufacturer will furnish certified test data for the elastomer, base<br />

plate, steel laminates, <strong>and</strong> pro<strong>of</strong> load.<br />

The bearing manufacturer will produce one sample bearing for each bridge<br />

structure in the project plans. Ensure that the sample bearing for each bridge<br />

structure is <strong>of</strong> the same design <strong>and</strong> materials as the bearings furnished for that<br />

bridge structure. The bearing manufacturer will ship the completed sample<br />

bearings to an independent testing laboratory for destructive testing for the<br />

following physical properties:<br />

Hardness, Durometer A ASTM D2240<br />

Tensile Strength ASTM D412<br />

Elongation at Break ASTM D412<br />

Adhesion bond made during vulcanization ASTM D429, Method B<br />

Ensure that the bearing manufacturer submits to the project the certified test<br />

data for the sample bearings from the independent testing laboratory with the<br />

bearing manufacturer’s certified test data for the elastomer, base plate, steel<br />

laminates, <strong>and</strong> pro<strong>of</strong> load.<br />

711.24 Waterpro<strong>of</strong>ing Fabric. Furnish waterpro<strong>of</strong>ing fabric according to<br />

ASTM D 173.<br />

Furnish materials according to the <strong>Department</strong>’s Qualified products List (QPL).<br />

711.25 Type 2 Membrane Waterpro<strong>of</strong>ing.<br />

Physical Properties<br />

Thickness ASTM D 1777 60 mils (1500 µm) min.<br />

Width 36 inches (914 mm) min.<br />

Pliability [180° bend over 1/4 inch (6 mm)<br />

m<strong>and</strong>rel @ -25 °F (-32 °C)] ASTM D 146<br />

No Effect<br />

Elongation ASTM D 412 (Die C)<br />

Puncture Resistance-Membrane<br />

300% min<br />

ASTM E 154<br />

Permeance (Grains/ft<br />

40 lb (18 kg) min.<br />

2 /hr/in Hg)<br />

ASTM E 96, Method B 0.1 max.<br />

Water Absorption (% by Weight) ASTM D 570 0.2 max.<br />

Adhesion to concrete ASTM D 903 5.0 min.<br />

Submit certified test data <strong>and</strong> letter <strong>of</strong> certification to the Engineer.<br />

Furnish materials according to the <strong>Department</strong>’s Qualified Products List (QPL).<br />

711.26 Structural Timber, Lumber <strong>and</strong> Piling. Furnish structural timber,<br />

lumber <strong>and</strong> piling according to 712.06, <strong>and</strong> AASHTO M 168, with the following<br />

modification:<br />

762

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!